Letter Of Transmittal
6/25/2013
2:16:25PM
Report: 130282 Contains the Following Reports:
Report Description
• Submittal #11303 for Project: West Sandy Lake - Coppell
• Detailed Data for Submittal #11303
• Backup Data for Mix:8272 of Submittal #11303 for Project: West Sandy Lake - Coppell
• Backup Data for Mix:8274 of Submittal #11303 for Project: West Sandy Lake - Coppell
• Backup Data for Mix:8293 of Submittal #11303 for Project: West Sandy Lake - Coppell
• Bridgeport Man Sand (June 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell
• Cement Mill Cretificate (April 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell
• Bridgeport Stone (June 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell
• Bridgeport Stone Type D (June 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell
• Trinity Pea Gravel (February 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell
• TXI Concrete Sand (June 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell
• MB -AE 90 (January 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell
• Pozzolith 100XR (January 2013).pdf attachment for Submittal #11303 for Project: West Sandy Lake - Coppell
1992 - 2013 Digital Site Systems, Inc. Page I Quadrel iService
S
June 25, 2013
Axis Contracting, Inc.
P.O. Box 360715
Dallas TX. 75336 -0715
Attn: Mr. Chris Quentin
RE: West Sandy Lake - Coppell
Mix Code Numbers
8272, 8274, 8293
03111 "P"Pa°e"S"w '. �'""lu �o`' u�tti�d:d�u"1 v °a��^ 1. l'ablGiP +r ���'m, i'Y'v 75217 9 d 2; 6,1 Pa 671( )
°3.m
The attached concrete mix designs utilizing the appropriate ASTM C -33 or ASTM C -330 aggregate are
proposed for use on the above referenced project for ready -mixed concrete to be furnished by TXI.
To ensure that the correct mix is delivered to your project, please order by the mix design number which
appears in the left hand corner of the mix design.
TXI certifies that the above mix designs, when ordered by specified design identity, and delivered by TXI, will
meet or exceed the indicated design strength at the designated age when tested in accordance with the
applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and
evaluated in accordance with applicable provisions of the ACI 318 building code.
TXI would like to be included on your mailing list to receive all test reports. ASTM C 94 entitles a
manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance.
Contact us if you have any questions or require any additional information. Please notify TXI of approval of the
proposed mix design prior to its use. Failure to notify us prior to first placement shall constitute acceptance. To
ensure that the proper mix design is ordered, please send a copy of this letter, after approval, to the above
referenced project to be used by the person ordering the concrete for this job.
The information contained in this submittal is confidential and the exclusive property of TXL It cannot be
copied, duplicated or disclosed to third parties without the expressed written consent of TXI.
Sincerely,
TXI Operations, LP
Victor H. Villarreal
Technical Services Manager - Q.A. /Q.C.
We volll pi,ovia,e lauwil ding mate Noals„
SIE14VUCE aiiid soltak:mn,s so th,Bt CUstoinhirs CHOOSE 1 X1,
1992 - 2013 Digital Site Systems, Inc. Page 2 Quadrel iService
S
GENERAL NOTES & RECOMMENDATIONS
The strength of structural lightweight mix designs is valid provided strength specimens are taken at
the point of placement and are air cured in accordance with ASTM Test Method C 567 -05, section
7.3 except as modified in section 8.1, alternative method, ASTM Specification C 330 -05. The
strength performance of structural lightweight mixes is designed on the basis of cementitious content.
Water to cementitious ratio requirements are not applicable for this type of concrete. The use of air
entraining in lightweight concrete is necessary in order to achieve the desired unit weight and to
enhance pumpability. This shall be considered a Condition of Sale.
Unless otherwise indicated, when the concrete temperature at point of placement exceeds 90 degrees
Fahrenheit, TXI will guarantee the strength performance of the mix design(s) herein submitted up to a
maximum placement temperature of 100 degrees Fahrenheit using an ASTM C 494 Type D retarding
water - reducer, or a minimum of 20 % replacement of fly ash in combination with an ASTM C 494
Type A conventional water- reducer, as long as the concrete is placed within 75 minutes from batch
time. Unless otherwise indicated, strength of plain concrete guaranteed up to a maximum placement
temperature of 85 degrees Fahrenheit.
Based on current market conditions, TXI does not guarantee a single source of cement, fly ash or
aggregates for any project except by special advance arrangement.
TXI does not guarantee the color uniformity of ready mix concrete due to: normal color variation in
cement and aggregates, normal slump variation, or other conditions such as weather, placement,
consolidation, curing, leakage or variations in form texture, or surface treatments.
The aggregates and cements native to this region may contain trace amounts of iron which, while not
visible to the naked eye, may become noticeable in the concrete through oxidation.
The cement in use meets both Type I and Type II requirements of ASTM C150 for Low Alkali
Portland Cement.
These mix designs may contain a high volume of fly ash. Please note that the contractor and testing
laboratory are responsible for ensuring the proper initial curing environment for the specimens and
the cylinders should NOT be transported to the laboratory prior to 48 hours after casting.
These mix designs may be considered "High- Strength Concrete ", which is concrete with required
strengths of 6000 psi and greater. All high- strength mixes are designed to contain an ASTM C 494
Type F high range water reducer and a minimum fly ash replacement factor of 20 %. Please ensure
that all samples are obtained from the point of placement. The contractor and testing laboratory are
responsible for ensuring the proper initial curing environment for the specimens between 68 -78
degrees F. The minimum load size for high strength concrete is 4 cubic yards.
These mix designs may be considered "High -Early Strength ". Test specimens used for in -place early
strength determination should be cured in a manner as close as possible to the in -place concrete.
Utilization of insulated blankets is highly recommended. The hydration process of Portland cement is
a temperature sensitive chemical reaction, in -place concrete generally develops and maintains
substantially more heat than cylinders. We suggest a maturity monitoring system such as the
intelliRock system or equal for the most accurate estimation of in -place strength instead of cylinders.
Cylinders for 28 day acceptance strength should be cured in strict accordance with ASTM C 31.
1992 - 2013 Digital Site Systems, Inc. Page 3 Quadrel iService
S
Allowable water, not to exceed the maximum water to cementitious ratio, which may be added to the
concrete is identified on the delivery ticket. This will indicate the water withheld from the batch.
Water added in excess of this amount will reduce the concrete strength and will be at the customer's
risk. Maximum specified slump may not be exceeded regardless of the amount of water withheld.
Unless otherwise prearranged, specialty non - standard testing on all concrete and /or constituent
materials (aggregates) is the contractor's (buyer) responsibility and will be arranged and paid for by
the contractor. This includes but is not limited to drying shrinkage, solar reflectivity index, chloride
ion, slump loss curve, 3 point water to cementitious ratio curve, etc.
TXI is not responsible for deficient testing of the fresh and hardened concrete specimens. When a low
strength result is reported, and the applicable ASTM standards were not strictly followed: First, TXI
will conduct an investigation of the production records to verify compliance and delivery ticket to
determine if water was added and to verify that the concrete was placed within the allowed time
frame. Second TXI may conduct an in -place evaluation of the compressive strength of the concrete in
question in accordance with the Standard Test Method for Rebound Number of Hardened Concrete
(ASTM C -805). If the concrete specimens were not tested in accordance to the applicable ASTM
Standards, the contractor (buyer) may contract the services for coring and testing of cores at its own
expense.
The minimum load size for concrete containing pigments and /or ASTM C 494 Type F high range
water reducers as constituent components is 4 cubic yards.
Concrete mixes containing a plant added ASTM C 494 Type F high range water reducer (HRWR) are
designed to be batched at a slump of 3" to 4" prior to the addition of the HRWR. The target delivery
slump at the jobsite is 8" to 10 ". The acceptance slump at the jobsite is 8.0" +/- 2.0 ". In the event the
concrete arrives to the jobsite with a slump of less than 8.0 ", a minimum amount of water or a
fraction of the original dosage of HRWR may be added to increase the slump to an acceptable level.
Concrete must not be ordered with a delivery slump of less than 8.0 inches.
TXI performs two seasonal changes of admixtures. In late Spring ASTM C 494 Type A water
reducing admixtures are adjusted by increasing the dosage rate, by substituting for another Type A
more adequate for warmer temperatures or by substituting it for a Type D water reducing and
retarding admixture. In early Fall, Type A and D admixtures are switched back to Type A admixtures
for the cool weather season.
The addition of any additives not supplied by TXI, including but not limited to pigments, fibers,
water proofers and /or water repellents admixtures, foaming agents, air entrainersA and others, voids
the warranty of the performance of the concrete. The concrete must be tested prior to the addition of
any additives for the strength warranty to be valid. The contractor is responsible for determining the
effects such additives have on the fresh and hardened concrete.
We are enclosing all available back up data for the referenced mix design(s). If the strength
information is not available, or is insufficient, confirmation tests may have to be conducted by
your laboratory.
1992 - 2013 Digital Site Systems, Inc. Page 4 Quadrel iService
S
Pumping Recommendations for Concrete:
1. 5" minimum diameter lines with no reduction to smaller lines.
2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as
possible.
3. Samples for slump and strength tests should be taken at discharge end of hose for strength
guarantee to be valid.
4. To prime pump lines, a minimum of 8.0 sack grout is recommended for lubrication. In the case of
strength concrete, equivalent strength grout should be used if the grout remains in the placement.
5. Pump mixes are based on minimum cement content pumped at ground level. As pump line
increases in length or height and /or layout configuration changes, mix design modifications may be
required to assure strength and pumpability at additional cost to the contractor.
6. TXI cannot control, and is therefore not responsible for excessive loss of entrained air content
when loss occurs as a result of boom configuration or free fall discharge from hose. To ensure
minimum air loss when pumping, maintain a continuous flow of concrete through the entire length of
pipe and do not subject concrete to free fall.
7. The term "pumpable concrete" refers to concrete which is capable of being transported through an
apparatus which forces concrete to the placing position through a pipeline or hose as long as the
recommendations indicated above are followed. The term "pumpable concrete" does not relate to
concrete proportioned in a particular manner or containing a specific type of product.
1992 - 2013 Digital Site Systems, Inc. Page 5 Quadrel iService
S
TXI PROPRIETARY AND CONFIDENTIAL
ves r Iglc lkVIn g , � �, r�q�ke �.1'aq M„ 0 rib °v l�) r� 17 97 &1 ?a,6 f"Ir`0'
txixom
Customer: Axis Contracting, Inc. Date Issued: June 25, 2013
Project: West Sandy Lake - Coppell Plant: 141
Lewisville
8272 5
5.00SKADMIX /AEA 1 "CS
Class "A" Sidewalks, Barrier Free Ramps, Retaining Walls
SSD Weight (Ib)
Type I /II Cement 4
470
1" - 44 Crushed Stone 1
1340
3 /8 "CS 5
500
Concrete Sand 9
975
Stone Sand 4
418
City Water 2
258
MB -AE 90 0
0.3 to 4.0 oz /cwt CM
Pozzolith 100XR 2
2.0 to 4.0 oz /cwt CM
Specified F'c : 3
3,000 psi @ 28 days T
TOTAL 3
3961
NOTES:
TXI has no knowledge or authority regarding where this mix is to be placed (if other than the defined use on
page 1), therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the
above designed mix parameters of compressive strength, water cement ratio, cement content, and air content,
are appropriate for the anticipated environmental conditions (le. ACI -318 sections 4.1 -4.3, and the local
Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and
Section 1.6.3., and per ASTM C -31.
Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the
right to adjust these dosages to meet the changes in jobsite demands.
This mix has been designed to meet the requirements of the documents received from the project, and /or your
verbal request. Aggregate weights may change depending on gradations or specific gravity of material.
Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXL Any use or
dissemination without permission is a violation of federal criminal law.
COMMENTS:
1992 - 2013 Digital Site Systems, Inc.
Page 6
Quadrel iService S M
P�
�IIIIUg��� 1
Date: 6/25/2013
Mix Name: 8272
Units : US
Mix Strength: 3,000 PSI at 28 Days
1992 - 2013 Digital Site Systems, Inc. Page J Quadrel iService
S
STRENGTH SUMMARY,
Compression
6" x 12"
Strengths
No. Of
Avg
Avg
Avg 28
Avg Acc
Accept
Std ACI318
Tests
Slump
Air
Day
Age
Age
Dev Req'd
30
4.95
4.57
4710
4710
28
600 3890
DETAILED STRENGTH, Compression
6"
x 12"
Plant
Slump
Air
Strengths
Acc
Acc Age
28 Day Acc Age
Age
Run Avg 3
146
5.00
4.00
4050
4050
28
146
5.00
4.00
3830
3830
28
146
5.00
4.50
5000
5000
28
4290
146
5.00
4.50
4600
4600
28
4480
146
5.00
4.50
5950
5950
28
5180
146
5.50
4.00
4010
4010
28
4860
146
4.50
3.40
5470
5470
28
5140
131
4.00
4.70
5040
5040
28
4840
146
5.00
4.00
5210
5210
28
5240
128
4.00
4.80
5490
5490
28
5250
146
6.00
5.00
5850
5850
28
5520
138
3.25
6.00
5840
5840
28
5730
141
5.00
6.50
4280
4280
28
5320
150
6.00
4.80
3820
3820
28
4650
143
5.00
5.00
4840
4840
28
4310
146
5.00
6.00
3840
3840
28
4170
146
5.00
5.50
5170
5170
28
4620
146
5.00
5.60
4360
4360
28
4460
150
3.50
5.50
4940
4940
28
4820
150
5.00
4.60
4240
4240
28
4510
150
4.25
4.50
4360
4360
28
4510
150
4.00
4.20
4710
4710
28
4440
146
4.00
4.00
4460
4460
28
4510
146
5.00
4.50
4730
4730
28
4630
122
6.50
3.60
4620
4620
28
4600
145
6.75
3.30
4160
4160
28
4500
145
6.75
3.40
4590
4590
28
4460
131
4.50
4.30
4600
4600
28
4450
131
5.00
5.00
4410
4410
28
4530
146
5.00
3.50
4810
4810
28
4610
1992 - 2013 Digital Site Systems, Inc. Page J Quadrel iService
S
TXI PROPRIETARY AND CONFIDENTIAL
75 �,17 97 6`17,671(,X) '
i ' Mm
Customer: Axis Contracting, Inc. Date Issued: June 25, 2013
Project: West Sandy Lake - Coppell Plant: 141
Lewisville
8274 6
6.00SKADMIX /AEA 1 "CS
Class "C" Driveways, Flume, Curb & Gutter
SSD Weight (Ib)
Type I /II Cement 5
564
1" - 44 Crushed Stone 1
1340
3 /8 "CS 5
500
Concrete Sand 9
917
Stone Sand 3
393
City Water 2
258
MB -AE 90 0
0.3 to 4.0 oz /cwt CM
Pozzolith 100XR 2
2.0 to 4.0 oz /cwt CM
Specified F'c : 4
4,000 psi @ 28 days T
TOTAL 3
3973
NOTES:
TXI has no knowledge or authority regarding where this mix is to be placed (if other than the defined use on
page 1), therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the
above designed mix parameters of compressive strength, water cement ratio, cement content, and air content,
are appropriate for the anticipated environmental conditions (le. ACI -318 sections 4.1 -4.3, and the local
Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and
Section 1.6.3., and per ASTM C -31.
Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the
right to adjust these dosages to meet the changes in jobsite demands.
This mix has been designed to meet the requirements of the documents received from the project, and /or your
verbal request. Aggregate weights may change depending on gradations or specific gravity of material.
Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXL Any use or
dissemination without permission is a violation of federal criminal law.
COMMENTS:
1992 - 2013 Digital Site Systems, Inc.
Page 8
Quadrel iService S M
P�
�IIIIUg��� 1
Date: 6/25/2013
Mix Name: 8274
Units : US
Mix Strength: 4,000 PSI at 28 Days
1992 - 2013 Digital Site Systems, Inc. Page 9 Quadrel iService
S
STRENGTH SUMMARY,
Compression
6" x 12"
Strengths
No. Of
Avg
Avg
Avg 28
Avg Acc
Accept
Std ACI318
Tests
Slump
Air
Day
Age
Age
Dev Req'd
30
4.73
4.41
5320
5320
28
500 4670
DETAILED STRENGTH, Compression
6"
x 12"
Plant
Slump
Air
Strengths
Acc
Acc Age
28 Day Acc Age
Age
Run Avg 3
140
4.75
3.90
5080
5080
28
143
6.50
3.30
5120
5120
28
128
4.00
4.50
5220
5220
28
5140
128
7.50
6.10
5130
5130
28
5160
150
5.00
4.50
5350
5350
28
5230
128
7.50
5.80
4700
4700
28
5060
128
7.00
4490
4490
28
4850
128
5.00
4.10
5350
5350
28
4850
128
5.50
5.10
4940
4940
28
4930
140
4.50
4.90
5200
5200
28
5160
128
3.50
4.50
5740
5740
28
5290
128
3.25
4.00
5830
5830
28
5590
128
5.00
5320
5320
28
5630
140
2.50
3.10
5630
5630
28
5590
131
5.00
5.90
5240
5240
28
5390
131
5.25
3.40
6030
6030
28
5630
140
5.00
4.70
5070
5070
28
5450
122
4.00
4.30
5500
5500
28
5530
122
5.00
4.30
5020
5020
28
5200
122
4.00
4.90
4780
4780
28
5100
122
4.50
4.80
6060
6060
28
5290
131
3.00
3.70
6780
6780
28
5870
131
4.50
5.30
5470
5470
28
6100
150
4.00
3.30
5180
5180
28
5810
122
4.00
3.60
4470
4470
28
5040
150
4.00
4.30
5760
5760
28
5130
143
4.25
3.80
5920
5920
28
5380
131
5.00
4.00
5230
5230
28
5630
141
4.50
4.60
5200
5200
28
5450
141
4.50
4.80
4810
4810
28
5080
1992 - 2013 Digital Site Systems, Inc. Page 9 Quadrel iService
S
TXI PROPRIETARY AND CONFIDENTIAL
75 �,17 97 6`17,671(,X) '
i ' Mm
Customer: Axis Contracting, Inc. Date Issued: June 25, 2013
Project: West Sandy Lake - Coppell Plant: 141
Lewisville
8293 6
6.50SK ADMIX /AEA 3 /8 "PG
Class "C" Driveway
SSD Weight (Ib)
Type I /II Cement 6
611
3/8" - 410 Pea Gravel 1
1680
Concrete Sand 9
927
Stone Sand 3
397
City Water 2
296
MB -AE 90 0
0.3 to 4.0 oz /cwt CM
Pozzolith 100XR 2
2.0 to 4.0 oz /cwt CM
Specified F'c : 4
4,000 psi @ 28 days T
TOTAL 3
3911
NOTES:
TXI has no knowledge or authority regarding where this mix is to be placed (if other than the defined use on
page 1), therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the
above designed mix parameters of compressive strength, water cement ratio, cement content, and air content,
are appropriate for the anticipated environmental conditions (le. ACI -318 sections 4.1 -4.3, and the local
Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and
Section 1.6.3., and per ASTM C -31.
Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the
right to adjust these dosages to meet the changes in jobsite demands.
This mix has been designed to meet the requirements of the documents received from the project, and /or your
verbal request. Aggregate weights may change depending on gradations or specific gravity of material.
Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXL Any use or
dissemination without permission is a violation of federal criminal law.
COMMENTS:
1992 - 2013 Digital Site Systems, Inc.
Page 10
Quadrel iService S M
P�
�IIIIUg��� 1
Date: 6/25/2013
Mix Name: 8293
Units : US
Mix Strength: 4,000 PSI at 28 Days
1992 - 2013 Digital Site Systems, Inc. Page 11 Quadrel iService
S
STRENGTH SUMMARY,
Compression
6" x 12"
Strengths
No. Of
Avg
Avg
Avg 28
Avg Acc
Accept
Std ACI318
Tests
Slump
Air
Day
Age
Age
Dev Req'd
30
4.25
4.41
5370
5370
28
750 5250
DETAILED STRENGTH, Compression
6"
x 12"
Plant
Slump
Air
Strengths
Acc
Acc Age
28 Day Acc Age
Age
Run Avg 3
122
4.00
4.30
5500
5500
28
122
4.50
4.80
6060
6060
28
150
5.00
3.30
5270
5270
28
5610
138
5.00
4.20
3430
3430
28
4920
131
3.00
3.70
6780
6780
28
5160
131
4.50
5.30
5470
5470
28
5230
150
4.00
3.30
5180
5180
28
5810
122
4.00
3.60
4470
4470
28
5040
150
4.00
4.30
5760
5760
28
5130
150
3.00
5.00
5840
5840
28
5350
150
5.00
6.00
4980
4980
28
5520
150
4.00
5.50
5440
5440
28
5420
143
4.00
3.30
7100
7100
28
5840
150
5.00
5.30
5080
5080
28
5870
143
4.25
3.80
5920
5920
28
6030
150
3.25
4.50
6000
6000
28
5670
150
5.00
5.50
5780
5780
28
5900
150
5.00
5.30
4950
4950
28
5580
150
4.25
5.50
4870
4870
28
5200
131
5.00
4.00
5230
5230
28
5010
150
4.00
5.20
5340
5340
28
5150
150
4.00
4.20
5270
5270
28
5280
138
3.25
4.70
6400
6400
28
5670
146
4.75
4.00
6070
6070
28
5910
122
4.50
4.00
5120
5120
28
5860
145
4.00
2.90
4830
4830
28
5340
141
4.50
4.60
5200
5200
28
5050
141
4.50
4.80
4810
4810
28
4950
122
4.75
3.75
4700
4700
28
4900
122
3.50
3.70
4300
4300
28
4600
1992 - 2013 Digital Site Systems, Inc. Page 11 Quadrel iService
S
TXI corp.
Bridgeport Stone Plant Technical Services Lab
P.O. Box 487 Phone: 972 - 647 -7232
Bridgeport, Texas 76426 Fax: 972 - 647-7244
LiuL»Ituu��ii�iuOYr °�
DATE June 10, 2013
COMPANY /NAME
MATERIAL Mfg Sand
TEST RESULTS
SIEVE SIZE
WT. RETAINED
% PASSING
SPECIFICATION
U. S.
METRIC
ASTM D 4791
Flat & Elongated
N/A
Tx Dot 413 -A
3/8"
9.5mm
0
100.0
80
100
#4
4.75mm
11.5
98.6
95
100
#8
2.36mm
165.1
80.0
80
100
#16
1.16mm
412
50.1
50
85
#30
.600mm
582.8
29.4
25
60
#50
.300mm
715.8
13.3
10
30
#100
.150mm
793.4
3.9
0
10
#200
.075mm
813.2
1.5
0
3
TOTAL WEIGHT 825.6
SPECIFIC TEST RESULTS
Tx Dot 403 -A
Specific Gravity(SSD)
2.62
Tx Dot 403 -A
Absorption
1.2
ASTM D 4791
Flat & Elongated
N/A
Tx Dot 413 -A
Clay Lumps
N/A
Tx Dot 203 -F
Sand Equivalent
80
Tx Dot 411 -A
Magnesium Soundness 12
Sodium Soundness 1
Unit Weight:
Dry Loose
99.7 LB. /CF.
Dry Rodded
110.7 LB. /CF.
Fineness Modulus 3.247
Ben Jones
Txi Representative
MIDLOTHIAN CEMENT
245 Ward Road • Midlothian, Texas 76065 • 972.775.3449 • www.txi.eom
Bin Number: I Car Number
Sample Date: Aoril -2013 Monthlv Averar
Chemical Requirements;
Spec.
Limit
Test
Result
Si02, ( %)
A
20.2
A1203, ( %)
6.0 max
4.2
Fe203, ( %j
6.0 max
3.3
CaO, ( %)
A
64,3
M90, ( %)
6.0 max
1.3
S03,(%)
3.0 max
2,7
Lass on Ignition, ( %)
3.0 max
1.9
Insoluble Residue, ( %)
0.75 max
0.32
CO2, ( %)
A
1.1
Limestone, ( %)
5.0 max
2.8
CaCO3 in limestone, ( %)
70 min
91
Potential phase composition, ( %):B
C3S A 62
C2S A 11
C3A 8 Max 5
C4AF A 10
C3S } 4.75(03A) 100 max 87
Spec. Test
Optional' Chemical Requirements: Limit Result
Total Alkalies (Na20 equiv.), ( %) 0.60 max 0.55
A Not Applicable.
e Adjusted for limestone per A1.6
Time of Setting:
Vicat initial set, minutes 45 min 104
375 max 104
Compressive strengths, (Mpa)
3 days
SPECIFICATIONS
7 days
Portland Cement
Compressive strengths, (psi)
Tons:
Type 1l11 (Low Alkali)
1740 min 3732
A.S.T.M 0150 -11
2760 min 4479
Spec. Test
Physical Requirements:
Limit Result
Air Content, Volume, ( %)
12 max g
Average Fineness (Blaine), (m2/kg)
280 min 374
420 max
Autoclave Expansion, ( %)
0.80 max -0.01
Time of Setting:
Vicat initial set, minutes 45 min 104
375 max 104
Compressive strengths, (Mpa)
3 days
12.0 min 25.7
7 days
19.0 min 30.7
Compressive strengths, (psi)
3 days
1740 min 3732
7 days
2760 min 4479
We Certify that the above described cement, at the time of shipment meets the chemical
and physical requirements of ASTM C - 150 specification.
Signature:
Date:
Title: Quaff y Services Manager
5113113
TOTAL WEIGHT 29.5
SPECIFIC TEST RESULTS
Tx Dot 403 -A
Specific Gravity(SSD)
TXI corp.
Tx Dot 403 -A
Absorption
1
Tx Dot 410 -A
L A Abrasion
Bridgeport Stone Plant
Tx Dot 413 -A
Technical Services Lab
0
Tx Dot 406 -A
Decantation
P.O. Box 487
Phone: 972 - 647 -7232
"�i�»IIUUI,�'lIlUOYr °�
.. .. ._
..
Bridgeport, Texas 76426
Fax: 972 - 647-7244
DATE
June 10, 2013
COMPANY NAME
MATERIAL
1" - #4 Class A
ASTM C
33 #57
TxDOT Item 421 Grade 4
TEST RESULTS
SIEVE SIZE
WT. RETAINED
% PASSING
SPECIFICATION
U. S.
METRIC
11/2"
37.5mm
0
100.0
100
1"
25.Omm
1
96.6
95
100
3/4"
19.Omm
6.7
77.3
(60
90)
1/2"
12.5mm
17.3
41.4
25
60
3/8"
9.5mm
22.3
24.4
#4
4.75mm
28.1
4.7
0
10
#8
2.36mm
29.2
1.0
0
5
TOTAL WEIGHT 29.5
SPECIFIC TEST RESULTS
Tx Dot 403 -A
Specific Gravity(SSD)
2.66
Tx Dot 403 -A
Absorption
1
Tx Dot 410 -A
L A Abrasion
30
Tx Dot 413 -A
Clay Lumps
0
Tx Dot 406 -A
Decantation
0.5
Tx Dot 411 -A Magnesium Soundness 11
Sodium Soundness 0
Unit Weight:
Dry Loose
Dry Rodded
Ben Jones
Txi Representative
97.2 LB. /CF.
101.5 LB. /CF.
TXI corp.
Bridgeport Stone Plant Technical Services Lab
P.O. Box 487 Phone: 972 - 647 -7232
Bridgeport, Texas 76426 Fax: 972 - 647-7244
LiuL»Ituu��ii�iuOYr °�
DATE June 10, 2013
COMPANY /NAME
MATERIAL Type -D
TEST RESULTS
SIEVE SIZE WT. RETAINED
% PASSING
SPECIFICATION
U. S.
METRIC
3/8"
9.5mm
1.2
92.6
95
100
#4
4.75mm
9.8
39.9
35
45
#8
2.36mm
15.8
3.1
0
15
#10
2mm
16
1.8
TOTAL WEIGHT
16.3
lbs.
SPECIFIC TEST RESULTS
Tx Dot 403 -A
Specific Gravity(SSD)
2.64
Tx Dot 411 -A
Magnesium Soundness
9
Sodium Soundness
0
Tx Dot 403 -A
Absorption
1.4
Unit Weight:
Tx Dot 410 -A
L A Abrasion
28
Dry Loose
86.3
LB. /CF.
Dry Rodded
94.5
LB. /CF.
Tx Dot 413 -A
Clay Lumps
0
Ben Jones
Txi Representative
`1Q 13 1 1 West. Mc ckJnglbird O aric flllaas, R xKas 75247 972.6 7.6700
700
,%
txi.cam
COARSE AGGREGATE GRADATION
Material. ASTM C -33 ( Grade # 8) Pea Gravel
Source: Trinity
Sample Date:
25- Feb -13
Time:
8:OOAM
Analysis Date:
25- Feb -13
Time:
9:OOAM
SIEVE
Cum. Wt. Ret.
% Ret.
ASTM C -33
% Pass
TX DOT 421.2(1)
1/2"
0.00
0.0%
0
100.0%
100
3/8"
0.34
2.2%
0-15
97.8%
85 -100
# 4
12.72
82.4%
70 -90
17.6%
1030
# 8
15.26
98.8%
90 -100
1.2%
0 -10
# 16
15.37
99.5%
95 -100
0.5%
0 -5
#VALUE!
#VALUE!
#VALUE!
#VALUE!
PAN
15.44
Decant: 0.4%
SAMPLE BY. GWM
ANALYSIS BY.- GWM
TXI Corp.
� �UI��F TECHNICAL SERVICES LAB
TXI Concrete Sand PHONE: 972 - 647 -7232
4t �f l
FAX 972 -647 -7244
DATE
772.2
June 10, 2013
2.499
COMPANY / NAME
TXI Ready Mix
SPECIFIC TEST RESULTS
MATERIAL
Concrete Sand
TxDot 403 -A
Specific Gravity(SSD)
2.63
TxDot 411 -A
Magnesium Soundness
TxDOT Item 421 Fine Aggregate
ASTM C 33 Fine Aggregate
TEST RESULTS
Sodium Soundness
1
SIEVE SIZE
WT. RETAINED
% PASSING
SPECIFICATION
U. S.
METRIC
3/8"
9.5mm
0.0
100.0
TxDot 612 -J
100
#4
4.75mm
19.3
97.5
95
100
#8
2.36mm
83.4
89.2
80
100
#16
1.16mm
179.9
76.7
50
85
#30
.600mm
315.1
59.2
25
65
#50
.300mm
587.6
23.9
10
35
#100
.150mm
744.4
3.6
0
10
#200
.075mm
766.7
0.7
0
3
TOTAL WEIGHT
772.2
F. M.
2.499
SPECIFIC TEST RESULTS
TxDot 403 -A
TxDot 403 -A
Specific Gravity(SSD)
2.63
TxDot 411 -A
Magnesium Soundness
8
Sodium Soundness
1
TxDot 403 -A
TxDot 403 -A
Absorption
0.5
Unit Weight
TxDot 612 -J
Tx DOT 612 -J
Acid Insoluble Residue
85
Dry Loose
103.2
LB. /CF.
Dry Rodded
110.2
LB. /CF.
TxDot 203 -F
TxDot 203 -F
Sand Equivalent
87
TxDot 413 -A
Deleterious Materials
0%
Ben Jones
TXI REPRESENTATIVE
The Chemical Company
January 2, 2013
TXI Operations, LP
1341 W. Mockingbird Lane
Dallas, Texas 75247
Attention: Victor Villarreal
Project: All Projects
Project location: Various Locations
Certificate of Conformance
MB-AE TM 90
BASF Corporation* Air - Entraining Admixture for Concrete
*(successor in interest to BASF Construction Chemicals, LLC , which is successor by merger to BASF Admixtures,
Inc., formerly known as Degussa Admixtures, Inc., formerly known as Master Builders, Inc.)
I, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,certify:
That MB -AE 90 is a BASF Corporation Air - Entraining Admixture for concrete; and
That no calcium chloride or chloride based ingredient is used in the manufacture of MB -AE 90; and
That MB -AE 90, based on the chlorides originating from all the ingredients used in its manufacture, contributes less
than 0.000068 percent (0.68 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg
(1 fluid ounce per 100 pounds) of cement; and
That MB -AE 90 meets the requirements of ASTM C 260, Corps of Engineers' CRD -C 13 and AASHTO M154, the
Standard Specifications for Air - Entraining Admixtures for Concrete.
Richard Hubbard
Sr. Technical Marketing Specialist, BASF Corporation
BASF Corporation
23700 Chagrin Boulvard Master
Cleveland, OH 44122
216 839 -7500 ph Builders
www.masterbuilders.com Admixture Solutions
The Chemical Company
January 2, 2013
TXI Operations, LP
1341 W. Mockingbird Lane
Dallas, Texas 75247
Attention: Victor Villarreal
Project: All Projects
Project location: Various Locations
Certificate of Conformance
Pozzolith® 100 XR
BASF Corporation* Admixture for Concrete
*(successor in interest to BASF Construction Chemicals, LLC , which is successor by merger to BASF Admixtures,
Inc., formerly known as Degussa Admixtures, Inc., formerly known as Master Builders, Inc.)
I, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,certify:
That Pozzolith 100 XR is a BASF Corporation Set Retarding Admixture for concrete; and
That no calcium chloride or chloride based ingredient is used in the manufacture of Pozzolith 100 XR; and
That Pozzolith 100 XR, based on the chlorides originating from all the ingredients used in its manufacture,
contributes less than 0.00014 percent (1.4 ppm) chloride ions by weight of the cement when used at the rate of 65
mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and
That Pozzolith 100 XR meets the requirements for a Type B, Retarding and Type D, Water- Reducing and Retarding
Admixture specified in ASTM C 494, Corps of Engineers' CRD -C 87 and AASHTO M194, the Standard
Specifications for Chemical Admixtures for Concrete.
Richard Hubbard
Sr. Technical Marketing Specialist, BASF Corporation
BASF Corporation
23700 Chagrin Boulvard Master
Cleveland, OH 44122
216 839 -7500 ph Builders
www.masterbuilders.com Admixture Solutions