Loading...
ST9902-SP130625�ywai4% 1'Illl�l� Letter Of Transmittal 6/25/2013 2:16:25PM Report: 130282 Contains the Following Reports: Report Description • Submittal #11303 for Project: West Sandy Lake - Coppell • Detailed Data for Submittal #11303 • Backup Data for Mix:8272 of Submittal #11303 for Project: West Sandy Lake - Coppell • Backup Data for Mix:8274 of Submittal #11303 for Project: West Sandy Lake - Coppell • Backup Data for Mix:8293 of Submittal #11303 for Project: West Sandy Lake - Coppell • Bridgeport Man Sand (June 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell • Cement Mill Cretificate (April 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell • Bridgeport Stone (June 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell • Bridgeport Stone Type D (June 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell • Trinity Pea Gravel (February 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell • TXI Concrete Sand (June 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell • MB -AE 90 (January 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell • Pozzolith 100XR (January 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell 1992 - 2013 Digital Site Systems, Inc. Page I Quadrel iService S June 25, 2013 Axis Contracting, Inc. P.O. Box 360715 Dallas TX. 75336 -0715 Attn: Mr. Chris Quentin RE: West Sandy Lake - Coppell Mix Code Numbers 8272, 8274, 8293 03111 "P"Pa°e"S"w '. �'""lu �o`' u�tti�d:d�u"1 v °a��^ 1. l'ablGiP +r ���'m, i'Y'v 75217 9 d 2; 6,1 Pa 671( ) °3.m The attached concrete mix designs utilizing the appropriate ASTM C -33 or ASTM C -330 aggregate are proposed for use on the above referenced project for ready -mixed concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the left hand corner of the mix design. TXI certifies that the above mix designs, when ordered by specified design identity, and delivered by TXI, will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of the ACI 318 building code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix design prior to its use. Failure to notify us prior to first placement shall constitute acceptance. To ensure that the proper mix design is ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. The information contained in this submittal is confidential and the exclusive property of TXL It cannot be copied, duplicated or disclosed to third parties without the expressed written consent of TXI. Sincerely, TXI Operations, LP Victor H. Villarreal Technical Services Manager - Q.A. /Q.C. We volll pi,ovia,e lauwil ding mate Noals„ SIE14VUCE aiiid soltak:mn,s so th,Bt CUstoinhirs CHOOSE 1 X1, 1992 - 2013 Digital Site Systems, Inc. Page 2 Quadrel iService S GENERAL NOTES & RECOMMENDATIONS The strength of structural lightweight mix designs is valid provided strength specimens are taken at the point of placement and are air cured in accordance with ASTM Test Method C 567 -05, section 7.3 except as modified in section 8.1, alternative method, ASTM Specification C 330 -05. The strength performance of structural lightweight mixes is designed on the basis of cementitious content. Water to cementitious ratio requirements are not applicable for this type of concrete. The use of air entraining in lightweight concrete is necessary in order to achieve the desired unit weight and to enhance pumpability. This shall be considered a Condition of Sale. Unless otherwise indicated, when the concrete temperature at point of placement exceeds 90 degrees Fahrenheit, TXI will guarantee the strength performance of the mix design(s) herein submitted up to a maximum placement temperature of 100 degrees Fahrenheit using an ASTM C 494 Type D retarding water - reducer, or a minimum of 20 % replacement of fly ash in combination with an ASTM C 494 Type A conventional water- reducer, as long as the concrete is placed within 75 minutes from batch time. Unless otherwise indicated, strength of plain concrete guaranteed up to a maximum placement temperature of 85 degrees Fahrenheit. Based on current market conditions, TXI does not guarantee a single source of cement, fly ash or aggregates for any project except by special advance arrangement. TXI does not guarantee the color uniformity of ready mix concrete due to: normal color variation in cement and aggregates, normal slump variation, or other conditions such as weather, placement, consolidation, curing, leakage or variations in form texture, or surface treatments. The aggregates and cements native to this region may contain trace amounts of iron which, while not visible to the naked eye, may become noticeable in the concrete through oxidation. The cement in use meets both Type I and Type II requirements of ASTM C150 for Low Alkali Portland Cement. These mix designs may contain a high volume of fly ash. Please note that the contractor and testing laboratory are responsible for ensuring the proper initial curing environment for the specimens and the cylinders should NOT be transported to the laboratory prior to 48 hours after casting. These mix designs may be considered "High- Strength Concrete ", which is concrete with required strengths of 6000 psi and greater. All high- strength mixes are designed to contain an ASTM C 494 Type F high range water reducer and a minimum fly ash replacement factor of 20 %. Please ensure that all samples are obtained from the point of placement. The contractor and testing laboratory are responsible for ensuring the proper initial curing environment for the specimens between 68 -78 degrees F. The minimum load size for high strength concrete is 4 cubic yards. These mix designs may be considered "High -Early Strength ". Test specimens used for in -place early strength determination should be cured in a manner as close as possible to the in -place concrete. Utilization of insulated blankets is highly recommended. The hydration process of Portland cement is a temperature sensitive chemical reaction, in -place concrete generally develops and maintains substantially more heat than cylinders. We suggest a maturity monitoring system such as the intelliRock system or equal for the most accurate estimation of in -place strength instead of cylinders. Cylinders for 28 day acceptance strength should be cured in strict accordance with ASTM C 31. 1992 - 2013 Digital Site Systems, Inc. Page 3 Quadrel iService S Allowable water, not to exceed the maximum water to cementitious ratio, which may be added to the concrete is identified on the delivery ticket. This will indicate the water withheld from the batch. Water added in excess of this amount will reduce the concrete strength and will be at the customer's risk. Maximum specified slump may not be exceeded regardless of the amount of water withheld. Unless otherwise prearranged, specialty non - standard testing on all concrete and /or constituent materials (aggregates) is the contractor's (buyer) responsibility and will be arranged and paid for by the contractor. This includes but is not limited to drying shrinkage, solar reflectivity index, chloride ion, slump loss curve, 3 point water to cementitious ratio curve, etc. TXI is not responsible for deficient testing of the fresh and hardened concrete specimens. When a low strength result is reported, and the applicable ASTM standards were not strictly followed: First, TXI will conduct an investigation of the production records to verify compliance and delivery ticket to determine if water was added and to verify that the concrete was placed within the allowed time frame. Second TXI may conduct an in -place evaluation of the compressive strength of the concrete in question in accordance with the Standard Test Method for Rebound Number of Hardened Concrete (ASTM C -805). If the concrete specimens were not tested in accordance to the applicable ASTM Standards, the contractor (buyer) may contract the services for coring and testing of cores at its own expense. The minimum load size for concrete containing pigments and /or ASTM C 494 Type F high range water reducers as constituent components is 4 cubic yards. Concrete mixes containing a plant added ASTM C 494 Type F high range water reducer (HRWR) are designed to be batched at a slump of 3" to 4" prior to the addition of the HRWR. The target delivery slump at the jobsite is 8" to 10 ". The acceptance slump at the jobsite is 8.0" +/- 2.0 ". In the event the concrete arrives to the jobsite with a slump of less than 8.0 ", a minimum amount of water or a fraction of the original dosage of HRWR may be added to increase the slump to an acceptable level. Concrete must not be ordered with a delivery slump of less than 8.0 inches. TXI performs two seasonal changes of admixtures. In late Spring ASTM C 494 Type A water reducing admixtures are adjusted by increasing the dosage rate, by substituting for another Type A more adequate for warmer temperatures or by substituting it for a Type D water reducing and retarding admixture. In early Fall, Type A and D admixtures are switched back to Type A admixtures for the cool weather season. The addition of any additives not supplied by TXI, including but not limited to pigments, fibers, water proofers and /or water repellents admixtures, foaming agents, air entrainersA and others, voids the warranty of the performance of the concrete. The concrete must be tested prior to the addition of any additives for the strength warranty to be valid. The contractor is responsible for determining the effects such additives have on the fresh and hardened concrete. We are enclosing all available back up data for the referenced mix design(s). If the strength information is not available, or is insufficient, confirmation tests may have to be conducted by your laboratory. 1992 - 2013 Digital Site Systems, Inc. Page 4 Quadrel iService S Pumping Recommendations for Concrete: 1. 5" minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Samples for slump and strength tests should be taken at discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout is recommended for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and /or layout configuration changes, mix design modifications may be required to assure strength and pumpability at additional cost to the contractor. 6. TXI cannot control, and is therefore not responsible for excessive loss of entrained air content when loss occurs as a result of boom configuration or free fall discharge from hose. To ensure minimum air loss when pumping, maintain a continuous flow of concrete through the entire length of pipe and do not subject concrete to free fall. 7. The term "pumpable concrete" refers to concrete which is capable of being transported through an apparatus which forces concrete to the placing position through a pipeline or hose as long as the recommendations indicated above are followed. The term "pumpable concrete" does not relate to concrete proportioned in a particular manner or containing a specific type of product. 1992 - 2013 Digital Site Systems, Inc. Page 5 Quadrel iService S TXI PROPRIETARY AND CONFIDENTIAL ves r Iglc lkVIn g , � �, r�q�ke �.1'aq M„ 0 rib °v l�) r� 17 97 &1 ?a,6 f"Ir`0' txixom Customer: Axis Contracting, Inc. Date Issued: June 25, 2013 Project: West Sandy Lake - Coppell Plant: 141 Lewisville 8272 5 5.00SKADMIX /AEA 1 "CS Class "A" Sidewalks, Barrier Free Ramps, Retaining Walls SSD Weight (Ib) Type I /II Cement 4 470 1" - 44 Crushed Stone 1 1340 3 /8 "CS 5 500 Concrete Sand 9 975 Stone Sand 4 418 City Water 2 258 MB -AE 90 0 0.3 to 4.0 oz /cwt CM Pozzolith 100XR 2 2.0 to 4.0 oz /cwt CM Specified F'c : 3 3,000 psi @ 28 days T TOTAL 3 3961 NOTES: TXI has no knowledge or authority regarding where this mix is to be placed (if other than the defined use on page 1), therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the above designed mix parameters of compressive strength, water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions (le. ACI -318 sections 4.1 -4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C -31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and /or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXL Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992 - 2013 Digital Site Systems, Inc. Page 6 Quadrel iService S M P� �IIIIUg��� 1 Date: 6/25/2013 Mix Name: 8272 Units : US Mix Strength: 3,000 PSI at 28 Days 1992 - 2013 Digital Site Systems, Inc. Page J Quadrel iService S STRENGTH SUMMARY, Compression 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 4.95 4.57 4710 4710 28 600 3890 DETAILED STRENGTH, Compression 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 146 5.00 4.00 4050 4050 28 146 5.00 4.00 3830 3830 28 146 5.00 4.50 5000 5000 28 4290 146 5.00 4.50 4600 4600 28 4480 146 5.00 4.50 5950 5950 28 5180 146 5.50 4.00 4010 4010 28 4860 146 4.50 3.40 5470 5470 28 5140 131 4.00 4.70 5040 5040 28 4840 146 5.00 4.00 5210 5210 28 5240 128 4.00 4.80 5490 5490 28 5250 146 6.00 5.00 5850 5850 28 5520 138 3.25 6.00 5840 5840 28 5730 141 5.00 6.50 4280 4280 28 5320 150 6.00 4.80 3820 3820 28 4650 143 5.00 5.00 4840 4840 28 4310 146 5.00 6.00 3840 3840 28 4170 146 5.00 5.50 5170 5170 28 4620 146 5.00 5.60 4360 4360 28 4460 150 3.50 5.50 4940 4940 28 4820 150 5.00 4.60 4240 4240 28 4510 150 4.25 4.50 4360 4360 28 4510 150 4.00 4.20 4710 4710 28 4440 146 4.00 4.00 4460 4460 28 4510 146 5.00 4.50 4730 4730 28 4630 122 6.50 3.60 4620 4620 28 4600 145 6.75 3.30 4160 4160 28 4500 145 6.75 3.40 4590 4590 28 4460 131 4.50 4.30 4600 4600 28 4450 131 5.00 5.00 4410 4410 28 4530 146 5.00 3.50 4810 4810 28 4610 1992 - 2013 Digital Site Systems, Inc. Page J Quadrel iService S TXI PROPRIETARY AND CONFIDENTIAL 75 �,17 97 6`17,671(,X) ' i ' Mm Customer: Axis Contracting, Inc. Date Issued: June 25, 2013 Project: West Sandy Lake - Coppell Plant: 141 Lewisville 8274 6 6.00SKADMIX /AEA 1 "CS Class "C" Driveways, Flume, Curb & Gutter SSD Weight (Ib) Type I /II Cement 5 564 1" - 44 Crushed Stone 1 1340 3 /8 "CS 5 500 Concrete Sand 9 917 Stone Sand 3 393 City Water 2 258 MB -AE 90 0 0.3 to 4.0 oz /cwt CM Pozzolith 100XR 2 2.0 to 4.0 oz /cwt CM Specified F'c : 4 4,000 psi @ 28 days T TOTAL 3 3973 NOTES: TXI has no knowledge or authority regarding where this mix is to be placed (if other than the defined use on page 1), therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the above designed mix parameters of compressive strength, water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions (le. ACI -318 sections 4.1 -4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C -31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and /or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXL Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992 - 2013 Digital Site Systems, Inc. Page 8 Quadrel iService S M P� �IIIIUg��� 1 Date: 6/25/2013 Mix Name: 8274 Units : US Mix Strength: 4,000 PSI at 28 Days 1992 - 2013 Digital Site Systems, Inc. Page 9 Quadrel iService S STRENGTH SUMMARY, Compression 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 4.73 4.41 5320 5320 28 500 4670 DETAILED STRENGTH, Compression 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 140 4.75 3.90 5080 5080 28 143 6.50 3.30 5120 5120 28 128 4.00 4.50 5220 5220 28 5140 128 7.50 6.10 5130 5130 28 5160 150 5.00 4.50 5350 5350 28 5230 128 7.50 5.80 4700 4700 28 5060 128 7.00 4490 4490 28 4850 128 5.00 4.10 5350 5350 28 4850 128 5.50 5.10 4940 4940 28 4930 140 4.50 4.90 5200 5200 28 5160 128 3.50 4.50 5740 5740 28 5290 128 3.25 4.00 5830 5830 28 5590 128 5.00 5320 5320 28 5630 140 2.50 3.10 5630 5630 28 5590 131 5.00 5.90 5240 5240 28 5390 131 5.25 3.40 6030 6030 28 5630 140 5.00 4.70 5070 5070 28 5450 122 4.00 4.30 5500 5500 28 5530 122 5.00 4.30 5020 5020 28 5200 122 4.00 4.90 4780 4780 28 5100 122 4.50 4.80 6060 6060 28 5290 131 3.00 3.70 6780 6780 28 5870 131 4.50 5.30 5470 5470 28 6100 150 4.00 3.30 5180 5180 28 5810 122 4.00 3.60 4470 4470 28 5040 150 4.00 4.30 5760 5760 28 5130 143 4.25 3.80 5920 5920 28 5380 131 5.00 4.00 5230 5230 28 5630 141 4.50 4.60 5200 5200 28 5450 141 4.50 4.80 4810 4810 28 5080 1992 - 2013 Digital Site Systems, Inc. Page 9 Quadrel iService S TXI PROPRIETARY AND CONFIDENTIAL 75 �,17 97 6`17,671(,X) ' i ' Mm Customer: Axis Contracting, Inc. Date Issued: June 25, 2013 Project: West Sandy Lake - Coppell Plant: 141 Lewisville 8293 6 6.50SK ADMIX /AEA 3 /8 "PG Class "C" Driveway SSD Weight (Ib) Type I /II Cement 6 611 3/8" - 410 Pea Gravel 1 1680 Concrete Sand 9 927 Stone Sand 3 397 City Water 2 296 MB -AE 90 0 0.3 to 4.0 oz /cwt CM Pozzolith 100XR 2 2.0 to 4.0 oz /cwt CM Specified F'c : 4 4,000 psi @ 28 days T TOTAL 3 3911 NOTES: TXI has no knowledge or authority regarding where this mix is to be placed (if other than the defined use on page 1), therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the above designed mix parameters of compressive strength, water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions (le. ACI -318 sections 4.1 -4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C -31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and /or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXL Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992 - 2013 Digital Site Systems, Inc. Page 10 Quadrel iService S M P� �IIIIUg��� 1 Date: 6/25/2013 Mix Name: 8293 Units : US Mix Strength: 4,000 PSI at 28 Days 1992 - 2013 Digital Site Systems, Inc. Page 11 Quadrel iService S STRENGTH SUMMARY, Compression 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 4.25 4.41 5370 5370 28 750 5250 DETAILED STRENGTH, Compression 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 122 4.00 4.30 5500 5500 28 122 4.50 4.80 6060 6060 28 150 5.00 3.30 5270 5270 28 5610 138 5.00 4.20 3430 3430 28 4920 131 3.00 3.70 6780 6780 28 5160 131 4.50 5.30 5470 5470 28 5230 150 4.00 3.30 5180 5180 28 5810 122 4.00 3.60 4470 4470 28 5040 150 4.00 4.30 5760 5760 28 5130 150 3.00 5.00 5840 5840 28 5350 150 5.00 6.00 4980 4980 28 5520 150 4.00 5.50 5440 5440 28 5420 143 4.00 3.30 7100 7100 28 5840 150 5.00 5.30 5080 5080 28 5870 143 4.25 3.80 5920 5920 28 6030 150 3.25 4.50 6000 6000 28 5670 150 5.00 5.50 5780 5780 28 5900 150 5.00 5.30 4950 4950 28 5580 150 4.25 5.50 4870 4870 28 5200 131 5.00 4.00 5230 5230 28 5010 150 4.00 5.20 5340 5340 28 5150 150 4.00 4.20 5270 5270 28 5280 138 3.25 4.70 6400 6400 28 5670 146 4.75 4.00 6070 6070 28 5910 122 4.50 4.00 5120 5120 28 5860 145 4.00 2.90 4830 4830 28 5340 141 4.50 4.60 5200 5200 28 5050 141 4.50 4.80 4810 4810 28 4950 122 4.75 3.75 4700 4700 28 4900 122 3.50 3.70 4300 4300 28 4600 1992 - 2013 Digital Site Systems, Inc. Page 11 Quadrel iService S TXI corp. Bridgeport Stone Plant Technical Services Lab P.O. Box 487 Phone: 972 - 647 -7232 Bridgeport, Texas 76426 Fax: 972 - 647-7244 LiuL»Ituu��ii�iuOYr °� DATE June 10, 2013 COMPANY /NAME MATERIAL Mfg Sand TEST RESULTS SIEVE SIZE WT. RETAINED % PASSING SPECIFICATION U. S. METRIC ASTM D 4791 Flat & Elongated N/A Tx Dot 413 -A 3/8" 9.5mm 0 100.0 80 100 #4 4.75mm 11.5 98.6 95 100 #8 2.36mm 165.1 80.0 80 100 #16 1.16mm 412 50.1 50 85 #30 .600mm 582.8 29.4 25 60 #50 .300mm 715.8 13.3 10 30 #100 .150mm 793.4 3.9 0 10 #200 .075mm 813.2 1.5 0 3 TOTAL WEIGHT 825.6 SPECIFIC TEST RESULTS Tx Dot 403 -A Specific Gravity(SSD) 2.62 Tx Dot 403 -A Absorption 1.2 ASTM D 4791 Flat & Elongated N/A Tx Dot 413 -A Clay Lumps N/A Tx Dot 203 -F Sand Equivalent 80 Tx Dot 411 -A Magnesium Soundness 12 Sodium Soundness 1 Unit Weight: Dry Loose 99.7 LB. /CF. Dry Rodded 110.7 LB. /CF. Fineness Modulus 3.247 Ben Jones Txi Representative MIDLOTHIAN CEMENT 245 Ward Road • Midlothian, Texas 76065 • 972.775.3449 • www.txi.eom Bin Number: I Car Number Sample Date: Aoril -2013 Monthlv Averar Chemical Requirements; Spec. Limit Test Result Si02, ( %) A 20.2 A1203, ( %) 6.0 max 4.2 Fe203, ( %j 6.0 max 3.3 CaO, ( %) A 64,3 M90, ( %) 6.0 max 1.3 S03,(%) 3.0 max 2,7 Lass on Ignition, ( %) 3.0 max 1.9 Insoluble Residue, ( %) 0.75 max 0.32 CO2, ( %) A 1.1 Limestone, ( %) 5.0 max 2.8 CaCO3 in limestone, ( %) 70 min 91 Potential phase composition, ( %):B C3S A 62 C2S A 11 C3A 8 Max 5 C4AF A 10 C3S } 4.75(03A) 100 max 87 Spec. Test Optional' Chemical Requirements: Limit Result Total Alkalies (Na20 equiv.), ( %) 0.60 max 0.55 A Not Applicable. e Adjusted for limestone per A1.6 Time of Setting: Vicat initial set, minutes 45 min 104 375 max 104 Compressive strengths, (Mpa) 3 days SPECIFICATIONS 7 days Portland Cement Compressive strengths, (psi) Tons: Type 1l11 (Low Alkali) 1740 min 3732 A.S.T.M 0150 -11 2760 min 4479 Spec. Test Physical Requirements: Limit Result Air Content, Volume, ( %) 12 max g Average Fineness (Blaine), (m2/kg) 280 min 374 420 max Autoclave Expansion, ( %) 0.80 max -0.01 Time of Setting: Vicat initial set, minutes 45 min 104 375 max 104 Compressive strengths, (Mpa) 3 days 12.0 min 25.7 7 days 19.0 min 30.7 Compressive strengths, (psi) 3 days 1740 min 3732 7 days 2760 min 4479 We Certify that the above described cement, at the time of shipment meets the chemical and physical requirements of ASTM C - 150 specification. Signature: Date: Title: Quaff y Services Manager 5113113 TOTAL WEIGHT 29.5 SPECIFIC TEST RESULTS Tx Dot 403 -A Specific Gravity(SSD) TXI corp. Tx Dot 403 -A Absorption 1 Tx Dot 410 -A L A Abrasion Bridgeport Stone Plant Tx Dot 413 -A Technical Services Lab 0 Tx Dot 406 -A Decantation P.O. Box 487 Phone: 972 - 647 -7232 "�i�»IIUUI,�'lIlUOYr °� .. .. ._ .. Bridgeport, Texas 76426 Fax: 972 - 647-7244 DATE June 10, 2013 COMPANY NAME MATERIAL 1" - #4 Class A ASTM C 33 #57 TxDOT Item 421 Grade 4 TEST RESULTS SIEVE SIZE WT. RETAINED % PASSING SPECIFICATION U. S. METRIC 11/2" 37.5mm 0 100.0 100 1" 25.Omm 1 96.6 95 100 3/4" 19.Omm 6.7 77.3 (60 90) 1/2" 12.5mm 17.3 41.4 25 60 3/8" 9.5mm 22.3 24.4 #4 4.75mm 28.1 4.7 0 10 #8 2.36mm 29.2 1.0 0 5 TOTAL WEIGHT 29.5 SPECIFIC TEST RESULTS Tx Dot 403 -A Specific Gravity(SSD) 2.66 Tx Dot 403 -A Absorption 1 Tx Dot 410 -A L A Abrasion 30 Tx Dot 413 -A Clay Lumps 0 Tx Dot 406 -A Decantation 0.5 Tx Dot 411 -A Magnesium Soundness 11 Sodium Soundness 0 Unit Weight: Dry Loose Dry Rodded Ben Jones Txi Representative 97.2 LB. /CF. 101.5 LB. /CF. TXI corp. Bridgeport Stone Plant Technical Services Lab P.O. Box 487 Phone: 972 - 647 -7232 Bridgeport, Texas 76426 Fax: 972 - 647-7244 LiuL»Ituu��ii�iuOYr °� DATE June 10, 2013 COMPANY /NAME MATERIAL Type -D TEST RESULTS SIEVE SIZE WT. RETAINED % PASSING SPECIFICATION U. S. METRIC 3/8" 9.5mm 1.2 92.6 95 100 #4 4.75mm 9.8 39.9 35 45 #8 2.36mm 15.8 3.1 0 15 #10 2mm 16 1.8 TOTAL WEIGHT 16.3 lbs. SPECIFIC TEST RESULTS Tx Dot 403 -A Specific Gravity(SSD) 2.64 Tx Dot 411 -A Magnesium Soundness 9 Sodium Soundness 0 Tx Dot 403 -A Absorption 1.4 Unit Weight: Tx Dot 410 -A L A Abrasion 28 Dry Loose 86.3 LB. /CF. Dry Rodded 94.5 LB. /CF. Tx Dot 413 -A Clay Lumps 0 Ben Jones Txi Representative `1Q 13 1 1 West. Mc ckJnglbird O aric flllaas, R xKas 75247 972.6 7.6700 700 ,% txi.cam COARSE AGGREGATE GRADATION Material. ASTM C -33 ( Grade # 8) Pea Gravel Source: Trinity Sample Date: 25- Feb -13 Time: 8:OOAM Analysis Date: 25- Feb -13 Time: 9:OOAM SIEVE Cum. Wt. Ret. % Ret. ASTM C -33 % Pass TX DOT 421.2(1) 1/2" 0.00 0.0% 0 100.0% 100 3/8" 0.34 2.2% 0-15 97.8% 85 -100 # 4 12.72 82.4% 70 -90 17.6% 1030 # 8 15.26 98.8% 90 -100 1.2% 0 -10 # 16 15.37 99.5% 95 -100 0.5% 0 -5 #VALUE! #VALUE! #VALUE! #VALUE! PAN 15.44 Decant: 0.4% SAMPLE BY. GWM ANALYSIS BY.- GWM TXI Corp. � �UI��F TECHNICAL SERVICES LAB TXI Concrete Sand PHONE: 972 - 647 -7232 4t �f l FAX 972 -647 -7244 DATE 772.2 June 10, 2013 2.499 COMPANY / NAME TXI Ready Mix SPECIFIC TEST RESULTS MATERIAL Concrete Sand TxDot 403 -A Specific Gravity(SSD) 2.63 TxDot 411 -A Magnesium Soundness TxDOT Item 421 Fine Aggregate ASTM C 33 Fine Aggregate TEST RESULTS Sodium Soundness 1 SIEVE SIZE WT. RETAINED % PASSING SPECIFICATION U. S. METRIC 3/8" 9.5mm 0.0 100.0 TxDot 612 -J 100 #4 4.75mm 19.3 97.5 95 100 #8 2.36mm 83.4 89.2 80 100 #16 1.16mm 179.9 76.7 50 85 #30 .600mm 315.1 59.2 25 65 #50 .300mm 587.6 23.9 10 35 #100 .150mm 744.4 3.6 0 10 #200 .075mm 766.7 0.7 0 3 TOTAL WEIGHT 772.2 F. M. 2.499 SPECIFIC TEST RESULTS TxDot 403 -A TxDot 403 -A Specific Gravity(SSD) 2.63 TxDot 411 -A Magnesium Soundness 8 Sodium Soundness 1 TxDot 403 -A TxDot 403 -A Absorption 0.5 Unit Weight TxDot 612 -J Tx DOT 612 -J Acid Insoluble Residue 85 Dry Loose 103.2 LB. /CF. Dry Rodded 110.2 LB. /CF. TxDot 203 -F TxDot 203 -F Sand Equivalent 87 TxDot 413 -A Deleterious Materials 0% Ben Jones TXI REPRESENTATIVE The Chemical Company January 2, 2013 TXI Operations, LP 1341 W. Mockingbird Lane Dallas, Texas 75247 Attention: Victor Villarreal Project: All Projects Project location: Various Locations Certificate of Conformance MB-AE TM 90 BASF Corporation* Air - Entraining Admixture for Concrete *(successor in interest to BASF Construction Chemicals, LLC , which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures, Inc., formerly known as Master Builders, Inc.) I, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,certify: That MB -AE 90 is a BASF Corporation Air - Entraining Admixture for concrete; and That no calcium chloride or chloride based ingredient is used in the manufacture of MB -AE 90; and That MB -AE 90, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.000068 percent (0.68 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That MB -AE 90 meets the requirements of ASTM C 260, Corps of Engineers' CRD -C 13 and AASHTO M154, the Standard Specifications for Air - Entraining Admixtures for Concrete. Richard Hubbard Sr. Technical Marketing Specialist, BASF Corporation BASF Corporation 23700 Chagrin Boulvard Master Cleveland, OH 44122 216 839 -7500 ph Builders www.masterbuilders.com Admixture Solutions The Chemical Company January 2, 2013 TXI Operations, LP 1341 W. Mockingbird Lane Dallas, Texas 75247 Attention: Victor Villarreal Project: All Projects Project location: Various Locations Certificate of Conformance Pozzolith® 100 XR BASF Corporation* Admixture for Concrete *(successor in interest to BASF Construction Chemicals, LLC , which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures, Inc., formerly known as Master Builders, Inc.) I, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,certify: That Pozzolith 100 XR is a BASF Corporation Set Retarding Admixture for concrete; and That no calcium chloride or chloride based ingredient is used in the manufacture of Pozzolith 100 XR; and That Pozzolith 100 XR, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.00014 percent (1.4 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That Pozzolith 100 XR meets the requirements for a Type B, Retarding and Type D, Water- Reducing and Retarding Admixture specified in ASTM C 494, Corps of Engineers' CRD -C 87 and AASHTO M194, the Standard Specifications for Chemical Admixtures for Concrete. Richard Hubbard Sr. Technical Marketing Specialist, BASF Corporation BASF Corporation 23700 Chagrin Boulvard Master Cleveland, OH 44122 216 839 -7500 ph Builders www.masterbuilders.com Admixture Solutions