CF-Andrew Park 2-LR 921015 (3)ATEC Associates, Inc.
11356 Mnthis Avenue
Dallas, Texas 75229
(214) 556-2204
METRO 263-1681
CONCRETE TEST REPORT
Project:
Client:
Andrew Brown Park
Tony Crawford Construction
Date Sampled:
Our Report No.:
10115/92
25-O2-92-0692g-20
Field Test Data
Location of Pour when Sampled: 100' N of Parkway St., Center of Driveway
Unit Weight: (C-138)
Sampled By: Scott Berry
Tune: Batched 07:51
Temperature: Air 74°F
Slump: 5.0 in.
(C-143)
Sampled 08:30
Concrete 78'F
Air Content 0 %
(C-173/C-2.31)
Supplier/Plant:
Delivery Ticket No.:
Truck Number: 227
Mix ID No.: 8,272
Water Added on site:
TXI, #31
4O166
Lond Size:
5 Gals.
10 cy.
Strength Test Results
I 11~, Lab 10-22 7 87.000 3,080
I 1199 Lab 11-12 28 114,500 4,050
I 1200 Lab 11-12 28 118,$00 4,190
Remarks:
Respectfully submitted,