Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ST9902-SP130702
$16 FERGusoN . Wa t ( 1 o r 'mss SUBMITTAL West Sandy Lake Phase 2A & 2B Coppell, Texas Four Star Excavating 6825 Levelland RD Ste. 2B Dallas, Texas 75252 0/4- ( Submitted By: Amanda Champion Email: amanda.champion @ferguson.com Ferguson Waterworks 2650 South Pipeline Rd (P) 817-267-3900 Euless,TX 76040 (F) 817-267-3912 www.ferguson.corn Contents: WATER: • PIPE o NORTH AMERICAN-C900 DR18 CL150 PVC PIPE o DIAMOND-C900 DRIB CL150 PVC PIPE • VALVES o MUELLER-GATE VALVES o SMITH BLAIR-TAPPING SLEEVE o TYLER UNION-VAVLE BOXES • FIRE HYDRANT o MUELLER-SUPER CENTURION HYDRANT • FITTINGS o TYLER UNION-C-153 FITTINGS o EBAA-SERIES 200 PVC RESTRAINT, SERIES 1100 DI RESTRAINT • SERVICE MATERIAL o MUELLER--COPPER TUBE o MUELLER CO.-SERVICE BRASS,TAPPING SADDLE, METER YOKE o WATTS-BACKFLOW PREVENTER o BASS & HAYS-METER BOX SEWER: • PIPE o NORTH AMERICAN PIPE-SDR35 PVC PIPE,SDR26 CL160 PIPE o DIAMOND-SDR35 PVC PIPE,SDR26 CL160 PIPE • CASTINGS o BASS& HAYS-400 Series RING & COVER • FITTINGS o MULTI FITTING-TRENCH TOUGH GASKETED o CHARLOTTE PIPE-CLEANOUT PLUG • CONCRETE STRUCTURES o TURNER-METER VAULT, MANHOLES o CRETEX-CHIMNY SEALS STORM DRAIN: • PIPE AND FITTINGS o CHARLOTTE PIPE—SCH40 PIPE o CANTEX—SCH40 CONDUIT PIPE • CASTINGS o BASS& HAYS—400 Series RING & COVER, CURB INLET WATER: • PIPE o NORTH AMERICAN-C900 DR18 CL150 PVC PIPE o DIAMOND-C900 DR18 CL150 PVC PIPE • VALVES o MUELLER-GATE VALVES o SMITH BLAIR-TAPPING SLEEVE o TYLER UNION-VAVLE BOXES • FIRE HYDRANT o MUELLER-SUPER CENTURION HYDRANT • FITTINGS o TYLER UNION-C-153 FITTINGS o EBAA-SERIES 200 PVC RESTRAINT,SERIES 1100 DI RESTRAINT • SERVICE MATERIAL o MUELLER--COPPER TUBE o MUELLER CO.-SERVICE BRASS, TAPPING SADDLE, METER YOKE o WATTS-BACKFLOW PREVENTER o BASS& HAYS-METER BOX North American Pipe Corporation www.northamericanpipe.com Product Description: AWWA C-900 rr - Municipal Water Pipe i North American Pipe's A\NWA C-900 PVC product G line is manufactured to meet the needs of modern ( t` ° municipal water distribution systems.With top quality raw materials and modern processing technology North American Pipe's C-900 pipe ri meets all industry standards in addition to our own rigorous quality control standards. North American Pipe's C-900 pipe utilizes Reiber style gaskets , throughout the entire product offering. North American Pipe produces a full range of CIOD pipe in DR-14, DR-18,and DR-25 classifications. Whether specifying or installing our pipe you can fr be assured that North American Pipe will provide the pipe"Right, On Time,All the Time". . This product is made in accordance with the following specifications: AWWA C900 ASTM D1784 ASTM D3139 ASTM F477 ANSI/NSF 14 ANSI/NSF 61 PPI TR-3 UL 1285 FM 1612 Short Form Specification for North American Pipe Corporation AWWA C-900 Municipal Water Pipe :‘‘ Water main distribution pipe shall be made in A W°`"` k,g* fg, accordance with AVWVA C900 from a compound conforming to a cell classification of 12454 as vrco, defined by ASTM D1784. Integral bells shall llni�}li incorporate gaskets meeting the requirements of lISiED ASTM F477 and be locked into the bell. The assembled joint shall meet the requirements of ASTM D3139. The laying length of the pipe shall be (i) ICO°' 20 feet. The pipe and gasket must be tested and approved for contact with potable water in 'PRO accordance with ANSI/NSF 61. The pipe and gasket shall be listed by Underwriters Laboratory and approved by Factory Mutual. Rev:08/2006 2801 Post Oak Blvd.I Suite 6001 Houston(TX I 77056 Phone: 713-840-7473 Toll Free 800-999-7473 Fax: 713-552-0087 North American . Pipe Corporation .__ . w www.northamericanpipe.com AWWA C-900 Municipal Water Pipe T — ........... ._-i ` t .� NOMINAL '- . OUTSIDE *APPROX:'"' ' "**APPROX.' 'INSERT - PIPE SIZE DIA.=`NOM BELL DIA. BELL DEPTH MIRK ", - (OD) '(BD) 4" 4.80 6.50 6.11 3.88 6" 6.90 9.25 7.34 5.13 8" 9.05 11.75 9.08 6.13 10" 11.10 14.25 9.75 6.63 12" 13.20 16.75 11.02 7.38 NOMINAL PC?100 PC 150 PC 200 PIPE SIZE DR 25 DR 18 DR 14 (T) Cr) (T) 4" .192 .267 .343 6" .276 .383 .493 8" .362 .503 .646 10" .444 .617 .793 12" .528 .733 .943 Note:These dimensions are for estimating purposes only •Dimension given for Approx.Bell Diameter(BD)is for highest pressure class ••Nominal depth,depth will vary by pressure class Rev:08/2006 2801 Post Oak Blvd.j Suite 600 j Houston(TX j 77056 Phone: 713-840-7473 Toll Free 800-999-7473 Fax 713-552-0087 . C900: PVC Pressure Pipe , `r SPECIFICATION DATA � k 1:- ,, Diamond (C900) PVC Pipe(4"through 12") � is made of 12454 compound per ASTM D1784,in accordance with the dimensional, chemical,and physical requirements of " AWWA C900. Diamond (C900) PVC Pipe bears the mark of NSF,International (NSF),the listing of � � a �:,1 .je �: Underwriters Laboratory,Inc.(UL),and ;�. (DR14&DR18) bears the listing of t ._ -mot ,' `, ! �� �- Factory Mutual(FM). 1� � =nom _ #: , =k. Diamond (C900) PVC Pipe utilizes a gasket, x per ASTM F477,to seal the integral bell socket "' qs to the spigot of the next joint(which conforms . � - - ' . to the requirements of ASTM D3139.) Each , .v male end is beveled to facilitate joint assembly, and the spigot is referenced marked to ensure proper insertion depth.Diamond furnished lubricant is to be used in the joining process. ` 'et , Factory Mutual Systems APPROVED Physical Properties of PVC 12454: Property P Y l �d ASTM Minimum Test , Specific Gravity D792 1.40 Tensile Strength,psi D638 7,000 Tensile Modulus,psi D638 400,000 IZOD Impact Strength D256 .65ft.,lb./in. Underwriter Laboratories Inc.© SHORT FORM Specification for Diamond C900 PVC Water Pipe Diamond C900 PVC Water Pipe shall be made of compounds conforming to ASTM Dl784 with a cell classifi20 cation foot of laying 12454.lengths.J Diamond oints C900 shall shall meet meet the all the dimensional,chemical,and physical requirements as outlined in AWWA C900 and will be supplied in requirements of ASTM D3139 and shall be formed using Rieber Technology.Gaskets shall meet the requirements of ASTM F477. Potable water pipe shall be manufactured from National Sanitation Foundation(NSF)approved compounds. 4\t\ DIAMOND , : PLASTICS° w „' ,, . A (.. r, \c,,,,,-„,..., ' Corporate Headquarters• 1212 Johnstown Road•P.O.Box 1608•Grand Island,NE 68802-1608 Page; w ,- t . t ; s `5 r �a - 4 —;''''''4''''' '`cc�zm, *r4 -:,4 , .:v,r w az.' Pa z��' a. ,1-,,,,-,'x�='-3;:.rm=. .1, ,. .; "'" 4 k �,..�i - , x �. , x _n $ Reiber Joint Illustration D .--,, C _ .. w; Extreme Testing C.or�z, on, ± ,'' r;: ._ r r C900 PVC pressure pipe,available in x : pressure ratings for a wide range of water ' transfer applications(Available in sizes " r� from 4"through 12") ii, , T - ---Awwil 1,1:iri. n. --rfr,--,-„,„,..,, ..,,, ..„ . ,.,,.......,, , ,, }k a3.?�; �' ' AWWA C900 SPECIFICATION DATA 'Tough + s: } ; , i4 age ;x' P € € i €,g{ , € " ;( g .V c9 '> 'r442 g ni g 3 ' n:' " ;" ',,'. i 4" (100) 4.800 (121.9) 6-1/2" 6 5 0.343 (8.71) 0.267 (6.78) 0.192 (4.88) 6"(150) 6.900 (175.3) 9-1/4" 6.5 6 0.493 (12.52) 0.383 (9.73) 0.276 (7.01) 8"(200) 9.050 (229.9) 11-3/4" 7 6.5 0.646 (16.41) 0.503 (12.78) 0.362 (9.19) 10"(250) 11.100 (281.9) 14-1/4" 7.5 7 0.793 (20.14) 0.617 (15.67) 0.444 (11.28) 12"(300) 13.200 (335.3) 16-3/4" 8 7.5 0.943 (23.95) 0.733 (18.62) 0.528 (13.41) _ ',possession of this page does not constitute an offer of sale"_ �� I DIAMOND a F' `T PLASTICS® :. Fs• A 1 , J rV Corporate Headquarters• 1212 Johnstown Road•P.O.Box 1608•Grand Island,NE 68802-1608 �..t,-. ,nom a' 3 4 -.:, e € s f,-, _ '' 5 8r '°a z 8 t:." ''> -x -s x 'r`. .2 'm.. ..fr,'94''',,;"` '� °�:_zz� ,_ r,..v:�9.u� .._ 10 . 16 'Mueller Co.) 2"-12" MUELLER®A-2360 RESILIENT Rev.8-04 Shaded area indicates change. WEDGE GATE VALVES M.J. x M.J. ID Catalog number– r A-2360-20 Mechanical joint ends(with mechanical joint unassembled accessories) A-2360-23 Mechanical joint ends(less mechanical joint accessories) A-2360-25 Mechanical joint ends(with transition gaskets) ''- ❑ Sizes-2",3",4",6",8",10",12" ;`' ❑ Meets or exceeds all applicable requirements of ANSI/AWWA C509 Standard and is 4 t certified to ANSI/NSF 61 P. s ' ID Standard mechanical joint ends comply with ANSI/AWWA C111 i� CI Iron body with nominal 10 mils MUELLER®Pro-GardTMFusion Epoxy Coated � interior and exterior surfaces ❑ Epoxy coating meets or exceeds all applicable requirements of ANSUAWWA C550 Standard and is certified to ANSI/NSF 61 ❑ Iron wedge,symmetrical&fully encapsulated with molded rubber;no exposed iron a' ❑ Non-rising stem(NRS) ❑ Triple 0-ring seal stuffing box(2 upper&1 lower 0-rings) ; Li 2"square wrench nut(optional handwheel available)—open left or open right s ` � ❑ 2"-12"sizes-250 psig(1723 kPa)maximum working pressure,500 psig(3447 kPa) `rt '� static test pressure A-2360-20 01 UL Listed,FM Approved:200 psig(1379 kPa)–3"-12"sizes M.J.accessories shipped unassembled amasnatanntingvnatam Options . ,_ � � . See pages 10.34 and 10.35 for more information on Resilient Wedge Gate Valve options ❑ Position indicators ❑ Stainless steel fasteners:Type 304,Type 316 ❑ ASTM B98-C66100/H02 stem ❑ Handwheel Resilient wedge gate valve parts Catalog Description Material Material standard –G-202 Part Mt ,G-200 No. �." G-zar 1G-16 Bonnet Bolts&Nuts Carbon Steel ASTM A307 Grade B,Zinc Plated G ������ G-at 6-201 G-41 Stuffing Box Bolts&Nuts Carbon Steel ASTM A307 Grade B,Zinc Plated &I 1 _7 G-208 G-49 Stem O-rings(3) Rubber ASTM D2000 ;� G-200 Wrench Nut Cap Screw Carbon Steel ASTM A307 Grade B,Zinc Plated iIlk:�_ '_�� � 0-203 G-201 Stuffing Box Seal Rubber ASTM D2000 ` ■\� G-210•' G-202 Wrench Nut Cast Iron ASTM A126 CL.B G-203 Stem Bronze ASTM B138 G-16 G-204 Hand Wheel(not shown) Cast Iron ASTM A126 CL.B \ \ c-219•• G-205 Stem Nut Bronze ASTM B62 M. c-ms G-206 Guide Cap Bearings Celcon % i G-207 Stuffing Box Cast iron ASTM A126 CL.B r 1 ✓ _ c-nz•• G-208 Anti-friction Washers(2) Celcon * ,� i G-209 Wedge, Cast Iron* ASTM A126 CL.B 7 t e l , G-209 Rubber Encapsulated //�i G-210** Bonnet Cast Iron ASTM A126 CL.B ^ c-zos G-211** Bonnet 0-ring Nitrile ASTM D2000 G-212** Body Cast Iron ASTM A126 CL.B *Fully encapsulated in molded rubber with no iron exposed — **Previous to 1999 these parts on 4"-12"valves were designed with a gasket instead of an 0-ring and _ with additional bolt holes(2"-3"sizes retain neoprene gasket design affecting these parts).Confirm ////////////////////////4 the type of seal when ordering a replacement gasket or 0-ring. _ SEE PAGE 10.39 FOR ORDERING INSTRUCTIONS 2"-12" MUELLER®A-2360 RESILIENT imuenef co.) WEDGE GATE VALVE - M.J. x M.J. 10 . 17 Rev.a AIL ■ O A ,_____i T- _ _ -\ I \ r 00 I .1_ , / \ DD---I L L 1 -H-FF -I Dimensions Dimension* Nominal size 2" 3• 4„ 6" A $n 10u 12" 9.88 12.38 14.19 18.00 21.50 25.50 28.62 FF 8.50 9.00 10.00 11.50 12.50 14.75 14.88 L 2.50 2.50 2.50 2.50 2.50 2.50 2.50 N 4.62 7.50 9.12 11.12 13.37 O(number and size of holes) 4-7/8 4-7/8 15.62 4-7/8 6-7/8 6-7/8 8-7/8 8 8-7/8-7/8 DD 3.50 4.00 Q(bore) 5.00 6.50 7.50 9.75 2.30 12.3 3.30 4.30 6.30 8.30 10.30 12.30 OO(bolt circle diameter) 5.00 6.19 7.50 9.50 11.75 Turns to open 8 11 14 14.00 38.5 20.5 26.5 33 38.5 Weight* 40 83 120 186 280 405 540 *All dimensions are in inches.All weights include accessories are in pounds and are approximate. t u .. 10, 14 'Mueller ca.) 4"-12" MUELLER®A-2360 RESILIENT WEDGE GATE VALVES M.J. x FL. Rev.8-04 Shaded area indicates change ❑ Catalog number— A-2360-16 mechanical joint x flanged ends(with mechanical joint unassembled accessories) A-2360-19 mechanical joint x flanged ends(less mechanical joint accessories) a.,lilt A ❑ Sizes—4",6",8",10",12" a W ❑ Meets or exceeds all applicable requirements of ANSUAWWA C509 Standard and is certified to ANSI/NSF 61 ❑ Flanged end dimensions and drilling comply with ANSI B16.1,class 125 ❑ Mechanical joint end complies with ANSI/AWWA C111 Standard - ❑ Iron body with nominal 10 mils MUELLER®ProGardTM Fusion Epoxy Coated interior and exterior surfaces ❑ Epoxy coating meets or exceeds all applicable requirements of ANSUAWWA C550 ,� ! Standard and is certified to ANSI/NSF 61 ❑ Iron wedge,symmetrical&fully encapsulated with molded rubber; � ' no exposed iron a ❑ Non-rising stem(NRS) 4 - ❑ Triple 0-ring seal stuffing box(2 upper&l lower 0-rings) ❑ 2"square wrench nut(optional handwheel available)—open left or open right ❑ 4"-12"sizes-250 psig(1723 kPa)maximum working pressure, A-2360-16 500 psig(3447 kPa)static test pressure M.J.accessories ❑ UL Listed,FM Approved—200 psig(1379 kPa) shipped unassembled Options See pages 10.34 and 10.35 for more information on Resilient Wedge Gate Valve options ❑ Position indicators ❑ Stainless steel fasteners:Type 304,Type 316 LI ASTM B98-C66100/H02 stem ❑ Handwheel or Resilient wedge gate valve parts Catalog Description Material Material standard —°-202 Part \R; G-200 No. �_,� G207 G-16 Bonnet Bolts&Nuts Carbon Steel ASTM A307 Grade B,Zinc Plated ✓ °-201 G-41 Stuffing Box Bolts&Nuts Carbon Steel ASTM A307 Grade B,Zinc Plated • 0-208 3 G-49 Stem 0-rings(3) Rubber ASTM D2000 /S G-200 Wrench Nut Cap Screw Carbon Steel ASTM A307 Grade B,Zinc Plated �` c-203 ��` J•\� G-201 Stuffing Box Seal Rubber ASTM D2000 °-2t°' G-202 Wrench Nut Cast Iron ASTM A126 CL.B G-16 G-203 Stem Bronze ASTM B138 G-204 Hand Wheel(not shown) Cast Iron ASTM A126 CL.B \ ��� G-205 Stem Nut Bronze ASTM B62 k— 0-205 G-206 Guide Cap Bearings Celcon i� %� / /G-212°° G-207 Stuffing Box Cast iron ASTM A126 CL.B rn G-208 Anti-friction Washers(2) Celcon �% ; i G 209 Wedge, CV�.A e / G204 Rubber Encapsulated Cast Iron* ASTM A126 CL.B ilipf G-210** Bonnet 0-206 Iron ASTM A126 CL.B G-21 1** Bonnet 0-ring Nitrite ASTM D2000 i G-212** Body Cast Iron ASTM A126 CL.B *Fully encapsulated in molded rubber with no iron exposed **Previous to 1999 these parts on 4"-12"valves were designed with a gasket instead of an 0-ring and with additional bolts.Confirm the type of seal when ordering a replacement gasket or 0-ring. //////l///"///////////// SEE PAGE 10.39 FOR ORDERING INSTRUCTIONS 4"-12" MUELLER®A-2360 RESILIENT Mueller Co.)10 . 15 WEDGE GATE VALVE - M.J. x FL. Rev.&04 "FIN- s. n B A OM* 1 1 .", N _ T N IUU i __T____ ..b., _ FE-- Dimensions Dimension* Nominal size 4" 6" 8" 10" 12" A 14.19 18.00 21.50 25.50 28.62 L 2.50 2.50 2.50 2.50 2.50 N 9.12 11.12 13.37 15.62 17.88 O(number and size of holes for MJ) 4--7/8" 6--7/8" 6--7/8" 8--7/8" 8-7/8" Q(bore) 4.30 6.30 8.30 10.30 12.30 00(bolt circle diameter for MJ) 7.50 9.50 11.75 14.00 16.25 R 9.00 11.00 13.50 16.00 19.00 UU(bolt circle diameter for FL) 7.50 9.50 11.75 14.25 17.00 FF 9.50 11.00 12.00 13.88 14.44 B(number and size of holes for FL) 8--3/4" 8--7/8" 8--7/8" 12--I" 12--I" Turns to open 14 20.5 26.5 33 38.5 Weight* 115 168 275 400 570 *All dimensions are in inches.All weights include accessories are in pounds and are approximate. 111..m. klmik 664 - Carbon Flange Tapping Sleeve 111111:15 Stainless Steel Flange Tapping 665 - g pping Sleeve \Wa'f" Stainless Steel Body and Neck Sated R ATV,CGSIPAhY ANSI/NSF®61 Listed Material Specifications c Body: Full circumference band. E... D 18-8 type 304 stainless steel. ---f Flanges: AWWA C207 Class D,ANSI 150#drilling. Recessed for Tapping Valve Per MSS-SP 60 MO — . Fusion bonded, Flexi-Coate epoxy coated carbon steel on 664. 18-8 type 304 stainless steel flange on 665. Optional:Other types of Flanges,threaded - iM1— __ _.1,_1� outlets, MJ Outlets — S = � —5/16 Gasket: Nitrile(Buna-N) NSFe 61 listed-compounded to libilidadhlhdial resist water, oil, acids, alkalies,most(aliphatic) hydrocarbon fluids and many chemicals. Temperatures-8 pe up t to 180°F.st F�--� Bolts,Nuts 18-8 type 304 stainless steel heavy hex nuts, A &Washers:stud bolts&washers. Nuts and studs are coated (E)Qty. of Bolts to prevent galling. (F)Size of Bolts Material specifications are subject to change. 664-665 Tapping Sleeve Specifications Outlet Size Nominal Body Size A(in) B(in) C(in) D(in) E(in). F(in) 4 15 5 5 1/16 4 3/16 8 5/8 4 6-18 15 5 5 1/16 4 3/4 8 5/8 20-24 20 5 5 1/16 4 3/4 8 5/8 6 15 5 7 1/16 6 5/16 8 5/8 6 8-18 15 5 7 1/16 6 3/4 8 5/8 20-24 20 5 7 1/16 ? 6 3/4 10 5/8 8 20 5 9 1/16 8 3/8 10 5/8 8 10-18 20 5 9 1/16 8 3/4 10 5/8 12-24 25 5 9 1/16 8 3/4 14 5/8 10 10 ; 25 5 11 3/32 10 1/4 14 5/8 12-24 25 5 11 3/32 10 3/4 14 5/8 12 12 25 5 13 3/32 12 1/4 14 5/8 14-24 25 5 13 3/32 12 3/4 14 5/8 Smith-Blair TS-620 9/06 13 4.....„.111, %.11: 664 - Carbon Flange Tapping Sleeve .. .. 665 - Stainless Steel Flange Tapping Sleeve Stainless Steel Body and Neck ''' h71111 Sofia-Fecie4.- A- .1. A SI?7•61.....CONCAkY ANSI/NSF®61 Listed 664 Nominal Size of 0.D. Flexi-Coate Stainless Approx. less Weight Pipe x Flanged Range Epoxy Coated _ Steel Flange Each Outlet (Inches) Carbon Steel Flange Pounds Catalog Number Catalog Number 4 x 4 4.50-4.80 664-04800400-200 665-04800400-200 34 4 x 4 4.80-5.10 664-05000400-200 665-05000400-200 42 6 x 6.69_6 99 664-06630400-000 665-06630400-000 55 6 x 6 ,.°' . ' ',... . 664-06630600-200 665-06630600-200 "'- 61 6 x 4 6 84 7 30 664-06900400-000 665-06900400-000 55 . 6 x 6 - . 664-06900600-200 665-06900600-200 61 6 x 4 - '– '':'-'''''. 664-07200400-000 ,,' ' 665-07200400-000 ""' - ' 55 6 6 , , ,, 7-,10-750 _ 7___ ' '., x - , , -,..,,. 664-072006007200-- L.' - 665-07200600-200 61 6 x 4 7 40 7 80 664-07450400-000 665-07450400-000 55 6 x 6 - .. 664-07450600-200 665-07450600-200 61 8 x 740_8.30 - 000 00-000 665-08000400-000 64 8 x 6 664-08000600-000 665-08000600-000 ,72 8 x 4 664-08630400-000 665-08630400-000 64 8 x 6 8.62-906 664-08630600-000 665-08630600-000 72 8 x 8 664-08630800-200 665-08630800-200 93 8 x 4 664-09050400-000 665-09050400-000 64 8 x 6 8.99-9.45 664-09050600-000 665-09050600-000 72 8 x 8 664-09050800-200 665-09050800-200 93 8 x 4 664-09450400-000 665-09450400-000 64 8 x 6 9.20-9.60 664-09450600-000 665-09450600-000 72 8 x 8 664-09450800-200 665-09450800-200 93 8 x 4 664-09650400-000 665-09650400-000 64 8 x 6 9.60-10.00 664-09650600-000 665-09650600-000 72 8 x 8 664-09650800-200 665-09650800-200 93 10 x 4 664-10000400-000 665-10000400-000 61 10 x 6 9.90-10.30 664-10000600-000 665-10000600-000 65 10 x 8 664-10000800-000 665-10000800-000 88 10 x 4 664-10750400-000 665 10750400 000 61 - - 10 x 6 664-10750600-000 665 10750600 000 10.73-11.13 _ _ _- , - , - 65 10 x 8 664-10750800-000 6o5-1075u800 000 88 - 10 x 10 664-10751000-200 665-10751000-200 95 10 x 4 664-11100400-000 665-11100400-000 61 10 x 6 11 05 11.45 664-11100600-000 665-11100600-000 65 . 10 x 8 - 664-11100800-000 665-11100800-000 88 10 x 10 664-11101000-200 665-11101000-200 95 10 x 4 664-11750400-000 665-11750400-000 61 10 x 6 1 1.70-12.10 - - - — 664-11750600-000 665 11750600 000 85 10 x 8 664-11750800-000 665-11750800-000 88 10 x 10 664-11751000-200 665-11751000-200 95 10 x 4 664-12000400-000 665-12000400-000 61 10 x 6 1 2.00-12.40 664-12000600-000 665-12000600-000 65 10 x 8 664-12000800-000 665-12000800-000 88 10 x 10 664-12001000-200 665-12001000-200 95 14 Smith-Blair TS-620 9/06 `lk 664 - Carbon Flange Tapping Sleeve � % %IWO665 - Stainless Steel Flange Tapping Sleeve ' ` � Stainless Steel Body and Neck `'° ^, / k S -S[atn ANSI/NSF®61 Listed �At.5L5 CW.1n .664 Nominal Size of O.D. Flexi-Coate 665 Approx. Pipe x Flanged Range Epoxy Coated, Stainless Weight Outlet (Inches) Carbon Steel,Flange Steel Flange Each Catalog Number Catalog Number Pounds 12 x 4 664-12750400-000 665-12750400-000 65 12 x 6 664-12750600-000 665-12750600-000 69 12 x 8 12.50-12.90 664-12750800-000 665-12750800-000 95 12 x 10 664-12751000-000 665-12751000-000 101 12 x 12 664-12751200-200 665-12751200-200 138 12 x 4 664713200400-000 , 665-13200400-000 65 12 x 6 .F 664-13200600 000 ., .. 665-13200600-000 69 !II'2 x 8 13 16 13 56 -664=12008-00.70O0 "665-1300800-000' 95• 12 x 10 664-13201000-000 -. 665;13201 boo 000 101 ..�, 12x12 , 864132012007200 W < .,665-13201200-200 138 12 x 4 664-13820400-000 665-13820400-000 63 12 x 6 664-13820600-000 665-13820600-000 67 12 x 8 13.60-14.09 664-13820800-000 665-13820800-000 90 12 x 10 664-13821000-000 665-13821000-000 113 12 x 12 664-13821200-200 665-13821200-200 128 12 x 4 664714250400-000 665-14250400-000 64 12 x 6 664-14250600-000 665-14250600-000 68 12 x 8 14.10-14.58 664-14250800-000 665-14250800-000 91 12 x 10 664-14251000-000 665-14251000-000 115 12 x 12 664-14251200-200 665.14251200-200 130 14 x 4 664-15300400-000 665-15300400-000 63 14 x 6 664-15300600-000 665-15300600-000 67 14 x 8 15.30-15.80 664-15300800-000 665-15300800-000 90 14 x 10 664-15301000-000 665-15301000-000 113 14 x 12 664-15301200-000 665-15301200-000 128 14 x 4 664=16000400-000 665-16000400-000 64 14 x 6 664-16000600-000 665-16000600-000 68 14 x 8 15.80-16.30 664-16000800-000 665-16000800-000 91 14 x 10 664-16001000-000 665-16001000-000 115 14 x'12 664-16001200-000 665-16001200-000 130 14 x 4 664-16400400-000 665-16400400-000 70 14 x 6 664-16400600-000 665-16400600-000 73 14 x 8 16.40-16.80 664-16400800-000 665-16400800-000 98 14 x 10 664-16401000-000 665-16401000-000 123 14 x 12 664-16401200-000 665-16401200-000 132 16 x 4 664-17400400-000 665-17400400-000 68 16 x 6 664-17400600-000 665-17400600-000 71 16 x 8 . 17.40-17.80 664-17400800-000 665-17400800-000 95 16 x 10 664-17401000-000 665-17401000-000 120 16 x 12 664-17401200-000 665-17401200-000 135 16-18 x 4 664-18700400-000 665-18700400-000 70 16-18 x 6 664-18700600-000 665-18700600-000 73 16-18 x 8 18.60-19.20 664-18700800-000 665-18700800-000 98 16-18 x 10 664-18701000-000 665-18701000-000 123 16-18 x 12 664-18701200-000 665-18701200-000 138 18-20 x 4 664-19500400-000 665-19500400-000 93 18-20 x 6 664-19500600-000 665-19500600-000 96 18-20 x 8 19.50-20.10 - 664-19500800-000 665-19500800-000 125 18-20 x 10 664-19501000-000 665-19501000-000 134 18-20 x 12 664-19501200-000 665-19501200-000 148 18-20 x 4 664-20900400-000 665-20900400-000 94 18-20 x 6 664-20900600-000 665-20900600-000 98 18-20 x 8 20.90-21.59 664-20900800-000 665-20900800-000 127 18-20 x 10 664-20901000-000 665-20901000-000 136 18-20 x 12 664-20901200-000 665-20901200-000 150 Smith-Blair TS-620 9/06 15 Salami 664 - Carbon Flange Tapping Sleeve .7 665 - Stainless Steel Flange Tapping Sleeve lain& t'itto4t- Stainless Steel Body and Neck w S -E . A SeAAA,C]NCAk9 ANSI/NSF®61 Listed 664 666 Approx. Nominal Size of 0.D. FlexI-Coat® Stainless Weight Pipe x Flanged Range Epoxy Coated; Steel Flange Each Outlet (Inches) Carbon Steel Flange Pounds Catalog Number Catalog Number 20 x 4 664-21600400-000 665-21600400-000 94 20 x 6 664-21600600-000 665-21600600-000 98 20 x 8 21.60-22.40 664-21600800-000 665-21600800-000 127 20 x 10 664-21601000-000 665-21601000-000 136 20 x 12 664-21601200-000 665-21601200-000 150 20-24 x 4'' 664-23500400-000 665-23500400-000 09 20=24 x 6:', 664-280'006'00-000 665-23500600-000 :102 20-24 x 8 23.50-24.20 ';664-23500800-000 665-23500800-000 r" 133 20-24 x 10 664 23501000-000 665-23501000-000 142 20-24 x 12 �, - 664-23501200-000 665-23501200-000 156 24 x 4 664-25800400-000 665-25800400-000 105 24 x 6 664-25800600-000 665-25800600-000 108 24 x 8 25.80-26.60 664-25800800-000 665-25800800-000 140 24 x 10 664-25801000-000 665-25801000-000 149 24 x 12 664-25801200-000 665-25801200-000 164 24 x 4 664-28300400-000 665-28300400-000 111 24 x 6 664-28300600-000 665-28300600-000 114 24 x 8 28.30-29.00 664-28300800-000 665-28300800-000 148 24 x 10 664-28301000-000 665-28301000-000 157 24 x 12 664-28301200-000 665-28301200-000 171 16 Smith-Blair TS-620 9/06 29U-Domestic Cast Iron Curb, Service & Valve Boxes TYLER UNION® Plus Components Quality Waterworks Products Revised 01/10 Adjustable Slip and Screw type with standard assembled lengths ranging from 15"to 72", not including risers and extensions. Note: See catalog or website for complete listing of components Produced in accordance with and meet all applicable terms and provisions of ASTM A-48 and are cast with 35B class cast iron. When properly installed will meet American Association of State Highway and Transportation Officials (AASHTO) H20 wheel load rating. INSTALLATION: Per AWWA M44,Manual of Water Supply Practices COA rl tki G. The bituminous coating is applied by the dipping method to a mil thickness of approxi- mately 1.0 to 1.5 mils. For 4"to 12"Valves For 3"to 20"Valves For 4"to 12"Valves For 4"to 12"Valves 51/4"Shaft,Screw Type 51/4"Shaft,Screw Type 51/4"Shaft,Slip Type 51/4"Shaft,Slip Type --5'4-1 5% r-53/4-1 9 h.5'411 i_ ., I ir=-704:-7111 1 1-75m—I II-5 4-11 r—9 1-77Z—, 1 6,43—■i ri _', T7 . 4,),J , 1 , . , 26. L ' > 4 ,.-,..-_, 5 1 5 5 E634--JI f 7'46 X It--....., 1 1 V2 .'AIM > :-...- I 1 St ,--ff 4 1 • 02 I.t 2...'"'.4 I IIV.5■41 irr L IL=661/,',1 61:2 91,2 61's 111 — '18 8 1 1 IL.—6%—II 6-7,4,—, Lei/8_1N -1.7_7----____I 1 lo 1/4 A lo 1/4 6850 SCREW TYPE 6860 SCREW TYPE 6855 SLIP TYPE 7126 SLIP TYPE VALVE BOX VALVE BOX VALVE BOX VALVE BOX Cast Iron-2 piece Cast Iron-3 piece Cast Iron-2 piece Extension Extension Extension Extension Components Height Components Height Components) Height Components Height 26T+24B 28-48 10T+ 15B 19-22 10T+ 12B 27-37 10T+ 15B 19-22 26T+30B 34-54 10T+24B 27-32 10T+ 18B 33-42 10T+24B 27-32 26T+ 36B 40-60 16T+24B 27-37 16T+24B 39-49 16T+ 24B 27-37 26T+24B+#60 Ext 52-72 16T+30B 33-43 16T+ 308 45-54 16T+ 30B 33-43 26T+36B+#60 Ext 60-80 16T+36B 39-50 16T+36B 51-60 161+ 36B 39-50 NOTE: Use the 6855 Bottoms 26T+30B 36-52 26T+ 308 45-66 26T+ 30B 36-52 with these Tops 26T+36B 39-60 26T+36B 51-72 26T+ 36B 39-60 26T+248+#60 Ext 51-71 NOTE:B R d 26T+ 24B+#60 Ext 51-71 ase equire , 26T+36B+#60 Ext 62-82 26T+ 36B+#60 Ext 62-82 Order Separately iii. _ is. 234 For 1/2"to 2"Curbstops l__ 1 r z1a 4 1 6500 SCREW TYPE T = Top CURB/SERVICE BOX Extension B = Bottom al <z Componets In Inches EXT = Extension 18T&27B 30-42 18T&3313 36-48 r, 24T&33B 36-54 1711_ --- * A L''''' 24T&39B 42-60 1223/41-- 30T&39B 41-64 L-toei 6%— *Enlarged Base Available Tyler Pipe Company • 11910 CR 492 • Tyler,Texas 75706 • (800)527-8478 Union Foundry Company • 1501 W. 17th Street •Anniston,Alabama 36202 • (800)226-7601 www tv6ri ininn rnm 9 . 8 Mueller Co. MUELLER® SUPER CENTURION® Rev.8-04 Shaded area indicates changes FIRE HYDRANT ...., :,: .., .a f.�—ran c M...= ,. .. ,- a", ��;'> r,"Xa ,w:�.--x' 'r�s�? 3r:`5.1 �. :.:;., ..€..;K;., .; =: ❑ Super Centurion 250'.3-way catalog numbers (approved to UL 246,FM 1510,ANSUAW WA C502 Standards)- ;t A-421 4-1/2"main valve opening three way(two hose nozzles and one pumper nozzle) A-423 5-1/4"main valve opening three way(two hose nozzles and one pumper nozzle) . i Super Centurion 200"'2-way catalog numbers (approved to ANS1/AW WA C502 Standards)- A-420 4-1/2"main valve opening two way(two hose nozzles) - ' A-422 5-1/4"main valve opening two way(two hose nozzles) 1 ', = A-425 5-1/4"main valve opening two way(two pumper nozzles) x1, Super Centurion 200"°1-way catalog number -t (approved to ANSUAW WA C502 Standards)- A r 4 A-424 4-1/2"main valve opening one way(one pumper nozzle) «:°" { ❑ 10 year limited warranty on material and workmanship ❑ Meets all applicable parts of ANSUAW WA C502 Standard Ti 1w l :. ❑ Post type dry barrel design ❑ Dry top design with 0-ring sealed oil reservoir ❑ Traffic feature with stainless steel safety stem coupling ❑ Compression-type main valve closes with pressure for positive seal;it is made of rubber and is conveniently reversible providing a spare for long service life ❑ Operating nut available in wide variety of shapes and sizes-open left or right ❑ Field replaceable hose and pumper nozzles ❑ Hose and pumper nozzles have large radius,full flow openings for low friction loss - ❑ Contoured shoe is designed for full flow ❑ Dual bronze drain valves provide effective barrel drainage ❑ 250 psig(1723 kPa)maximum working pressure,500 psig(3447 kPa)static test pressure for 3-way hydrants; 200 psig(1379 kPa)maximum working pressure,400 psig(2758 kPa)static test pressure for 2-way and 1-way hydrants . ;*r,^s,.¢ :f. s'G":re.,.aa„ s "= r '•3e ,' .a:tat3�+�m. ..��°w.,%;'� .,�;za,n;;s"' u. ,�»:�:..w+ ;'frei ,.,,._.. ;i-`?,w-,*�r '' i +'r Dimensions Mall _I .\s''...�\ Non-rotating +' \\\� bolt design: TIi cast-in pads elimi- nate ui a lmom i -- k\--[--, ��"•`� ,I for anti-rotation bolts. .� let Mechanical joint =1 _�II�I ` i�i� Jz standard and D-150 –ate;:i; //////� %„(c Front view detail �� y; of Mechanical joint O O �g f!.� ,o����\ (Standard only) j •� Flange '\N- r'�j��,, %\o\ ANSI 125/150 or ----1 �C��� II PN 10/16 Drilling s Bury•,'6'(0.16m) �wv�:--c3�no. \ �� 6'Shoe mfnimum;longerW 6' \ �� ( ) (152 mm)intery.. _Aw_. t���..,, `` Vertical 11 �� Flange* \\\\ \ rk ICI , � —(6'Shoe)'] ,������ �/ Slip-on i"° ms• ,~,",s i *4"Vertical shoe available for A-420 and A-421 hydrants. ,a4,.,- . a"-.- ,--: 'a i,,,.,s,3. per'. - ,--. ,.,_-k" " s"`"„ M.._..-.',: 5 Krti''.".'e§.`.',' ,,Y,-...'‘''3.:-,. t -" s ` ' ,...-'1,---.. --: '' SEE PAGE 9.28 FOR ORDERING INSTRUCTIONS 23U - Mechanical Joint C 153/A21 .53 TYLER UNIONr Compact Revised 01/10 Quality at rworks Products 2"through 48" (2"Not Referenced in C153/A21.53) ANSI/AWWA C153/A21.53-06 and NFPA 3"-12" UL Listed (EX2111) Note: Cast with tested and traceable ASTM A536 Ductile Iron PRESSURE M:7.I 2"-24" rated @ 350 PSI; 30"- 48"&all fittings with Flanged branches rated @ 250 PSI Note: With use of special flange gasket 2"-24"flanged fittings can be rated @ 350 psi For 350 psi flange joint applications,we recommend the use of annular ring type gasket or comparable. Note: Compact Wyes over 12"are not pressure rated. Contact manufacturer for rating in your application. Upon completion of installation,Mechanical Joint fittings 2"-12"are rated for a maxi- mum of 5°deflection and 14"-48" a maximum of 3°deflection Meets all requirements, UL Registered (2"-48") % _� ......_ M- B ANSI/AWWA C104/A21.4-08 L _ ANSI/AWWA Cl 04.A21.4-08, .31 Double cement lining available ■\\ NO: ANSI/AWWA C116/A21.16-09 lNote: Epoxy coated fittings are -available to the specification �� `�� required for your application(s) Available T' 7�, � ���' rT ANSI/AWWA C111/A21.11-7 Per AWWA C600-99 using pipe 0.75 conforming to ANSI/AWWA K2 J D C A 0.12 F K1 C151/A21.51-02 Size A Dia. B C Dia. D Dia. F Dia. 1 Dia. K' Dia. K2 Dia. L M S T X Size No. 3 3.96 2.50 4.84 4.94 4.06 6.19 7.62 7.69 .58 .62 .39 .33 3/4 %x3 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 .60 .75 .39 .34 '/a 3/4x31/2 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 .63 .88 .43 .36 '/s 3/4x31/2 6 8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 .66 1.00 .45 .38 7e 3/4x4 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 .70 1.00 .47 .40 % 3/4x4 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 .73 1.00 .49 .42 7/8 3/4x4 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 .79 1.25 .55 .47 7s 3/4x41/2 10 16 17.40 3.50 18.50 18.64 17.54 21.00 22.56 22.50 .85 1.31 .58 .50 7/8 3/4x41/2 12 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 .68 .54 7/s 3/4X41/2 12 20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 .69 .57 7s 3/4x41/2 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1.56 .75 .61 '/a %x5 16 30 32.00 4.00 33.29 33.46 32.17 36.88 39.12 39.12 1.31 2.00 .82 .66 11/8 1x6 20 36 38.30 4.00 39.59 39.76 38.47 43.75 46.00 46.00 1.45 2.00 1.00 .74 1 ya 1x6 24 42 44.50 4.00 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1.25 .82 1% 1'/4x6'/2 28 48 50.80 4.00 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 .90 1% 11/4x61/2 32 Tyler Pipe Company • 11910 CR 492 •Tyler,Texas 75706 • (800) 527-8478 Union Foundry Company • 1501 W. 17th Street • Anniston,Alabama 36202 • (800) 226-7601 A 101 - ,„ r‘ SERIES„ :ii:IR r‘ E S • • Mechanical Joint Restraint Your Connection to the FutureTM For PVC Pipe Features and Application: • Sizes 3 inch through 36 inch Sizes 42 inch and 48 inch ar -411%, Accommodated by Series 2200 ( - MEGA-BONDTm Restraint Coating System•• y ' a s•°e` •' -4 Y � tFo o r w mwwore e biinafao.rcmom at/iopn ro odn u cMts E/GmA e-BgOa-NbD on refer , . .$ fir . 3 • Constructed of ASTM, ,t� ,::,,,r; '::,-.1.7z;:s5' t!--`-'4-''' -'..--.' t'''' .44-0,,,:-..A.:%v*V-i44:44.0r- "44-:AufA, --4.-'',2- 65-45-12 Ductile Iron. , ,,,,s,l, , - . - "1".4 dAiff' ''' ' ''' ' .Fsvf,"■,* a 1...,,, t.1 • The Mechanical Joint follower gland is incorporated into the ` . •. -; restraint. Apr : r `x `r • Y .. . Heavy Duty thick wall design 4 • Su Products v •pport Split MJ repair style A available for 3 inch through 12 inch. EBAA Series 2000SV Series 2012PV, for 12"Mechanical Joint Pipe or Fittings • Solid restraint harness available for C905 PVC pipe bells. EBAA Series 2800 • Split restraint harness available for C900 and C905 pipe bells and Nominal Series Shipping . PVC fittings. PileSlie Number Wet:hts EBAA Series 1500,1600 and 2500 3 2003 7.0 4 2004 8.8 • All 2000PV and related restraint 6 2006 12.1 products can be furnished as 8 2008 1E3' 10 2010 26.0 paagd ace ct 12 2012 31,4 with ck appropriate e cessori restraints o,mgasketplee , 14 2014 47.6 lubrication and bolting hardware. 16 2016 52.8 18 2018 61.8 For use on water or wastewater 20 2020 70.9 24 2024 929 pipelines subject to hydrostatic 30 2030 128.5 pressure and tested in accordance 36 2036 161.3 with either AWWA C6OO or mote ForapphcaOons0,press l,resother than theones shown' ASTM D2774. please contact EBAA for asststance. U.S. Patent No. 4627774, 4896903, 5071175. -,rr r.?•x3— tw,-0-,r• Ar-,➢ -sr:<.:-S ...ro.'. ,,!'c . _,/0111777-1777-",:f-Y".''•-'a �ww," - t" -" ' --�.� ^70• � c W I,kQ yr t t 1 • Series 2000PV: Mechanical Joint Restraint Gland for use with C900 or IPS OD PVC Pipe The 2000PV mechanical joint restraint is the fastest and Tested to and meets the requirements of ASTM F 1674-96 most economical method of restraining PVC pipe to mechanical "Standard"Test Method for Joint Restraint Products for Use with joints.Now the need for costly concrete thrust blocks and PVC Pipe"through 24 inch size. corrodible steel tie rods is eliminated. It can be used in straight UL listed in the four through twelve inch sizes for joining UL alignment or at the preset deflection recommended for the listed ductile iron fittings to UL-listed,Class 150 PVC pressure mechanical joint. pipe.The maximum allowable joint deflection is five degrees. The 2000PV was the first PVC joint restraint to be tested to Factory Mutual approved for use on DR18 PVC pipe in four UNI-B-13,Underwriters Laboratories,and Factory Mutual, through twelve inch sizes. 1Z: SIK,y,l of Er<r/y�r' U L ASTM lln Be)!} F1674 `��� APPROVED AwwA B(1 PRE AS°C '.\ot M E M B E R The 2000PV Concept EBAA Iron started manufacturing joint restraint products for PVC pipe in The design of the 2000PV incorporates the early 1980s.The testing of early prototypes of various configurations of the gripping mechanism into the design of restraints on large diameter PVC pipe indicated that a restraint device must the mechanical joint gland and utilizes a be capable of consistently and reliably gripping the pipe.If not,the restraint simple two part assembly process.The first can slip under pressure,resulting in sudden impact,and cause the pipe to step involves assembling the joint the same burst.Armed with this background knowledge and an appreciation for the as any standard mechanical joint.The capabilities of PVC pipe,EBAA purposefully deviated from what many in the assembly procedure we recommend is that industry once considered to be the"only"way to grip PVC pipe.This led to established in AWWA C600.The second is the development of the Series 2000PV restraint. the actuation of the restraint. Three Testing Methods The design philosophy 1'°' One of the behind the 2000PV joint primary tests of restraint is that the pipe .;'' PVC is its quick , with the restraint should be burst strength. For �w.- capable of being tested to eE pipe meeting the n, , the same minimum , requirements of AWWA " requirements of the pipe C900, AWWA C905, and ° . alone. In doing so, the ASTM 2241, the minimum restraint is shown to have fir. quick burst requirement no detrimental effect on the for the hoop stress is 6400 S11.4. � , . pipe and will have the same ' psi. For DR18 pipe that pressure rating and safety pressure is 755 psi. "� factor as the pipe on which 0,-. The second test is � ' it is used To that end sustained pressure test at a hoop 2000PV has been subjected stress of 4200 psi. For DR18 pipe to hundreds of static and that pressure is 500 psi. cyclic pressure tests to Third, a conservative cyclic demonstrate the pressure surge design for the performance and reliability pipe exists in the form of of the restraint. 6 �,� _ =: Vinson Equation. ri The 2000PV restraint � ?� `� has been tested to over one i ''''''''''''' 1‘ ''',1'..' ri. ''' '''' ''''I';'11'1"---,' '°-.ft million cycles to the peak -''''','1 4.-'.",;1-'0,,',‘..44-1v:'7,-1472-r4:". '''‘`r'.1/4:t4%715,4#1:44;i*:'_.,e,. : Jil- ,.,,,,,,, .-, ,,- .0,,-I.,.. x.. li-,'i1).--1,''''!"".':':' pressures predicted by the Vinson Equation for } -r ` that number of cycles. Series 2000PV Takes the Load On April 11, 1997 EBAA Iron performed a remarkable force demonstration of their Series 2000PV joint restraint. With the use of EBAA's Series 2000PV using a standard mechanical joint installation on 12 inch PVC Pipe, and a 80 Ton motor crane, EBAA Iron lifted a D7 Caterpillar Track Type Tractor weighing in at 50,350 lbs. Along with this, the Series 2000PV has been tested to over 700 PSI. Concluding that EBAA's Series 2000PV can take the load. Mechanical Joint Restraint Sample Specification (The text of the specifications below can be copied and pasted from www.ebaa.com/download/2000spec.doc) Restraint devices for mechanical joint fittings and appurtenances conforming to either ANSI/AWWA C111/A21.11 or ANSI/AWWA C153/A21.53,shall conform to the following: Design Approvals Restraint devices for nominal pipe All physical and chemical test results Mechanical Joint Restraints shall be sizes 3 inch through 36 inch shall shall be recorded such that they can Listed by Underwriters Laboratories in consist of multiple gripping wedges be accessed via the identification the 4 inch through 12 inch sizes. incorporated into a follower gland number on the casting. These Mechanical Joint Restraints shall be meeting the applicable requirements Material Traceability Records(MTR's) Factory Mutual Approved in the 4 inch of ANSI/AWWA C111/A21.11. are to be made available,in hard copy, through 12 inch sizes. The devices shall have a working to the purchaser that requests such documentation and submits his gland Mechanical Joint Restraints,4 inch pressure rating equal to that of the through 24 inch,shall meet or exceed pipe on which it is used. Ratings are body identification number. g the requirements of ASTM F1674 of for water pressure and must include a Production pieces that are too small to the latest revision. minimum safety factor of 2:1 in all accommodate individual numbering, sizes. such as fasteners and wedges,shall Mechanical joint restraint shall be be controlled in segregate inventory Series 2000PV produced by EBAA Iron Material until such time as all quality control Inc.or approved equal. Gland body,wedges and wedge tests are passed. These component MEGA-BONDTM Restraint Coating System actuating components shall be cast parts may then be released to a from grade 65-45-12 ductile iron general inventory for final assembly All wedge assemblies and related parts material in accordance with ASTM and packaging. All components shall shall be processed through a phosphate A536. be manufactured and assembled in wash,rinse and drying operation prior to the United States. The purchaser coating application.The coating shall Three(3)test bars shall be consist of a minimum of two coats of incrementally poured per production shall,with reasonable notice,have the liquid Xylan®fluoropolymer coating with per Underwriter's Laboratory right to plant visitation at his/her shift as p y expense. heat cure to follow each coat. (U.L.)specifications and ASTM A536. All casting bodies shall be surface Testing for tensile,yield and elongation Installation pretreated with a phosphate wash,rinse shall be done in accordance with Mechanical joint restraint shall require and sealer before drying.The coating ASTM E8. Chemical and nodularity conventional tools and installation shall be electrostatically applied and tests shall be performed as procedures per AWWA C600,while heat cured.The coating shall be a recommended by the Ductile Iron retaining full mechanical joint polyester based powder to provide Society,on a per ladle basis. deflection during assembly as well as corrosion,impact and UV resistance. Traceability allowing joint deflection after assembl . An identification number consisting The coating system shall be MEGA g of y BOND by EBAA Iron,Inc.or approved year,day,plant and shift Proper actuation of the gripping equal. Requests for approved equal (YYDDD)(plant designation)(Shift wedges shall be ensured with torque must submit coating material and number),shall be cast into each gland limiting twist off nuts. process details for review prior to bid. body. For more information regarding MEGA-BOND,refer to the MEGA-BOND brochure or visit www.ebaa.com. Support Products for more information concerning these products please consult the catalog or www.ebaa.com ,- 6 - > Series 2200 Series 2500 .-t ,., , MEGALUG Restraint for Restraint for C900 and C905 4 _f C905 PVC Pipe at PVC pipe at PVC fittings_ I Mechanical Joint Fittings g (Now Available in Sues ��. : ' ` (Size'42 and 48 inches) 42 and 48 inch) r trom Series 2800 r r = Bell Restraint Harness !, for C905 PVC Pipe Series 2000SV' I �4.7 'i (Now Available in Sizes Split 2000PV Restraint `. ' -. "`1„, ! 42 and 48 inch) fnr (-vie ind.Morhnnirol Ing.,+c '"�_ Series 2000PV Submittal Reference Drawing A 1111 mok M o nn E ♦%`� A I J \„9 1 92i SPACER Ill a ri A lt X x0.75 C K2 J F C �'��%// P n �R �\,4 B 1/ 0.125-- I 0.125-I C u N �/ I I A B 1111 SECTION A-A SECTION B-B C D F MP P X J K2 Wedge Bolt Weight Nominal Series (with Qty Qty LBS Pi'a Size Number nuts Off 3 2003 4.84 1.55 3.60 0.50 9,8 8.6 3/4 6.19 7.69 4 4 7.0 4 2004 5.92 1.68 4.90 0.50 10.5 9.5 7/8 7.50 9.13 4 4 8.8 6 2006 8.02 1.68 7.00 0.50 13.0 12.1 7/8 9.50 11.13 6 6 12.1 8 2008 10.17 1,68 9,15 0,62 14.5 13.6 7/8 11.75 13.38 6 6 16.3 10 2010 12.22 2,10 11.20 0.62 17.0 16.0 7/8 14,00 15.63 8 8 26.0 12 2012 14.32 2.10 13,30 0.75 19.0 181 7/8 16.25 17.88 8 8 31.4 14 2014 16.40 2.25 15.49 0.88 217 20.9 7/8 18.75 20.38 10 10 47,6 16 2016 18.50 2.25 17.58 0.88 23.8 23.0 7/8 21.00 22.63 12 12 52.8 18 2018 20.60 2.25 19.68 . 1.13 25.9. 25.1 7/8 23.25 24.88 12 12 61.8 20 2020 22.70 2.25 21.79 1.25 28.0 27.2 7/8 25.50 27.13 14 14 70.9 24 . 2024 26.90 2.75 25.99 1.42 32.3 31.5 7/8 30.00 31.63 16 16 92.9 30 2030 33.29 2.70 32.22 1.50 38.5 37,7 11/8 36.88 39.12 20 20 128.5 36 2036 39.59 2.70 38.52 1,50 44.8 44.0 11/8 43.75 46.00 24 24 161.3 Pressure Ratings Note Dimensions are in inches and are subject to change without notice, Nominal Ratings for Ordinary Ratings for Peak Pressures used in Sewage Force Mains Series Water w/Transient Surges Only and Other Installations Designed for Cyclic Surges of 1•Mill.Cycles C905 PVC Pipe Pipe Size Number DR•14 DR-18 DR•25 SDR-17 SDR•21 SDR•26 DR•14 DR-18 DR•25 SDR•17 SDR•21 SDR•26 DR•18 DR-25 DR•32.5 3 2003 200 150 100 250 200 160 200 150 100 200 160 120 • 4 2004 200 150 100 250 200 160 200 150 100 200 160 120 • 6 2006 200 150 100 250 200 160 200 150 100 200 160 120 • 8 2008 200 150 100 250 200 160 200 150 100 200 160 120 • 10 2010 200 150 100 250 200 160 200 150 100 200 160 120 • - 12 2012 200 150 100 250 200 160 200 150 100 200 160 120 • 14 2014 235 165 • 16 2016 235 165 • 18 2018 235 165 • 20 2020 235 165 • 24 2024 • • 235 165 - 30 2030 165 36 2036 125 • Spacer Instructions C900 PVC Pipe ASTM 2241. PVC Pipe (IPS ('It''' For installation on trp„, . .* For installation on ASTM 2241 - C900 PVC pipe,use Leave sized pipe,remove -- Remove as received and —Spacer spacers and replace .. Spacer install per screws.Install per instructions. instructions. Installation Instructions 2 3. "-Yf a r �sry � ` '.w , ” �Y '' '" ue ws 1 s a $ �➢k �-T d a #& ua # 1. Identify the pipe.The 2000PV is for use *2.Clean the socket and the plain end. *3.Insert the pipe into the socket and press with PVC pipe.The 4"through 12"size may Lubrication and additional cleaning should the gasket firmly and evenly into the be used on both C900 and IPS PVC pipe. be provided by brushing both the gasket gasket recess. Keep the joint straight Check to see if the spacers under the and the plain end with soapy water or during assembly. screws are in place. If the pipe is C900, approved pipe lubrication meeting the proceed with spacers in place.If the pipe requirements of ANSI/AWWA *4•Push the gland toward the socket and is IPS OD,remove the spacers.Since the C111/A21.11,just prior to slipping the center it around the pipe with the gland lip 3"and the 14"through 24"restraints are gasket onto the plain end for joint against the gasket.Insert bolts and hand only used with one pipe diameter, no assembly.Place the gland on the plain end tighten nuts. Make deflection after joint spacers are used. with the lip extension toward the plain end, assembly but before tightening bolts. followed by the gasket. 4(cant 5. -RI 6. r h ': } - P ° � al , *5.Tighten the bolts to the normal range of remaining bolts. Repeat the process until 7. If removal is necessary,utilize the 5/8"hex bolt torque(45-60 ft-lbs for 3",75-90 ft-lbs all bolts are within the appropriate range of heads provided.If reassembly is required, for 4"through 24", 100-120 ft-lbs for 30" torque.The use of a torque indicating assemble the joint in the same manner as and 36",and 120-150 ft-lbs for 42"and wrench will facilitate this procedure. above,tighten the screws to 60 to 80 ft- 48")while at all times maintaining lbs.If the Series 2000PV restraint is approximately the same distances 6.Tighten the torque limiting twist off nuts in removed from the pipe,be sure that all of between the gland and the face of the a clockwise direction(direction indicated the screws,spacers(if required),and flange at all points around the socket.This by arrow on top of nut) until all wedges are wedges are in place before the restraint is can be accomplished by partially tightening in firm contact with the pipe surface. reassembled. the bottom bolt first,then the top bolt,next Continue tightening in an alternating the bolts at either side,finally the manner until all of the nuts have been These steps are requirements of AWWA. twisted off. AWWA Standards,C600,Sec.3.4.2 Members of... EBAA IRON Sales, Inc. ******-**** ii 'l J% P.O.Box 857,Eastland,TX 76448 ********** ` i J� * > * * * tea /� t ��,,-,L. Tel:(254)629.1731 Fax:(254)629.8931 * * * * * * . fi �� (800)433.1716 within US and Canada eontaet@ebaa.eom ._....... A MEGAWG® EB IR N s4` 0 Series 1100 Your Connection to the FutureTM Mechanical Joint Restraint for Ductile Iron Pipe �� Features and Applications: 6* , �" • Sizes 3 inch through 48 inch x "1 ¢ • Constructed of ASTM A536 Ductile Iron _ ' r • Torque Limiting Twist-Off Nuts -� • MEGA-BOND® spa Restraint Coating System vt For more information on MEGA-BOND, . refer to www.ebaa.com #� �•� � �� i � �.�'���•� � • The Mechanical Joint Follower Gland is I' , . incorporated into the restraint g, 1 1 .....', • Heavy Duty thick wall design Post Pressure • Support Products Available: Nominal Series Shipping Assembly Rating Split repair style available 3 inch Pipe Size Number Weights Deflection (PSI) through 48 inch. 3 1103 6.1 3° 350 EBAA Series 1100SD 4 1104 7.7 3° 350 6 1106 11.9 3. 350 Solid restraint harness available for 8 1108 14.8 3° 350 push-on pipe bells. 10 1110 23.9 3° 350 EBAA Series 1700 12 1112 31.2 3° 350 Split restraint harness available for 14 1114 48.5 2° 350 existing push-on bells. 16 1116 56.4 2° 350 EBAA Series 1100HD 18 1118 63.1 11 0 250 20 1120 72.3 11/2° 250 • All MEGALUG and related restraint 24 1124 133.1 11/20 250 products can be furnished as packaged 30 1130 194.6 1° 250 accessories complete with appropriate 36 1136 234.0 1° 250 restraint, gasket, lubrication, and bolt- 42 1142 536.0 1° 250 ing hardware 48 1148 653.0 1° 250 • For use on water or wastewater pipe- NOTE:For applications or pressures other than those shown please lines subject to hydrostatic pressure contact EBAA for assistance. and tested in accordance with either AWWA C600 or ASTM D2774 Made In U.S. Patent Nos. 4092036, 4627774, 4779900, 4896903, 5544922 rte_ I Inn yr s x4 ta .,, : :�a ' 4 a <7,. ,, s �. _4 �. _ r . 44;.--w� .�,, , s n�.-r ` > a { 1, b . - J i V� � l .� 13� � r �� � .=� k =fi �� a ` t' fi'� i s ' f i r ,t ,l,"'- ' ' t i ' +' ) i"b s: . ` L � '` r 1: S g pi r; � t * /r.. i 2{ d a ' `i " dr ' ' vr�t" � # Gg ,P:,..' "iii 151:,'O' mh' ; ' x .,,,k44,,,,&,95' ' nti..i4 + '' s j ...?":4,$!..t.,' 4,.$4. 7-114%1'Al 4A,44,:jir,. 24,./Prt-17:,-'' ',:( t°..'''-/4.,'..,, . 4,'. V. 'fil;i0„, , - 14,, P,i,, ..i,1 ir. ik - tpti#‘ ,.. ,7.:44:4„,..,44,_ ,,z.; _.1.,..z.k .2,....,,t, .,, „I:7, - ^-,...„, f. 3..A.K,4*,. ..4 t. .,, ,,,..„,.„, ,..4:,, ,44,,,,,_ c p` 4, kaw `get f a rs .: w� a y s is --,,:. --. %;+„v--a mss ° ,--,- '� .- '-`� F " ' '-'�� �...o �aa�ffi :,..*,7-."01"-. h:2 a 1 �.,- ....+�- :rte_- _ ..� _ �,ar �� ..d"'�.,.-. ��3£ MEGALUG:THE PRODUCT OF PREFERENCE SINCE 1984 Since 1984,engineers and contractors designing and installing Major testing laboratories agree as the 3"through 24"sizes water and wastewater pipelines and systems have come to rely are Underwriters Laboratories(UL)listed,and the 3"through 12" on the EBAA Series 1100 MEGALUG Mechanical Joint Restraint sizes are Factory Mutual(FM)approved. as the"Product of Preference"for effectively and economically For use on all classes of ductile iron pipe(PC350 through restraining ductile iron pipe connections above or below ground. PC150 and CL56 through CL50),for practically any application MEGALUG Mechanical Joint Restraints replace external re including valves,hydrants and pipe,the MEGALUG Mechanical straints such as cumbersome concrete thrust blocks and corrod- Joint Restraint effectively and safely performs without damage to ible metal tie rods creating a quicker,safer and more economical the pipe or cement linings. installation. THE MEGALUG GRIPPING WEDGE... PERFORMANCE PROVEN The wedge style MEGALUG design reacts cyclic loads.This has been tested to very to the amount of force acting on the joint. Mexpfonoore high-pressure differentials and the wedge When each wedge is set,the wedge teeth o Mo ement impressions look the same as if a single test had been performed. penetrate the pipe's outer surface,and wedea,u a — Max mo emee the wedge does not move on the pipe. - 9r,Paa ee Typically,the depth of pipe wall pen- There is very little change in this interface __Rntedpreasure etration,or wedge impression at around until the wedge movement begins inside w Wedgemo smear 25,000 pounds of force per wedge(200 the pocket of the main casting.Once the o begins PSI on a six inch and 150 PSI on a twelve wedge starts moving,the formation of the ;e�ure°stating inch)is 0.03". Finally,at roughly twice that buttress begins. ai force the penetration is around 0.05"At This"dam"of material(the wedge a these high pressures,there is no affect on impression) is cold formed as the wedging MOVEMENT the design thickness of ductile iron pipe action continues. If the force of pressure made according to AWWA C150.The lack acting on the joint is released,the wedge of the pocket at the maximum pressure or of damage to the cement lining clearly moves back to near its original position. load,the wedge buttress are in shear.The indicates that the thrust load is primarily This engages the reserve controlled move- movement t is about 0.3 inch longitudinal. ment or"RCM".The wedge is then ready through the thirty-six inch size and 0.4 This ability to move in the pocket allows for another round. inch for forty-two and forty-eight inch. for angular flexibility as well as longitudi- After the wedge has moved to the back The RCM is available even with severe nal flexibility. 8A.34 Mueller Co. COPPER METER YOKES WITH HORIZONTAL INLET Rev.8-04 & OUTLET (FOR 1-112° & 21` FLANGED METERS) AND BYPASS 0 I, t 1 ?'' With lock wing 1 ' m �' +,' B� ground key angle -., r�' + With lock wing -2 meter valve with q '21`: ground key angle meter flange x anglo '' !*"" "� 1� " -C meter valve with f i I 0 dual chock valve with meter Ranee x Lock I With lock wing round key p meter flange.Check t angle meter valve with meter rrt wing ground key angle r, valve in front of j °': c meter valve with meter bypass valve. ; flange x lock wing ground key flange. t. angle meter valve with meter .( 1 flange. ,1 J t. � " , i '1 f - i. . ,. M Y-. i -, : F i' o .t a; y P - • t t;1 ' ,i -- ,i H-1423 H-1423-2 H-1423-2-99000 FIP end inlets FIP end inlets FIP end inlets shown with and outlets and outlets and outlets check valve in optional 1-1/2" and 2" Copper meter setters (with by-pass) location Catalog number H-1423 H-1423-2/H-1423-2-01" H-1423-99000/-1423-2-99000 Description With lock wing ground key With lock wing ground key With lock wing ground key angle meter valve with meter angle meter valve with meter angle meter valve with meter flange x lock wing ground flange x angle dual check flange x lock wing ground key key angle meter valve with valve with meter flange. valve with meter flange. meter flange. By-pass with By-pass with lock wing Elevated by-pass with lock wing Mueller'Bali Mueller"Ball Valve and check Mueller$Ball Valve with Valve valve(without bypass"check locking device(with check valve:H-1423-2-01). valve:H-1423-2-99000). 'For ASSE Approved canister dual check-add 6A for regular or 6D for drain T 14 I P --BP re_ MI .t., 'i _S i� Sho n2 Ili �iIiI '1ssts asiij] B Ill II to. EN B H-1423-2-99000 II 1 i _ I I Shown ,� II E —aline /1111.Ii,�a11:1 it ,,�� ., C �- O� D O� - Io�1 OM. b [11111 . 11 Dimensions C 1 D Meter size 1-1I2"H-1423, 2"H-1423 H-1423-2& 1-1/2"H-1423-99000 2"H-1423-99000& H-1423-2&H-1423-2-01 H-1423-2-bi &H-1423-2-99000 H-1423-2-99000 Dimension A* 13.25' 17.25' 13.25' 1725' Dimension B-riser height 12',15°,18',21',24%27' 12',15',18",21',24°,27' 18',21',24°,27' 18',21",24',27° Dimension C-nominal pipe 1-1/2° 2' 1-If2" 2' size of inlet and outlet Dimension D'* 2150' 26.63" 2150° 26.63° DimensionE - - 7.25° 7.25' •Adjustable dimension. Copper tubing in the tie bar can be cut to accomodate shorter meters.Adjustment affects both A and D dimensions. See section 6 for end connections that can he used with these yokes. SPECIFY METER SIZE,RISER HEIGHT AND CATALOG NUMBER ES-007 For Non-Health Hazard Applications Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Series 007 Double Check Valve Assemblies Sizes: 1/2" -3" (15-80mm) Series 007 Double Check Valve Assemblies shall be installed at ` , referenced cross-connections to prevent the backflow of pollut- e ed water into the potable water supply.Only those cross-con- F' 1 nections identified by local inspection authorities as non-health hazard shall be allowed the use of an approved double check ,/, (20mm)007M3gT valve assembly. Check with local authority having jurisdiction regarding vertical orientation,frequency of testing or other installation requirements. The valve shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510.Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University offi, Southern California. Imam lsurnt't+ t -7,-*101,t Features 2"(50mm)007M1QT HC • Ease of maintenance — only one cover • Top entry Test Cocks • Replaceable seats and seat discs --- • Modular construction _v_ • Compact design ewo O m MI • Cast bronze body construction — 1/2"—2" (15—50mm) ■I7 0.02>V74 • Fused epoxy coated cast iron body— 21/2"—3" (65—80mm) —qa� � ,r���,�,q��a • Top mounted ball valve test cocks � • Low pressure drop 11i �-■T_.■' - —- • No special tools required for servicing f 1 affix """® nsVen 0000no osostaa u • 1/2"—1"(15—25mm)have tee handles `•, First Check Second Check Specifications Module Assembly Module Assembly A Double Check Valve Assembly shall be installed at each The 007 Series features a modular design concept which facilitates noted location.The assembly shall consist of two positive seat- complete maintenance and assembly by retaining the spring load. ing check modules with captured springs and rubber seat discs.The check module seats and seat discs shall be Now Available replaceable. Service of all internal components shall be through WattsBox Insulated Enclosures. a single access cover secured with stainless steel bolts.The For more information,send for literature ES-WB. assembly shall also include two resilient seated isolation valves; four top mounted, resilient seated test cocks.The assembly shall meet the requirements of ASSE Std. 1015 and AWWA IMPORTANT:INQUIRE WITH GOVERNING AUTHORITIES Std. C510.Approved by the Foundation for Cross-Connection FOR LOCAL INSTALL411ON REQUIREMENTS Control and Hydraulic Research at the University of Southern California.Assembly shall be a Watts Series 007. Watts product contact spatscechni in U.S.Service.Watts units and metric are change or modify and are provided product d design,for reference only.For precise,measurements,mrials i ® please coniad Warts Technical Service.Watts reserves the right to change or modify product design,consWction,specifications,or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Pressure — Temperature Suffix: 1/2"–2" (15–50mm) S-bronze strainer Temperature Range:33°F–180°F(0.5°C–82°C). LF-without shutoff valves Maximum Working Pressure: 175psi(12.1 bar). LH-locking handle ball valves(open position) 21/2"–3" (65–80mm) SH -stainless steel ball valve handles Temperature Range:33°F–110°F(0.5°C–43°C)continuous, HC-212" inlet/outlet fire hydrant fittings(2"valve) 140°F(60°C)intermittent. Prefix: Maximum Working Pressure: 175psi(12.1 bar). U-Union connections 21/2"–3" (65–80mm) Standards Suffix: ASSE Std. 1015,AWWA Std. C510 NRS-non-rising stem resilient seated gate valves IAPMO PS31,CSA B64.5 OSY- UL/FM outside stem and yoke resilient seated gate � o valves Approvals B$E j® �L LF-without shutoff valves t ASSE,AWWA, IAPMO,CSA, UPC QT-FDA-FDA epoxy coated quarter-turn ball valves • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. • Models LF and S are not listed. • UL Classified (LF models only)3/4"–2" (20–50mm) (except 007M3LF) • UL Classified with OSY gate valves (21/2"and 3" horizontal only.) * Horizontal and vertical "flow up"approval on all sizes Dimensions-Weights Models Sizes:1/2"–2" (15–50mm) A" A - , '�4� f mike, 0 r s B • *Subscript'S'=strainer model Suffix HC—Fire Hydrant Fittings dimension"A"=231/2"(594mm) MODEL SIZE(DN) DIMENSIONS WEIGHT A B C D F G R T in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. tA007QT 1 15 10 254 4% 117 27/6 62 — — 5 127 3% 85 25/6 59 2Y16 52 4.5 2 1-A007M30T 3/4 20 111/2 282 4 102 31/2 79 — — 63/6 157 31/46 87 21/2 54 15/s 33 5 2.3 tA007M1QT 1 25 131/4 337 51/2 130 4 102 — — 71/2 191 33/6 85 111/6 43 1 11/16 43 12 5.4 1-A007M2QT ,11/4 32 16% 416 5 127 35A6 84 — — 91/2 241 5 127 3 76 2 50 15 6.8 tA007M2QT 112 40 163/4 425 47/6 124 312 89 — — 9% 248 573/6 148 31/2 79 2116 68 15.9 7.2 1-A007M1QT 2 50 1912 495 61/4 159 4 102 — — 13% 340 61/2 156 37/6 87 211/46 68 25.7 11.7 • 00701.--S 12 15 13 330 6 152 27/6 62 3 76 5 127 3% 85 25A6 59 21/46 52 5.5 2.5 • 007M301-S 3/4 20 1412 368 61/2 156 316 79 3 76 63/s 157 31/46 87 216 54 15/16 33 6.7 3.1 • 007M10T-S 1 25 1715/6 157 7% 197 4 102 31 83 712 191 3% 85 1116 43 1116 43 14 6.4 • 007M201--S 114 32 2112 546 716 179 35/6 84 31 83 91/2 241 5 127 3 76 2 50 19 8.6 • 007M20T-S 11 40 2516 637 71/6 179 31 89 33/4 95 9% 248 513/6 148 31 79 211A6 68 19.6 8.9 • 007M1QT-S 2 50 273/4 692 83/4 222 4 102 4 102 13% 340 61 156 31/46 87 211/16 68 33.5 15.2 Dimensions-Weights Sizes:21/2"-3"(65-80mm) C(open) „ I 9"(229mm) AMPS ∎ . lII1IiIIf1°'i �! 45/,6'009mm) 0 o II. N E1 1 E 1 R M A Strainer Dimensions MODEL SIZE(DN) DIMENSIONS WEIGHT A C E,El R SIZE WEIGHT in. mm in. mm in. mm in. mm in. mm lbs. kgs. M N 007QT-FDA 21/2 65 331/8 841 63/8 162 91/2e 230 8% 222 155 70 in. mm in. mm in. mm lbs. kgs. • 007-NRS 21/2 65 331/2 841 9% 238 91/26 230 83/4 222 155 70 212 65 10 254 61/2 165 28 13 A• 007-0SY 21/2 65 331/2 841 16% 416 91/16 230 83/4 222 158 72 3* 80 101/2 267 7 178 34 15 007-QT-FDA 3 80 341/2 867 6% 162 9116 230 83/4 222 155 70 *S Models only A* 007-NRS 3 80 341/2 867 101 260 91/6 230 83/4 222 185 84 • 007-0SY . 3 80 341/2 867 18'/8 479 91/26 230 83/4 222 185 84 1"0007M1 QT Union Tailpiece _] Union Tailpiece Union Nut _ _ Union Nut ii'� ; jIIj1 ■,1!1��I!�' v l� � � I CI'I� III. li In — e F,Il "■ ■ A Sizes:lh"—2"(15—50mm) MODEL SIZE(DN) DIMENSIONS A in. mm in. mm 0007QT 1/2 15 1213/6 326 0007M2QT 3/4 20 1313/6 350 0007M2QT 1 25 16% 422 0007M2QT 11/4 32 203/4 527 0007M2QT 11 40 211/2 546 0007M1 QT 2 50 241/2 622 Capacity As complied from documented Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California lab tests. *Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) **UL rated flow 1/2"(15mm) 11/2"(40mm) bars psi * bars psi * o, .8 12 0,.8 12 ,_.7 10 2 .7 10 G ;v .5 8 _ ■ --ii.i■ .5 8 2 .3 4 in .3 4 ���. 1 2 La 0- 0 0 0. 0 0 0 2 4 6 8 10 12 gpm 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 0 38 76 114 152 190 228 66 304 342 380 418 456 Ipm 5 7.5 10 fps 5 7.5 10 15 fps 1.5 2.5 3.0 mps 1.5 2.5 3.0 4.5 mps Flow Flow bars psi a/4"(20mm) 2"(50mm) * 1.5 22 bars Rsd * .8 12 1.2 18 o..7 10 0 c.96 14 0.5 8 C] y `.4 3 46 .69 10 y o us 0 a`0 0 .1 2 d .41 6 0 25 50 75 100 125 150 175 200 gpm 0 95 190 285 380 475 570 665 760 Ipm .14 2 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 0 5 10 15 20 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm Flow 7.5 15 Ips 2.3 4.6 mps Flow 1"(25mm) 2W (65mm) bars psi 1.1 16 * nbars psi * ** .6 12 2.7 10 - 2 G .7 10 0.5 8 .5 8 y.4 6 - d .3 4 i.3 4 -- d .1 2 �- a.1 2 0 0 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 0 25 50 75 100 125 150 175 200 225 250 gpm 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 0 95 190 285 380 475 570 665 760 855 950 Ipm 5 7.5 10 15 fps 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 1.5 2.3 3.0 4.6 mps Flow Flow 11/4"(32mm) 3"(80mm) bars psi * bars psi 1 14 * ** .7 10 c o. .8 12 5 8 c .7 10 0.4 6 , .5 8 = .4 6 ,_.3 4 o .3 4 ...... y.1 2 d .1 2 / d0 0 a 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm 0 0 . - 0 95 190 285 380 475 570 665 760 855 950 1045 1140 1235 Ipm 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 5 7.5 10 fps 0 38 76 114 152 190 228 266 304 342 380 418 4561pm 1.5 2.3 3.0 mps 5 7.5 10 15 fos Flow 1.5 2.3 3.0 4.6 mps Flow WATTS® , � _ F9oo,_ZOOo a Ea • CERTIFIED A Watts Water Technologies Company USA: 815 Chestnut St.,No.Andover,MA 01845-6098;www.watts.com Canada: 5435 North Service Rd.,Burlington,ONT.L7L 5H7;www.wattscanada.ca ES-007 0830 ©2009 Watts 1... ''''' ."' '''' .... ,......00 **Vat ff. .glil...* P-011:0'6'..""".•:.:106,1*. 0 0,4,;',,,,,- II - ..."1, e 10 j, 7 IMP 1. flii vo. # 55 Series Galvanized Meter Boxes E ::: OVIE ER I : .: . 46,...... p with 28" dia. corrugated cans ,.........r. ..... Part no. Height Weight ,cP 47 "c=., # 55 A 18" 125 1 bs Da a n # 55 MS 18" 125 lbs ‘ ct sl 0 4001.1,44A11.....111114.0„______ ,.047047 ' % ‘t....... # 55 A2S 18" I 125 lbs .„.,:,, NT _ ______ # 55 B 24" 130 lbs - # 55 C 30" 135 lbs /11114400440mmisommiii # 55 D 36" 140 lbs # 55 E 42" 145 lbs # 55 F 48" 150 lbs . \\41414111111110mfteimma . 1111111111111111%01011.00001\44411411„ 10000000/ # 55 MS 18 ga. can - Dallas std SEWER: • PIPE o NORTH AMERICAN PIPE—SDR35 PVC PIPE,SDR26 CL160 PIPE o DIAMOND—SDR35 PVC PIPE,SDR26 CL160 PIPE • CASTINGS o BASS& HAYS—400 Series RING &COVER • FITTINGS o MULTI FITTING—TRENCH TOUGH GASKETED o CHARLOTTE PIPE—CLEANOUT PLUG • CONCRETE STRUCTURES o TURNER—METER VAULT, MANHOLES o CRETEX—CHIMNY SEALS ,.: North American Pipe Co Oration -- www.nolthamericanpipe.com Product Description: * l ASTM D3034 -:,,,,,--x - -.."1".1 .- f= , Gravity Sewer Pipe rs �1:4:1,,,,,, ,, - a North American Pipe's ASTM D3034 Gravity Sewer 4 v ; -"" PVC product line is manufactured to meet the %,,t,4,412.4 -` - ='t needs of modern municipal waste water systems, -7 ` residential waste water control and other non- r � pressure applications.With top quality raw v materials and modern processing technology North ' American Pipe's ASTM D3034 Gravity Sewer pipe ,. r rY ,� � meets all industry standards in addition to our own 'x • rigorous quality control standards. North American f ' Pipe's ASTM D3034 Gravity Sewer pipe utilizes i ' _ i _ ' �� Reiber style gaskets throughout the entire product offering. North American Pipe produces a full range of ASTM D3034Gravit Sewer pipe in SDR-35 and ,,,,,"7„...,"'"7� ,3 SDR-26 classifications.Whether specifying or �., installing our pipe you can be assured that North ,: i_ * American Pipe will provide the pipe"Right, On —4S) _ .' f �„. � Time,All the Time". This product is made in accordance with the following specifications: ASTM D3034 ASTM D1784 ASTM F477 ASTM D3212 Short Form Specification'; for North American Pipe Corporation ASTM 03034 Gravity Sewer Pipe ,-,4.., PVC gravity sewer pipe shall be made from a . . J compound conforming to a cell classification of 12454 or 12364 as defined by ASTM D1784 and in accordance with ASTM D3034 for sizes four inch through fifteen inch. The wall thickness,when tested according to ASTM D3412, shall correspond to a dimension ratio of SDR 35 with a pipe stiffness value of 46 or SDR26 with a pipe stiffness of 115 for °FiriY.0--1. heavy wall pipe. Integral bells shall incorporate Docked in gaskets meeting the requirements of ASTM D3212 and F477. The laying length of the pipe shall be 14 feet. Rev:01/2006 2801 Post Oak Blvd.I Suite 6001 Houston l TX 1 77056 Phone: 713-840-7473 Toll Free 800-999-7473 Fax: 713.552-0087 k North American e:Co oration www.northamericanpipe.com ASTM D3034 Gravity Sewer Pipe T — __..I. - .. C .... J 00 I BD NOMINAL OUTSIDE *APPROX.''' **APPROX INSERT PIPE SIZE DIA.-NOM. BELL DIA. .! BELL DEPTH MARK (OD) (BD) '(C) (L) 4" 4.215 5.25 4.27 3.250 6" 6.275 7.50 5.40 4.125 8" 8.400 10.00 6.27 4.250 10" 10.500 12.25 7.16 5.250 12" 12.500 14.25 8.04 5.500 15" 15.300 17.25 9.61 7.500 NOMINAL SDR 35 SDR 26 SDR 23.5 PIPE SIZE (T) (T) (T) 4" .120 .162 .178 6" .180 .241 .265 8" .240 .323 10" .300 .404 12" .360 .481 15" .437 .588 A Note:These dimensions are for estimating purposes only *Dimension given for Approx.Bell Diameter(BD)is for highest pressure class '*Nominal depth,depth will vary by pressure class Rev:01/2006 2801 Post Oak Blvd.I Suite 6001 Houston I TX j 77056 Phone: 713-840-7473 Toll Free 800-999-7473 Fax 713-552-0087 North American . ilPipeCorpwatio.n . .. , _ www,northamericanpipe.com Product Description: 9. t 14 af ' ' ASTM D2241 7 , . 5f''' IPS Gasketed Pipe North American Pipe's IPS-Gasketed product line 1 a " , is manufactured to meet the needs of water a .� -. distribution systems,irrigation systems and other �r I a applications requiring ASTM D2241 piping t'' x ; �,, systems.With top quality raw materials and ' , ,_ 1 ;� modern processing technology North American .r� �, Pipe's IPS-Gasketed pipe meets all industry r �' ; 1Z standards in addition to our own rigorous quality m i' .. = control standards. North American Pipe's IPS- " °, < Gasketed pipe utilizes Reber style gaskets '1 ,^ ; throughout the entire product offering. North q;r a� _� American Pipe produces a broad range of IPS pipe ' i,' ..;.�,, ; ,emu ' in SDR-13.5,SDR-17, SDR-21,SDR-26,SDR-32.5 ;sr 4,,,, ,,,--- k, and SDR-41 classifications.Whether specifying or ,; installing our pipe you can be assured that North _- ' American Pipe will provide the pipe"Right, On A, ,. _ .„" Time,All the Time". This product is made in accordance with the following specifications: ASTM D2241 ASTM D1784 ASTM D3139 ASTM F477 ANSI/NSF 14 ANSI/NSF 61 Short Form Specification for North American Pipe Corporation ASTM 0 2241 IPS Gasketed Water distribution pipe shall be made in accordance , s t1N' 13e1)with ASTM D2241 from a compound conforming to flfl of riarv.+rwnAk a cell classification of 12454 as defined by ASTM D1784. Integral bells shall incorporate gaskets meeting the requirements of ASTM F477 and be locked into the bell. The assembled gasketed joint shall meet the requirements of ASTM D3139. The 0 pipe and gasket must be tested and approved for contact with potable water in accordance with ANSI/NSF 61 and NSF 14. Rev:09/2008 2801 Post Oak Blvd.j Suite 600 I Houston j TX j 77056 Phone: 713-840-7473 Toll Free 800-999-7473 Fax: 713-552-0087 North American stiF .Pi eA Car aration _. -. www.northamericanpipe.com ASTM 02241 IPS Gasketed Pipe T L c s NOMINAL OUTSIDE. 'APPROX. "APPROX.`' INSERT PIPE SIZE DIA.-NOM.. BELL DIA. BELL DEPTH MARK (OD) (BD) (C) (L) 1* 1.900 2.25 3.56 2.63 2" 2.375 3.00 3.76 2.63 2'/" 2.875 3.50 4.48 3.38 3" 3.500 4.50 4.82 3.63 4" 4.500 6.00 5.34 4.13 5" 5.563 7.50 6.48 5.00 6" 6.625 8.25 7.30 5.63 8" 8.625 10.75 8.62 6.38 10" 10.750 13.50 9.20 7.00 12" 12.750 15.75 10.27 8.00 14" 14.000 17.25 11.91 8.88 16" 16.000 19.75 12.24 9.13 18" 18.000 22.00 15.13 11.13 NOMINAL PR,100 PR 125 " PR 160 PR 200 PR 250 PR 315 PIPE SIZE SDR 41 SDR 32.5 SDR 26 SDR 21 SDR 17 SDR 13.5 (T) (T) (T) (fl (T) (T) 1'/2" .060 .073 .090 .112 .141 2" .073 .091 .113 .140 .176 2'/" .088 .110 .137 .169 .213 3" .085 .108 .135 .167 .206 .259 4" .110 .138 .173 .214 .265 .333 5" .136 .171 .214 .265 .327 .412 6" .162 .204 .255 f,, .316 .390 .491 8" .210 .265 .332 .410 .508 10" .262 .331 .413 .511 .632 12" .311 .392 .490 .606 .750 14" .538 .666 16" .615 .762 18" .857 Note:These dimensions are for estimating purposes only •Dimension given for Approx.Bell Diameter(BD)is for highest pressure class ••Nominal depth,depth will vary by pressure class Rev:09/2008 2801 Post Oak Blvd.I Suite 600 I Houston I TX 1 77056 Phone:, 713-840-7473 Toll Free 800-999-7473 Fax 713-552-0087 4 P'`:"''''-,,,-: -!-7 , _-- -- - - -- , ,, ''k6,-- 1 , ,...., 2 --"'-----n--ant-. 1 Sa n i •-21 TM:PVC Sewer Pipe ,q SPECIFICATION DATA ' n{ yit.... ,# . C Diamond gravity sewer pipe 4 inches ` through 48 inches shall be made of .A` `�a. ` `i,'4^ ' r s' compounds conforming to material S r - �,' � t ,,p� 1i . requirements of ASTM D3034 and , 4, _ t T" ASTM F679 in accordance with ..t t, F �P ASTM D1784.Diamond PVC Sewer * err ° ', ,,, Pipe meets all the dimensional, '' b . � chemical,and physical requirements as . . '� .'5,-1),„,,i,..1.,-,; ,pi outlined in ASTM D3034 and ASTM F679. k t. 4""T„. �,�" rte'` % '.., � The pipe sizes 4 inches through 48 inches f F t :< ai, �: are made with an integral bell �� �#t , 4`, , .". `, ' .` "water-tight"joint that meets the r -. r 40. ` v requirements of ASTM D3212 and that .� ' <i, �-. '.4 ��` �, utilizes a Rieber gasket system for - ti _ ; ..:t.1, a° . , sealing that meets the requirements ''„ x. _.Wt � �' Xaxbx of ASTM F477. Each male end shall be beveled to facilitate joining and referencing marked for proper insertion depth.Diamond furnished lubricant is to be used in the joining process. Physical Properties of ASTM D3034&F679 - - A - Pipe Stiffness Pipe Materials: Pipe Modulus Pipe shall be made of PVC plastic having a minimum cell classification of 12454 or 12364 as defined in Specification SDR E= 400,000 E=500,000 D1784. 41 28 35 Property ASTM Minimum 35 46 57 Test 26 115 144 Specific Gravity D792 1.40 Standard laying lengths are 14 and 22?feet Tensile Strength,psi D638 7,000 Tensile Modulus,psi D638 400,000 IZOD Impact Strength, D256 .65ft.,lb./in. SHORT FORM Specification for Diamond PVC Solid-Wall Sewer Pipe SDR 26 or SDR 35 or PS 46 or PS 115 Diamond PVC Solid-Wall Sewer Pipe shall be made of compounds conforming to ASTM D1784 manufactured in accordance with the material requirements of ASTM D3034 or ASTM F679.Diamond PVC Sewer Pipe must meet all dimensional,chemical,and physical requirements as outlined in ASTM D3034 orASTM F679.Diamond PVC Sewer Pipe shall be installed according to the requirements of ASTM D2321.Joints shall meet the requirements of ASTM D3212 and shall be formed using Rieber Technology.Uni-Bell UNI-PUB 6,"and the manufacturer's requirements." ,r N; wcaze.sa, y DIAMOND PLASTICS® Corporate Headquarters• 1212 Johnstown Road •P.O.Box 1608•Grand lsland,NE68802-1608 `"4 i` : - .. .. � ra lg�w ��! .�; .�i�l¢ ��—�' _ ..emu-'.�,°� � � � ._ ?. =� qtr, ---- - - ./s„ Sani-21 :PVC Sewer Pipe - ,_,,_ _ , --_-: 'vs° SPECIF■LAI iui\I DAIA ,.,„. .,-' ,,. , • , `.- ''t j ' III ' ' '■'' Reiber Joint Illustration ,...,,, „.....,,,, .;.,,,.., „....i.,,,z. , 4•. - 4- -..-4,73...4i;-;,; 47.72;7' '49,°;;M, 1,'.:.,..-.."-' ; lit -vissriiiwt.4.„,,,,.. 7 .7-7:771-- I ,4 ,.,,,,-,,-,,-- = - 1 --24.4,-.. .1 III .1.,,,,-,,,,, , 11;1 s.%14.!:./•.: ,.%' • , < -, f..., '.:, '4.-- ,, e ' 4,. . , . .., 4 ...4+..YPee: .....e. It 11 „`..f*$.e,1 '''''...". P■ =- - " hl ".4-44e4:4t.,1 ' : f ' 4111''' ::•.,::".. efirgl .. .. .. .. ...„ t...4t..., ..-c,,„:... .4. ... 21141411 1:1:,'.44. ti-r,,,,; “ is ster)plied;t1 '1, -..' '''...; '.4.r,.5•1 742 foot!ay ivg'o,,,3,1',,r,fh,',,,. ',,,-,s:-T•r,,a,. ' ;.-= D3034&F679 SEWER SPECIFICATION DATA firrxv-i S U.Ul 1 ',, ` -,,7,-, - ,, ,,, /,, .,-,',,'„,„; - ■ 4'1 i;.t,,,,,,,,,,,4,1-'4`., 1,h,,p14.'-:,+-' ,.,',,,,k-r,,,,. ' ,,,,,,-,,,; ''..,f ---( , ,,,:;", ,',..,f4 , , 4 4f; ;'; 4,"''44'`4 ' ' '- " ''. '"'..''', '1-i'-`'''..,;:',-f•-. 111-,I,J, '-, " 4 4.215 5-1/4 4-5/8" 4" 0.162 0.120 6 6.275 7-1/2 4-3/4" 4" 0.241 0.180 8 8.400 9-7/8 6-1/8" 5" 0.323 0.240 10 10.500 12-3/8 6-3/4" 6" 0.404 0.300 12 12.500 14-5/8 7-1/4" 6" 0.481 0.360 15 15.300 18 6-3/4" 6" 0.588 0.437 18 18.701 21-3/4" 7-3/4" 7" 0.671 0.499 21 22.047 25-1/2" 7-3/4" 7" 0.791 0.588 24 24.803 28-3/4" 8-1/2" 7-1/4" 0.889 0.661 27 27.953 32-1/2" 8-1/2" 7-1/4" 1.002 0.745 30 ciod 32.000 37-1/4" 12" 10" 1.148 0.853 36 ciod 38.300 43-1/4" 12" 10" 1.373 1.021 42 ciod 44.500 53" 16" 13" 1.187 48 clod 50.800 60" 16" 13" 1.355 'Possession of this page does not constitute an offer of sale' _i Prices are subject to a firm policy of"Price in effect at time of shipment on regular purchases" , ‘ DIAMOND , 2 PLASTICS® ,, „ R • ,, Corporate Headquarters• 1212 Johnstown Road•P.O.Box 1608•Grand Island,NE 68802-1608 4--,'`..J.:-';,'.::',4;,':.4.7,-:...!:';',F,:::::,;,,,',.;t4--:,-.).',,,,-5;,,s,;..:Li,-;-$',5i.:1-si,...,,-..-,f;,-,, ".A J a g 3 4 �224� : IPS PVC Pressure Pipe ,/SPECIFICATION DATA Diamond IPS pressure rated PVC pipex � '; � is made of compounds conforming toy material requirements of ASTM D2241 ti ,� in accordance with ASTM D1784. 4` � � � , ,° fl Pipe sizes (1 'h"through 12")are � � made with an integral bell to utilize the � � ,r Rieber gasket system for sealing,and °' meeting specifications defined in ASTM F477. ; � ��, � er` Diamond IPS pressure rated PVC pipe >°,. 44'� 7 d meets all the dimensional,chemical, 'Is' and physical requirements as outlined in y , ASTM D2241.Potable water pipe �, ��' carries the mark of NSF,International in � ;: . , accordance with Standard 61. Each male end shall be beveled to facilitate joining and reference marked to insure proper insertion depth. Diamond furnished lubricant is to be used in the joining process. Physical Properties of PVC 12454: 0 Property ASTM Minimum Test Specific Gravity D792 1.40 Tensile Strength,psi D638 7,000 Tensile Modulus,psi D638 400,000 IZOD Impact Strength, D256 .65ft.,lb./in. SHORT FORM Specification for Diamond PVC Water Pipe Diamond PVC Water Pipe shall be made of compounds conforming to ASTM D1784 with a cell classification of 12454.Diamond PVC Water Pipe must meet all the dimensional,chemical,and physical requirements as outlined in ASTM D2241 and will be supplied in 22 foot laying lengths.Joints shall be formed using Rieber Technology.Potable water pipe shall be manufactured from NSF listed ingredients. DIAMOND ' PLASTICS® ��" b IEEPI M Corporate Headquarters• 1212 Johnstown Road•P.O.Box 1608•Grand Island,NE 68802-1608 a; D2�41 : IPs PVC Pressure Pipe ^,,;" �`�,, , v SPECIFICATION DATA g i D C Reiber 1 �I� Joint A B Illustration i -..#L-64,141,,Z,6,,'---'L ,c...t - r ▪ .3 SPECIFICATION DATA Rural Ii ▪ ? f C' I Y'`s 4 i .ayr,' a Ga G ,y ,x 1.5" 4" 4-1/4" 2-7/8" 2" 2-1/2" 4" 3-1/8" 2.5" 4-1/4" 5" 4-3/8" 3" 3" 4-1/2" 4-7/16" 4" 3-1/2" 4-3/4" 5-1/2" Minimum Wall 6" 5" 5-1/2" 8-1/4" Thickness-(t) 8" 5" 6" 10-1/4" - 10" 5-1/2" 6-1/2" 12-7/8" 12" 5-3/4" 7" 15-1/8" `±a as a " r ' .M 1 .Dad e (d 4,,,,f3'-t;jy n, 'Z1"", 7, a r ,�` + '� t F Sr S ' Ifs ,,zt, r a P rr} �1 '','.;,_'';',--' '.; .. .r'' ,;',":::„.-,',,7".,,;-:-',:',-:-:,:::rr?''''''''';',1 - - "' V ' '''''''' '''' '' -- - '' ' 1.5" 1.900 0.141 0.112 0.090 2" 2.375 0.176 0.140 0.113 0.091 2.5" 2.875 0.213 0.169 0.137 0.110 3" 3.500 0.259 0.206 0.167 0.135 4" 4.500 0.333 0.265 0.214 0.173 0.138 0.110 6" 6.625 0.491 0.390 0.316 0.255 0.204 0.162 8" 8.625 0.508 0.410 0.332 0.265 0.210 10" 10.750 0.632 0.511 0.413 0.331 0.262 12" 12.750 0.750 0.606 0.490 0.392 0.311 "Possession of this page does not constitute an offer of sate" DIAMOND .` PLASTICS® . 0 -, . c; , ., , l 0 r, Corporate Headquarters• 1212 Johnstown Road•P.O.Box 1608•Grand Island,NE 68802-1608 xp 7/8 k (22mm) LIFTING HOLE 1. 13/16 (352rnm) RAD _2_14114111140. 1 1• 32mm} LETTERING RECESSED" FLUSH — ' ,- \4"\. ,*, ...., Ai e H illi ai i 'yi 2' . 1. .� ((Liii 1 [5imrn] :"aril W III ITO ON 1 ,,,,i ■li I ll Iliti SEE PICK BAR�/ RETAIL .2024A . r 9T 20241 1 1 4..' 32rn LETTERING. RE SSE b. FLU H BOTTOM VIEW OF COVER 24" DR [810mrn] 3 3/4" 1 1 7%8" t/¢" 1„ 2 1/2" ['9Smrn] [48mrn] [6mrn] — [25mrn] [ [64rnm] , * II '' W+ �it�I� t/ /o} #fir. Mi. COVER SECTION 2 t3/16"i 1" 25rtim} [71rnrn] DIA ' S BAR 2 13/16" DIA [71mm] [860rnrn] 2 rnn PICT BAR DETAIL [63mm] 24 1/4" DR il [616mrn] ' [152r, 7m] q MACHINED SURFACE 'i I 22 1/6" DIA _ BH 400-24 [562m m] 31" DR COVER: 1q0 LBS 86kg [7E7mrn] .. FRAME: 225 LEIS 102kg 3/4" UNIT: 415 LBS 18 kg RING SECTION [19mrn] ii ` 1 MULTI FITTINGS HIGHER STx1NDARDS' it j r ."Tf ',1 ,..,.;,44.,.. ..,-,'',40,t,i44-'14.0;i11.1.'..c..z.-,:'...,—e0.11°'::'.,:,'1f.,.`:.l:„9',l,,.1:.<,r„t,.;,-..,:.e,i.,4,:,‘,.'.-•--i,*.7.,i-f,i,,. ;;ig ,'4,.f,0,, . + EiJ ,,,,„..:;,,,.;:,„.,. .....„,i,i,..w.,4i.,,tfr,k A.4.1,,,,,,,.:04.:1„,L,-.-,44 ,4.4-4,,e,,. ,' , 4,.,., ..!, .. ., - , .,,,4:,,,,,,4,.., 4 :q.'F:4t:;;:::.)::ti,j,...,ie:",;kfr4:.''j:-:iI.,:,4-;-zf:;,;;::t:;-;;%:''i:::.,..,:.:it:ir4t!:.:g;-.t'::7fr::,„4:,:I...-:'4,':r7::i;r:;:41:,:<,,t':it7:1:-..;':7.1417`,-":-::171.:.eta # • `. '' 1 a S t 4 f Committed to �� � HIGHER T'ANDARD i ;. 1' itio www. na fifitiincs.cam I TRENCH TOUGH PIIJSTM GASKETED SDR35 SEWER FITTINGS Injection Molded * Ideal for rise in wastewater, stormwater and industrial waste applications. * Reinforced to SDR26. thickness at key locations Fabricated ated such as the branches of tees and wy�es for optimal long-term performance. ,,, ,i 12"-48" � *"t .t Y' * Joint withstands 15 psi hydrostatic pressure r ' � `- `` and a -10.8 psi vacuum pressure. �� 17.1 " r * Leak-proof at 5'joint deflection and 5°l ''''',..:.f.?,',,,:k�- ring deflection, 40 sA• 4 TRENCH TOUGH PLUS' .w� .. LARGE DIAMETER MOLDED SDR35 .`;_., SEWER FITTINGS Injection +/ * Multi is the only manufacturer to offer.12' and 15" -Molded :- 12"-15" „,,, molded fittings. t 1. * Designed to exceed all applicable standards and * r � 1 are built to withstand higher impact forces, higher ; a . ,. d jobsite conditions. #1 z` * Reinforcc:I at key intersecting locations for added r� �,,- s:rength without losing flexibility. `l0 o TRENCH rl`OIJ( H PLUSM HEAVY WALL SDR2fi GASKETED Injection SEWER FITTINGS Molded 4"-12 * Compatible with SDR26 and SDR35 sewer pipe and are used in areas where the installation ti conditions are more chat=engine such as Jeep Fabricated burial applications or projects in poor soils. 12"-18" a Service fittings are manufactured with an `extra heavy wail" SDR24 thickness. * Easily identfiable with its grey gaskets. PVC SEWER FITTINGS 1 5 !! !,11U . SPECIFICATION CHART SEWER FITTINGS OPTIONS SIZE RANGE REFERENCED STANDARDS ' INJECTMN MOLDED: ASTM D3034, F679, F170 --- Trench Tough Plus ' , up to 15° CSA B182 2 Gasketed Fittings SDR35 : - 4,1 FA8RICATE°' CSA S1812 up to 42' IAPMO File 2451 INJECTION MOLDED: 74741 Trench Tough Plus up to 12' S0R26 ASTM 03034, F679, F170 7tlisi Gasketed Heavy Wall FABRICATED: Zig,'-''''' up to 27' .. ="R ,... 1N.ILC I ION MOLDED: • .-. Dli51 p 23 . AWWA-C900 4'-8°(DR18) MOD Sewer Fittings DR411 ' DR18 , _F ' AWWA 0907 ABRICATED- ' 1 DR32.5 DR14 NNW%C905 ' I NJ LIG=ION MOLDED: 3'-tr ASTM D2665(6"&8") = ' Solvent Weld SDR35 NSF 14 (6'&8') FABR:CAI LO: CSA 8181.2(6"&8') 8' 15' ASTM F794 Ultra-Rib Open Profile -, 8° 24' AASHTO M304 CSA B182.4 • ASTM D3034 INit_c ,ON MOLDED: • . '- " DWV Schedule 40 PVC PVC 6 12 CSA, IAPM0, NSF FABRICATED: 10" -24" ABS ' .t.:0 Backwater Valves 3 b, . -6' CSA, IAPMO, NSF, S8C .• PRESSURE FITTINGS OPTIONS ' . SIZE RANGE ' . REFERENCED STANDARDS AWWA CO&C905 (Fabricated Fittings) DR 51 i : IN EcTioN Motom: AWWA C907 Blue Brute DR 41 ' 4'-8" (DR 18) (Molded Fitting ) C9001C905/C907 CIOD DR 32.5 . GSA 13137.2 DR 25 : FABRICATED: (Molded Fittings) DR 18 "' IC"- 48° CSA 8 137.3 (Fabricated Fittings) DR 14 Factory Mutual (4"- 12") Underwriter's Laboratories INJECTION MOLDED: Cycle Tou h l'h"-8° ASTM D1784,D3139,D1599, g ---- 02241,F477 Pressure Fittings for DR 21 CSA B137.3 Series 200 IPS Pipe FAsa CAT ED: NSF-61 41 10"-24' 10 I EASY SPECIFICATION CHART CHARL• PIPE AND FOUNDRY COMPANY Suggested Specification System: PVC Schedule 40 Pressure Pipe and Fitting System Scope: This specification covers PVC Schedule 40 pipe and fittings for pressure applications. This system is intended for pressure applications where the operating temperature will not exceed 140°F. Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a Cell Class of 12454 as identified in ASTM D 1784. PVC Schedule 40 pipe shall be Iron Pipe Size (IPS) conforming to ASTM D 1785. PVC Schedule 40 fittings shall conform to ASTM D 2466. Pipe and fittings shall be manufactured as a system and be the product of one manufacturer. All pipe and fittings shall be manufactured in the United States. Pipe and fittings shall conform to National Sanitation Foundation (NSF) Standard 61 or the health effects portion of NSF Standard 14. Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall conform to all local plumbing, building, and fire code requirements. Buried pipe shall be installed in accordance with ASTM F 1668. Solvent cement joints shall be made in a two step process with primer manufactured for thermoplastic piping systems and solvent cement conforming to ASTM D 2564. The system shall be protected from chemical agents, fire stopping materials, thread sealant, plasticized vinyl products, or other aggressive chemical agents not compatible with PVC compounds. Systems shall be hydrostatically tested after installation. WARNING! Never test with or transport/store compressed air or gas in PVC pipe or fittings. Referenced Standards: ASTM D 1784 Rigid Vinyl Compounds ASTM D 1785 PVC Plastic Pipe, Schedule 40 ASTM D 2466 PVC Plastic Fittings, Schedule 40 ASTM D 2564 Solvent Cements for PVC Pipe and Fittings ASTM F 1668 Procedures for Buried Plastic Pipe NSF Standard 14 Plastic Piping Components and Related Materials NSF Standard 61 Drinking Water System Components - Health Effects Note: Latest revision of each standard applies. (110) PO Box 35430 Charlotte,NC 28235 USA 704/372-5030 800/438-6091 FAX 800/553-1605 www.charlottepipe.com Designation: F 758-95 (Reapproved 2000)a�r An American National Standard � INTERNATIONAL Standard Specification for Smooth-Wall Poly(Vinyl Chloride) (PVC) Plastic Underdrain Systems for Highway, Airport, and Similar Drainage1 This standard is issued under the fixed designation F 758;the number immediately following the designation indicates the year of original adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.A superscript epsilon(e)indicates an editorial change since the last revision or reapproval. This standard has been approved for use by agencies of the Department of Defense. 1. Scope D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) 1.1 This specification covers the requirements for smooth- Compounds and Chlorinated Poly(Vinyl Chloride) wall perforated and nonperforated poly(vinyl chloride) (PVC) (CPVC) Compounds3 plastic pipe and couplings for use in subsurface drainage D 2122 Test Method for Determining Dimensions of Ther- systems of highways, airports, and similar applications in moplastic Pipe and Fittings4 nominal sizes of 4,6,and 8 in.and in pipe stiffnesses (PS) that D 2152 Test Method for Degree of Fusion of Extruded are designated as Type PS 28 and Type PS 46 in accordance Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by with its minimum pipe stiffness. Acetone Immersion4 1.2 Molded fittings for use with highway underdrain pipe D 2321 Practice for Underground Installation of Flexible are in accordance with Specification D 3034.For convenience, Thermoplastic Sewer Pipe" some of these fittings are reproduced in Annex A 1. D 2412 Test Method for Determination of External Loading 1.3 The values stated in inch-pound units are to be regarded Characteristics of Plastic Pipe by Parallel-Plate Loading' as the standard. The values given in parentheses are for D 2444 Test Method for Impact Resistance of Thermoplas- information only. tic Pipe and Fittings by Means of a Tup (Falling Weight)4 D 2564 Specification for Solvent Cements for Poly(Vinyl • NOTE 1—Type PS 28 and Type PS 46 indicate"pipe stiffness"of 28 and Chloride) (PVC) Plastic Piping Systems4 46,respectively,as outlined in 11.1. D 2855 Practice for Making Solvent-Cemented Joints with NOTE 2—Pipe and fittings should be installed in accordance with Practice D 2321,or applicable state or local specifications. Poly(Vinyl Chloride) (PVC) Pipe and Fittings4 D 3034 Specification for Type PSM Poly(Vinyl Chloride) 1.4 The following safety hazards caveat pertains only to the (PVC) Sewer Pipe and Fittings4 test methods portion, Section 11, of this specification: This D 3212 Specification for Joints for Drain and Sewer Plastic standard does not purport to address all of the safety concerns, Pipes Using Flexible Elastomeric Seals' if any,associated with its use.It is the responsibility of the user D 4396 Specification for Rigid Poly(Vinyl Chloride) (PVC) of this standard to establish appropriate safety and health and Related Plastic Compounds for Non-Pressure Piping practices and determine the applicability of regulatory limita- Products5 bons prior to use. F 402 Practice for Safe Handling of Solvent 2. Referenced Documents Cements,4Primers,and Cleaners Used for Joining Thermo- 2.1 ASTM Standards: plastic Pipe and Fittings4 D 618 Practice for Conditioning Plastics and Electrical F 412 Terminology Relating to Plastic Piping Systems4 2.2 Federal Standard: Insulating Materials for Testing2 Fed.Std.No. 123 Marking for Shipments (Civil Agencies)6 D 1600 Terminology for Abbreviated Terms Relating to 2.3 Military Standard: Plastics MIL-STD-129 Marking for Shipment and Storages 'This specification is under the jurisdiction of ASTM Committee F-17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.65 on Land 'Annual Book of ASTM Standards,Vol 08.02. Drainage. 4 Annual Book of ASTM Standards,Vol 08.04. Current edition approved Sept. 10,1995.Published November 1995.Originally s Annual Book of ASTM Standards,Vol 08.03. published as F 758-82.Last previous edition F 758-93. 6 Available from Standardization Documents Order Desk,Bldg.4 Section D,700 2Annual Book of ASTM Standards,Vol 08.01. • Robbins Ave.,Philadelphia,PA 19111-5094,Attn:NPODS. Copyright C ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959,United States. 1 Convright by ASTM Intl(all right.%reservedl• ' ill'' F 758-95 (2000) 3. Terminology TABLE 2 Dimensions of Bends 3.1 Definitions-Definitions are in accordance with Termi- 'J r nology F 412, and abbreviations are in accordance with Ter- f minology D 1600,unless otherwise specified.The abbreviation 4 � for poly(vinyl chloride) plastic is PVC. .7 4. Classification \/45° R 4.1 Two classes (or pipe stiffness) are included and desig- L M \\:}. n + nated as PS 28 and PS 46 as determined in accordance with r T- 11.1. 5. Materials in. 5.1 The pipe shall be made of PVC plastic having a Socket Length of P P g DepthA Tangent Nominal minimum cell classification of 12454 or 12364 as defined in Size,in. Angle Radius Dimen-sion Dimen-sion Specification D .1784 or a minimum cell classification of 11432 J,min L,min or 11332 as defined in specification D 4396. Homopolymer 4 45° 16,24,36 1.750 2.00 PVC compounds must equal or exceed the requirements of the 90° 16,24,36 listed cell classification numbers. 6 45° 24,36 3.000 3.50 5.2 Rework Material-Rework material from the manufac- 90° 24,36 turer's own pipe or fittings production may be used by the same 8 90° 24,36 4.000 5.00 manufacturer, provided that the pipe or fabricated fittings so° 24,36 produced meet all the requirements of this specification. mm 6. Joint Systems Socket Length of Nominal DepthA Tangent 6.1 Gasket-Type Joints,meeting the applicable requirements Size,in. Angle Radius Dimen-sion Dimen-sion of Specification D 3212, may be utilized. J,min L,min 6.2 Solvent-Cement-Type Joints, made with bell ends meet- 4 45° 406.4 609.6 914.4 44.44 50.80 ing the requirements of Table 1.; stop-type couplings in 90° 406.4 609.6 .914.4 conformance with Table 2; or sleeve-type couplings in con- 6 as° 609.6 914.4 76.20 88.90 formance with Table 3, may be utilized. 90° 609.6 914.4 6.2.1 Belled ends shall be formed so as to provide a uniform 8 45° 609.6 914.4 101.60 127.00 shoulder around the entire circumference of the pipe. 90° 609.6 914.4 ASocket dimensions shall be as shown in Table 1. TABLE 1 Socket-Type Bell Dimensions (Belled Ends for Solvent-Cement-Type Pipe and Bends) 6.2.2 Solvent-cemented joints shall be made using PVC cement meeting the requirements of Specification D 2564,and shall be made in accordance with Practice D 2855 and Practice A F 402. 7. Requirements Requirements in. 7.1 Workmanship-The pipe shall be homogeneous B c throughout and essentially uniform in color, opacity, density, Nominal A Socket Bell and other properties. The inside and outside surfaces shall be Size,in. Entrance Depth, Bottom min semimatte or glossy in appearance (depending on the type of 4 4.235±0.009 4.210±0.009 1.750 plastic) and free of chalking, sticky, or tacky material. The 6 6.305±0.011 6.270±0.011 3.000 surfaces shall be free of excessive bloom, that is,slight bloom B 8.424-0.012 8.388±0.012 4.000 is acceptable. The pipe walls shall be free of cracks, holes, mm blisters, voids, foreign inclusion, or other defects that are c visible to the naked eye and that may affect the wall integrity. Nominal A B Bell Holes deliberately placed in perforated pipe are acceptable. Size,in. Entrance Socket Depth, Bloom or chalking may develop in pipe exposed to direct rays min of the sun (ultraviolet radiant energy) for extended periods and 4 107.57 y 0.22 106.93±0.22 44.44 consequently these requirements do not apply to pipe after 6 160.15±0.28 159.26±0.28 71.20 extended exposure to direct rays of the sun. 8 213.97±0.30 213.06±0.30 101.60 P Y 7.2 Dimensions and Tolerance: 2 Cnnvrioht by ASTM Tnt'I(a11 riohte rrerrvrril• 4 F 758-95 (2000) TABLE 3 Sleeve Coupling Dimensions TABLE 5 Perforations^ '9 1 t MARKING ti ,..I 1111- I in. Nominal C e Dimension t, Pipe Size, Dimension A Dimension B * r•M min B LON g I �p•_3° BEGOW 4 3.5±0.250 4.230±0.005 0.120 �i� 6 6.0±0.250 6.291 ±0.005 0.180 8 8.0±0.250 8.418±0.006 0.240 90, TO mm X20• Nominal Dimension t, Pipe Size, Dimension A Dimension B in. min Nominal Minimum Hole Size^ Hole Spacing^ Diameter, 4 88.8±6.34 107.44±0.13 3.05 in. of Perfo- mm in, mm in. 6 152.4±6.34 159.77±0.13 4.57 rations 8 203.2±6.34 213.74±0.15 6.10 4 2 4.8 to 9.7 3/16 to 82.55±6.35 31/4 3/8 1/4 6 4 4.8 to 9.7 3/16 to 82.55±6.35 31/41 3/8 1/4 7.2.1 Outside Diameter-The outside diameter and toler- 8 4 4.8 to 9.7 3/16 to 82.55±6.35 3 1/4 ances shall meet the requirements of Table 4 when measured in 3/8 1/4 accordance with Test Method D 2122. The tolerances for 'Combination of hole size and spacing of holes shall provide a minimum inlet out-of-roundness shall apply to pipe prior to shipment. area greater than 0.2200 in 2/ft of pipe(that is,3/,s-in.holes at 3-in.center would 7.2.2 Wall Thickness-The actual wall thickness of pipe permit a 0.2206-in.2 area). shall be the wall required to meet the physical requirements of this specification but not less than that shown in'Table 4 when meric seal joints shall meet dimensions recommended by the measured in accordance with Test Method D 2122. manufacturer. The thickness of the wall shall be considered 7.2.3 Length-Laying length shall be 20 ft (6.1 m) (or as satisfactory if the bell was formed from pipe meeting the mutually agreed upon between the purchaser and the manufac- requirements of this specification. turer).A tolerance of-!-1 in. (±25 mm) shall be permitted. 7.2.6 Sleeve-Type Coupling Dimensions-Dimensions shall 7.2.4 Perforations-Perforated pipe shall be perforated in be in accordance with Table 3. Sleeve-type couplings shall accordance with Table 5. The perforations shall be approxi- have a wall thickness not less than that required for pipe and mately circular and cleanly cut. The spigot end, and bell, of shall meet the requirements of Section 8. belled-end pipe may be unperforated for a length equal to the 7.2.7 Fitting Dimensions: depth of the socket or shoulder, or both. 7.2.7.1 Molded Fittings-See Annex Al. 7.2.5 Integral Bell Dimensions-Integral bell dimensions of 7.2.7.2 Fabricated fittings are acceptable provided they are pipe, bends, and sweeps shall comply with Table 1. Elasto- made from pipe that meets or exceeds all of the applicable requirements of this specification. TABLE 4 Pipe Dimensions 7.2.8 Bend Dimensions: 7.2.8.1 The dimensions for bends shall be as shown in Table in. 6. Nominal Outside Diameter Minimum Wall Thickness 7.2.8.2 The thickness of the wall shall be considered sails- Size, Average Out-of-Roundness' Type Type factory if the bend was formed from Type PS 46 pipe that in. Tolerance min max PS 28 PS 46 meets the requirements of this specification. 4 4.215±0.009 4.165 4.265 0.103 0.120 6 6.275±0.011 6.225 6.325 0.153 0.180 8 8.400±0.012 8.325 8.475 0.205 0.240 TABLE 6 Pipe Stiffness (Minimum Pipe Stiffness at 5%Deflection(F/oy)) mm Pipe Stiffness, Pipe Stiffness, Nominal Outside Diameter Minimum Wall Thickness Nominal kPa bf/in.-in. Size, Average Out-of-Roundness^ Type Type Pipe in. Tolerance min max PS 28 PS 46 Size,in. Type Type Type Type PS 28 PS 46 PS 28 PS 46 4 107.06±0.22 105.80 108.34 2.62 3.05 4 190 320 28 46 6 159.38±0.28 158.12 160.66 3.88 4.57 6 190 320 28 46 8 213.36±0.30 212.08 214.62 5.20 6.10 8 190 320 28 46 'The tolerance for out-of-roundness applies only at the time of production. 3 Coro/right by ASTM Intl(all rights reservedl- " iii F 758—95 (2000) 8. Performance Requirements 10.2.1 For quality control tests, specimens shall be condi- 8.1 General: tioned for a minimum of 3 h in air,or 1 h in liquid at 23 ± 2°C. 8.1.1 Pipe Stiffness—The pipe stiffness (F/DY) values shall They shall be tested at 23 ± 2°C without regard to relative be in conformance with Table 6, when tested in accordance humidity. with 7.1.1. 10.2.2 For the impact test,specimens shall be conditioned at 8.2 Quality Control: 0 to 1.6°C for at least 1 h in liquid or other suitable means to 8.2.1 Scope—The tests in this section are producer's quality obtain thermal equilibrium. control tests and are not intended for simulated service tests. 8.2.2 Impact Strength—The minimum drop weight impact 11. Test Methods strength values for pipe and fabricated fittings shall be as given 11.1 Pipe Stiffness—Determine the pipe stiffness at 5 in Table 7, when tested in accordance with 11.2. deflection using Test Method D 2412. Test three specimens NOTE 3-Development of a test for molded fittings is under study by each 6 ± 'As in. (150 ± 2 mm) long and determine the average ASTM.Requirements will be included when available. pipe stiffness at 5%deflection in accordance with 9.1.9 of Test 8.2.3 Pipe Flattening—When examined without the use of Method D 2412. The pipe stiffness shall equal or exceed the magnification equipment, there shall be no evidence of split- minimum values listed in Table 6.Nonperforated pipe samples ting, cracking, or breaking when pipe is tested in accordance shall be placed so that the minimum wall thickness is upper- with 11.3. most (adjacent to the top bearing plate). Perforated pipe 8.2.4 Solvent Cement Joint Tightness (Referee Test)—The samples shall be placed with the marking uppermost(see Table solvent-cement-type joints of nonperforated pipe shall not leak 5). when tested in accordance with 11.4. 11.2 Impact Resistance—Five specimens, each 6 ± 'As in. 8.2.5 Extrusion Quality—The pipe shall not flake or disin- (150 ± 2 mm) long, shall be tested in accordance with Test tegrate when tested for 20 min in accordance with Test Method Method D 2444,using a 20-lb(9.1-kg)Tup B,and the flat plate D 2152. (Holder B). When testing is performed in an environment where temperatures are above 0°C, no more than 15 s shall 9. Retest and Rejection elapse from the time of removal of the specimen from the 9.1 If the results of any test(s) do not meet the requirements conditioning bath until completion of that test. Perforated of this specification, the test(s) may be conducted again in specimens must be positioned with the print marking upper- accordance with an agreement between the purchaser and the most, as shown in Table 5; other specimens may be positioned seller. There shall be no agreement to lower the minimum with a random surface uppermost. All specimens shall be requirement of the specification by such means as omitting located so that the contact point is centered under the tup.All tests that are a part of the specification, substituting or five specimens shall pass. If one specimen fails, another five modifying a test method, or by changing the specification specimens shall be tested; nine out of ten specimens passing limits. In retesting, the product requirements of this specifica- shall be acceptable. tion shall be met, and the test methods designated in the 11.3 Pipe Flattening—Flatten three specimens of pipe each specification shall be followed. If, upon retest, failure occurs, 6 ± 'As in. (150 ± 2 mm) long, between parallel plates in a the quantity of product represented by the test(s) does not meet suitable press until the distance between the plates is twice the the requirements of this specification. wall thickness plus 5% of the nominal diameter of the pipe. The rate of loading shall be uniform and such that the 10. Conditioning compression is completed within 2 to 5 min. Remove the load 10.1 Referee Testing—When conditioning is required for and examine the specimens. There shall be no evidence of tests, the specimens shall be conditioned in accordance with splitting, cracking, or breaking. Procedure A in Practice D 618 at 23 ± 2°C and 50 ± 5% 11.4 Solvent Cement Joint Tightness, Referee Test—A sec- relative humidity for not less than 40 h prior to test.The impact tion of unperforated pipe shall be cemented to a bell or specimens and the surrounding conditioning medium are to be coupling, using the manufacturer's recommendations or, in in thermal equilibrium with one another at a temperature of 0 their absence, the methods described in Practice D 2855. to 1.6°C.Tests shall be conducted under the same conditions of Unless otherwise specified, the assembly shall be allowed to temperature and humidity, unless otherwise specified. stand for at least 6 h. It shall then be subjected to an internal 10.2 Quality Control: pressure of at least 25 psi (170 kPa) using water as the test medium. The pressure shall be maintained for at least 1 h. There shall be no leakage. Elastomeric seal joints shall TABLE 7 Impact Strength at 0°C conform with Specification D 3212. Nominal J ft lbf Pipe Type Type Type Type 12. Certification Size,in. PS 28 PS 46 PS 28 PS 46 12.1 When specified in the purchase order or contract, a 4 75 88 55 65 producer's or supplier's certification shall be furnished to the s ss s5 85 129 purchaser that the material was manufactured,sampled,tested, 8 toz izs �s ss P p and inspected in accordance with this specification and has 4 Convrinht by ASTM Tnt'l tall riohtc r•canicAl• F 758—95 (2000) been found to meet the requirements. When specified in the 13.3 Marking on perforated pipe shall be placed as shown purchase order or contract, a report of the test results shall be on the diagram inTable 5. furnished. 13.4 All bends and fabricated fittings shall be marked as follows: 13. Marking 13.4.1 Manufacturer's name or trademark, 13.1 Quality of Marking—The marking shall be applied to 13.4.2 Nominal size, the pipe in such a manner that it remains legible (easily read) 13.4.3 Material designation (PVC), after installation and inspection. 13.4.4 This designation "ASTM F 758", and 13.2 All pipe shall be clearly marked at intervals of no more 13.4.5 Bends shall also be marked to show the degree and than 5 ft(1.5 m)with 3/a-in. (9-mm) or larger letters as follows: radius of curvature, that is, 90° 24 in. R. g 13.2.1 Manufacturer's name or trademark, 13.2.2 Nominal pipe size, 13.2.3 Material designation (cell classification), 14. Quality Assurance 13.2.4 Optional:The words "HIGHWAY UNDERDRAIN", 14.1 When the product is marked with this designation, 13.2.5 "Type PS 28" or "Type PS 46", F 758,the manufacturer affirms that the product was manufac- 13.2.6 This designation, "ASTM F 758", and tured, inspected, sampled, and tested in accordance with this 13.2.7 Date of manufacture, plant designation, and other specification and has been found to meet the requirements of control symbols are internally required by the manufacturer. this specification. SUPPLEMENTARY REQUIREMENTS GOVERNMENT/MILITARY PROCUREMENT These requirements apply only to federal/military procurements, not domestic sales or transfers. Si. Responsibility for Inspection—Unless otherwise sped- S.2.1 Packaging—Unless otherwise specified in the con- fled in the contract or purchase order, the producer is respon- tract, the material shall be packaged in accordance with the sible for the performance of all inspection and test require- supplier's standard practice in a manner ensuring arrival at ments specified herein. The producer may use his own or any destination in satisfactory condition and which will be accept- other suitable facilities for the performance of the inspection able to the carrier at lowest rates.Containers and packing shall and test requirements specified herein, unless disapproved by comply with Uniform Freight Classification rules or National the purchaser. The purchaser shall have the right to perform Motor Freight Classification rules. any of the inspections and tests set forth in this specification S.2.2 Marking—Marking for shipment shall be in accor- where such inspections are deemed necessary to ensure that dance with Fed.Std.No. 123 for civil agencies and MIL-STD- material conforms to prescribed requirements. 129 for military agencies. NOTE S1.1-S.1.1 In U.S.federal contracts,the contractor is respon- sible for inspection. NOTE S2.1--- The inclusion of U.S. Government procurement re- S2. Packaging and Marking for U. S. Government Procure- quirements should not be construed as an indication that the U.S. ment: Government uses or endorses the products described in this specification. 5 Convrieht by ASTM Int'l(all rights recervedL • F 758-95 (2000) ANNEX (Mandatory Information) Al. TYPICAL MOLDED FITTINGS 5111,, - a I t Couplings Nominal Size,inA. Tees Nominal Size,in. Wyes Nominal Size,in. Reducers Nominal Size,in. 4 4 4 4 x 6 6 6 6 6 x 8 8 8 8 ARequirements and dimensions of these and other fittings are described in Specification D 3034. ASTM international takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.Users of this standard are expressly advised that determination of the validity of any such patent rights,and the risk of infringement of such rights,are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised,either reapproved or withdrawn.Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters.Your comments will receive careful consideration at a meeting of the responsible technical committee,which you may attend.if you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards,at the address shown below. This standard is copyrighted by ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959, United States. Individual reprints(single or multiple copies)of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585 (phone), 610-832-9555 (fax), or service @astm.org (e-mail); or through the ASTM website (www.astm.org). 6 ConvriQht by ASTM Tnt'l tall riohts recerveAl• AVAILABLE IN 24"OR 30" AVAILABLE IN a CONCENTRIC CONE ILLUSTRATED 24",30'*36" ° 24"*30"OPENINGS AVAILABLE 36" a a PROFILE GASKETS AT ALL JOINTS I' a a AVAILABLE IN TYPICAL LIFTING INSERTS IN 1',2',3'OR 4' e ALL RISER SECTIONS AND CONES �z as 0-RING GASKETS AT ALL 4' JOINTS e J°d TYPICAL LIFTING INSERTS r„,/IN ALL 4'I.D. BASE SECTIONS 24" 1"DROP PER FT. Z °I a ° 6"1 FLATTOP ILLUSTRATION a° a ° a �" FOR SHALLOW MANHOLE A 5" 24" 0 0 48" a - (am) - Sg v 12" 1111:111 - a 48" MANHOLE - EXTENDED BASE . WITH REDUCING CONE a I"DR FT. OP PER I • LI 3"X8"W3XW2.5 WELDED WIRE IN ALL SURFACES*BOTTOM 58" - GENERAL NOTES: #3 BAR 12"O.C. WITH EACH WAY - WATER TIGHT GASKETS AT ALL PIPE CONNECTIONS - HOLES AS SPECIFIED - MAX. DIA. = 28" DIA. 1 1049 highway 287 - AVG. WEIGHT OF 2' DEEP BASE W/8" The Turner Company Rhome,Tx 76075 INVERT = 5000# - RISER WEIGHT = 800#/VT.F (817)638-9053 - MANUFACTURED TO YOUR SPECIFICATIONS Product: - INVERT DEPTH SHALL SE EQUAL TO THE 48" I.D. MANHOLE - EXTENDED BASE LARGEST PIPE DIAMETER concrete: 4,500 PSI MIN. - 28 DAY STRENGTH Reinforcement: MEETS OR EXCEEDS ASTM-C-478-95 REQUIREMENT Size: Date: DWG No. Weight: Cretex •Specialty Products d 1 \ J Internal rubber sleeve developed to stop inflow under the manhole frame. RUBBER SLEEVE Available in STANDARD 8-3/8",WIDE 10",and EXTRA-WIDE 13"sleeves are made of rubber which conforms to the physical requirements of ASTM C-923, as TOOL SLOTS modified,with a minimum 3/16 inch thickness for durability and resistance to puncturing or tearing.The STANDARD sleeve is double pleated,the WIDE sleeve is triple pleated,and the p IIIIN'„Sillll EXTRA-WIDE is quadruple pleated to provide for a minimum LOOKING��--- 2 inch vertical or horizontal movement before stretching the i.. TABS TAB material. Flexibility of this material allows one size to fit a 0 , - sLOts frame/chimney diameter range of more than 20%. '41 , //- ;1`•� U.S.Patent ry / 1 *5,496,128 EXTENSION The 7"and 10"wide rubber extensions are /- I made from the same material and have the same minimum j/TENSION RUBBER� thickness as the sleeve.The top portion fits into the sleeve's EXPANSION SLEEVE lower band recess,under the lower band. BAND -• U.S.Patent#5,496,128 EXPANSION BANDS The one piece channeled expansion bands are 1-3/4 inches wide and are fabricated from high quality, corrosion resistant, 16 gauge stainless steel conforming to the requirements of ASTM A-240 Type 304.The multiple transverse tab slots in the band provides for ADVANTAGES. 2-12 inches of diameter range.An easy to use mechanical expansion tool quickly expands the band to compress the rubber sleeve against the manhole frame and chimney.Once expanded,the band is locked in place by the engagement *Provides watertightness,while having the flexibility to r of the locking tabs in the proper slots, providing a flexible allow the manhole frame to move with the surrounding r watertight seal. pavement as it reacts to the forces of frost heave, - thermal expansion/contraction and traffic loadings. *Reduces excess clearwater in sanitary sewer system by stopping manhole frame/chimney inflow, thereby fi providing more system capacity and reducing treatment and pumping costs. *Installed in the inside of existing manholes, no x; expensive time-consuming excavating and pavement replacement is needed. CRETEX SPECIALTY PRODUCTS I *Installed in new manholes after paving is complete without interfering with or delaying paving operations. 1 r Tt Reusable — can be moved or removed and reused ' elsewhere if needed. LIFE F S DESIGN ®Constructed of high quality,long-lasting materials. i; GENERAL INSTALLATION This section includes the materials and procedures required for the The contractor shall field measure the manhole to determine the internal sealing of the frame-chimney joint area of brick and block information required on the manufacturer's"Sizing and Ordering" manholes and the entire chimney area of precast,fiberglass and procedure.This information is needed to obtain the proper size of plastic manholes. the bands,the size and shape of the rubber sleeve and the need for and size of any extensions. FRAME SEAL The surfaces against which the sleeve and extension are to be Frame seals shall be designed to prevent leakage of water through compressed shall be circular,clean,reasonably smooth and free the above described portions of the manhole throughout a 50 year of any loose material and excessive voids.If the masonry surface design life.The seal shall remain flexible throughout this design life, is rough, sloped, or irregular and would not provide an effective allowing repeated vertical movements of the frame of not less than seal,an approved non shrink patching mortar shall be used to 2 inches and/or repeated horizontal movement of not less than 1/2 prepare a uniformly vertical surface for the bottom of the sleeve inch,at rates greater than 1/10 inch per minute. and extension to seal against.Any flaws in the manhole frame such as cracks,pits of protrusions,shall be repaired by either filling with Frame seals shall consist of a flexible internal rubber sleeve, mortar or grinding smooth. extensions,and stainless steel expansion bands,all conforming to After the rubber sleeve and extension,where needed,has been the following requirements: placed in the proper position,the stainless steel expansion bands 1. RUBBER SLEEVE AND EXTENSION - The flexible shall be installed in the band recesses and individually expanded rubber sleeve,extensions and wedge strips shall be extruded as required to provide a watertight seal. or molded from a high grade rubber compound conforming to Installation shall be in accordance with the manufacturer's the applicable requirements of ASTM C-923,with a minimum 1500 psi tensile strength,maximum 18%compression set and instructions. a hardness(durometer)of 48+5. The sleeve shall be either double,triple,quadrupled pleated with a minimum unexpanded vertical height of 8 inches, 10 PHYSICAL PROPERTIES inches,and 13 inches respectively and a minimum thickness of 316 inches.The top and boffom section of the sleeve shall Tensile Strength 1500 psi contain an integrally formed expansion band recess and multiple sealing fins. Elongation at break 350%min The top section of the extension shall have a minimum Hardness(Durometer) 48±5 thickness of 332 inches and shall be shaped to fit into the boffom band recess of the sleeve under the bottom chimney Accelerated oven-aging max. 15%decrease of seal band.The remainder of the extension shall have a minimum tensile,20%of elongation thickness of 316 inches.The bottom section of the extension Chemical resistance no weight loss in 1 N of shall contain an integrally formed expansion band recess and sulfuric or hydrochloric acid. multiple sealing fins matching that of the rubber sleeve. Any splice used to fabricate the sleeve and extension shall be Compression set 18% max.decrease hot vulcanized and have a strength such that the sleeve shall Water absorption max 10% increase by weight withstand a 180 degree bend with no visible separation. 2. EXPANSION BANDS -The expansion bands used to Ozone resistance Rating 0 compress the sleeve against the manhole shall be 16 gauge Low temperature stainless steel conforming to ASTM A-240,Type 304, with a brittle point No fracture at-40 C° minimum with of 1-3/4 inches. The bands shall have a minimum adjustment range of 2-1/2 Tear resistance 2001b.f/in. • diameter inches and the mechanism used to expand the band Splice strength 108°bend with no visible shall have the capacity to develop the pressures necessary to separation make a watertight seal.The band shall be permanently held in this expanded position with a positive locking mechanism,any studs and nuts used for this mechanism shall be stainless steel conforming to ASTM F-923 and 594,Type 304. Cret x Specialty Products j �y* ' SIZING AND ORDERING PROCEDURE MEASUREMENTS SEAL SIZES FRAME—Measure the inside diameter of the frame at its base The rubber sleeves and extensions are normally available in 20,22, D1,and note the height of the flat surface and if this surface is 24,26,28,30 and 36 inch diameters.The steel expansion bands straight or tapered. are available in the same sizes and increments,with each having a 1. The width of the sealing surface must beat least 2-1/2". 2-1/2"diameter range that extends from approximately 1"smaller 2. If the inside surface is tapered,measure and note the frame's to 1-1/2"larger than the stated size.Sizes of sleeves,extensions and diameter at a point 3"up from its base. bands other than these are available by special order. 3. The frame can not be offset from the chimney or cone/corbel ®ERINO by more than approximately 3 inches. SLEEVE AND EXTENSION DIAMETER — Order the sleeve CHIMNEY—Measure the inside diameter Cl,and height H1 and extension the even size closest to the smaller of either the of the chimney. frame diameter D1 or the applicable chimney or cone/corbel diameter Cl or C2. T. The inside diameter of the chimney C1 must be within a BAND DIAMETERS — Order the bands the same size as the maximum of 20 percent of the inside diameter of the frame D1.If sleeve if the diameters of both sealing surfaces, Dl and Cl or mortar is to be used on the chimney to provide a sealing surface C2 are within the band's diameter range;if however,one of these or to bring it within this tolerance,estimate what the diameter will surface diameters is larger than the band's range,order the next be after mortaring, larger band for sealing against that surface. 2. A minimum 2-1/2" high vertical sealing surface must be SLEEVE SHAPE—Order either a"Straight", "T-1","T-2" or "T- provided on either the chimney,the cone/corbel,or both. 3" sleeve as required to fit the manhole configuration.If necessary, CONE/CORBEL — If the chimney height H1 is less than also order one of the"Wedge Inserts".Refer to the"Cross Sections approximately 2-1/2 inches,or if an extension is to be used,measure and Usage"sheet for details. the inside diameter C2 and height of the straight section H2 of the EXTENSION HEIGHT — Order the height of extension or cone/corbel.See installation instructions if H2=0. extensions necessary to span from the frame to the precast cone. ORDERING AND REPORT FORM Community: Manhole No: Location: Date: Describe any pertinent factors: Tapered p' Frame • Straight (see above)j • Frame D, = in. • ii i 4 hill SLEEVE:Dia. Width Shape Wedge = in. L-1 C, = in. EXTENSION:Diameter 7" 10" Band BAND DIAMETER:Top Boffom H = in. f ( C, = in. � � Cretex Specialty Products _ _ x INTERNAL N= T :LL TI ON INSTRUCTIONS SURFACE PREPARATION _ All loose and protruding 4. Lubricate the second band and install it in the other band recess, mortar and brick that would interfere with the seal's performance attach the tool and expand as before,keeping the bands parallel. shall be removed and the appropriate surfaces of the frame,chimney The bands can be put closer together if only a limited height is and/or cone/corbel prepared in accordance with the manufacturer's available or if excessive sleeve expansion is desired. instructions. 5. If an extension is being used,position it such that the top portion INSTALLATION - See the"Installation Variations"and"Cross of the extension fits snugly into the lower band recess of the Section and Usage" sheets for various installation options. Read chimney seal sleeve,prior to installing the band. Lubricate and complete instructions before starting installation. install the band inside the recess formed by the top portion of the 1. Install the rubber sleeve with the printing at the top and the top extension and expand as before,thereby compressing both the edge lined up with the previously applied alignment marks. extension and the sleeve against the manhole surface. 2. Wipe off the outside of one stainless steel band and apply a 6. If multiple extensions are required,repeat step 5. moderate coating of band lubricant to the slot area and a light to 7. Position the extension's bottom sealing surface on the vertical moderate coating to the remainder of the band's outside surface. surface of the cone. Lubricate and install the third band in the Either the top band or the smaller band, if two different sized lower band recess of the extension and expand as before. bands are being used,is to be installed first. 8. Check the top and boffom edges of the installed sleeve to insure 3. Install the band in the appropriate band recess with the slotted that they have been properly compressed against the surfaces. end against the rubber surface.Position the expansion tool as shown below and expand the band until the locking tabs pop NOTE:ALWAYS WEAR GLOVES WHEN HANDLING BANDS into the tightest slots possible. Loosen the tool slowly until the tabs are fully engaged in the slots,then continue to loosen and remove the tool.When installing a larger diameter band,use one of the auxiliary tool slots to start the expansion process.Move one leg of the tool to the primary tool slot if necessary to complete expansion. Locking _ ��Primary Tool Slot Auxiliary Fool Slots .Ii?Uftt otched 1111000..€ ttt8 Notched �iT►ialt End of Tool End of Tool tits into fits into Primary Tab End 15/16° Nut Tool Slot Tool Slot EXPANSION TOOL i ® O CRETEX SPECIALTY PRODUCTS N16 W23390 Stoneridge Dr-A,Waukesha,WI 53188 262-542-8153 • Fax 262-542-0301 • 800-345-3764 • www.cretexseals.com STORM DRAIN: • PIPE AND FITTINGS o CHARLOTTE PIPE—SCH40 PIPE o CANTEX—SCH40 CONDUIT PIPE • CASTINGS o BASS & HAYS-400 Series RING &COVER, CURB INLET CHARLO PIPE AND FOUNDRY COMPANY Suggested Specification System: PVC Schedule 40 Pressure Pipe and Fitting System Scope: This specification covers PVC Schedule 40 pipe and fittings for pressure applications. This system is intended for pressure applications where the operating temperature will not exceed 140°F. Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a Cell Class of 12454 as identified in ASTM D 1784. PVC Schedule 40 pipe shall be Iron Pipe Size (IPS) conforming to ASTM D 1785. PVC Schedule 40 fittings shall conform to ASTM D 2466. Pipe and fittings shall be manufactured as a system and be the product of one manufacturer. All pipe and fittings shall be manufactured in the United States. Pipe and fittings shall conform to National Sanitation Foundation (NSF) Standard 61 or the health effects portion of NSF Standard 14. Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall conform to all local plumbing, building, and fire code requirements. Buried pipe shall be installed in accordance with ASTM F 1668. Solvent cement joints shall be made in a two step process with primer manufactured for thermoplastic piping systems and solvent cement conforming to ASTM D 2564. The system shall be protected from chemical agents, fire stopping materials, thread sealant, plasticized vinyl products, or other aggressive chemical agents not compatible with PVC compounds. Systems shall be hydrostatically tested after installation. Testing with compressed air or gas is not recommended. Testing with compressed air or gas may result in injury or death. Referenced Standards: ASTM D 1784 Rigid Vinyl Compounds ASTM D 1785 PVC Plastic Pipe, Schedule 40 ASTM D 2466 PVC Plastic Fittings, Schedule 40 ASTM D 2564 Solvent Cements for PVC Pipe and Fittings ASTM F 1668 Procedures for Buried Plastic Pipe NSF Standard 14 Plastic Piping Components and Related Materials NSF Standard 61 Drinking Water System Components - Health Effects Note: Latest revision of each standard applies. (908) PO Box 35430 Charlotte,NC 28235 USA 704/372-5030 800/438-6091 FAX 800/553-1605 www.charlottepipe.com C T ._ . : Schedule 40 Conduit - Bell End Meets specifications UL 651 and NEMA TC 2 Rated for 90°C Cable Sunlight Resistant 10'Lengths (1•3 .Y- r;: Flo- '�;'E a -''t --z.,...,,,, Schedule 40 Conduit �, : '' Belled End 10'Lengths , f�� mss_ �` } � � .� Part No. Size O.D. I.D. Min.Wall Bell Depth Approx. Feet per Wt/Ft Pack A52AE12 1/2 .840 .622 .109 1.750 .162 6,000 A52AE12H 1/2 .840 .622 .109 1.750 .162 3,000 A52AG12 3/4 1.050 .824 .113 2.000 .216 4,400 A52AG12H 3/4 1.050 .824 .113 2.000 .216 2,200 A52BA12 1 1.315 1.049 .133 2.250 .320 3,600 A52BA12H 1 1.315 1.049 .133 2.250 .320 1,800 A52BC12 1-1/4 1.660 1.380 .140 2.500 .434 3,300 A52BC12H 1-1/4 1.660 1.380 .140 2.500 .434 1,650 A52BE12 1 1/2 1.900 1.610 .145 2.750 .520 2,250 A52BE12H 1-1/2 1.900 1.610 .145 2.750 .520 1,130 A52CA12 2 2.375 2.067 .154 3.250 .699 1,400 A52CE12 2-1/2 2.875 2.469 .203 3.500 1.108 930 A52DA12 3 3.500 3.068 .216 4.000 1.450 880 A52DE12 3-1/2 4.000 3.548 .226 4.250 1.744 630 A52EA12 4 4.500 4.026 .237 4.750 2.067 570 A52FA12 5 5.563 5.047 .258 5.750 2.801 380 A52GA12 6 6.625 6.065 .280 6.325 3.636 260 A52JA12 *8 8.652 7.981 .322 6.500 5.474 180 * Non UL Note: 20'length available one request Schedule 40 conduit complies with federal and military specifications by conforming to UL 651. CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com CANT " x Schedule 80 Conduit - Bell End Meets specifications UL 651 and NEMA TC 2 Rated for 90°C Cable Sunlight Resistant 10'Lengths 0 Schedule 80 Conduit Belled End 10'Lengths b ,,',," Part No. Size O.D. I.D. Min.Wall Bell Depth Approx. Feet per Wt/Ft Pack A53AE12 1/2 .840 .546 .147 1.750 .206 6,000 A53AE12H 1/2 .840 .546 .147 1.750 .206 3,000 A53AG12 3/4 1.050 .742 .154 2.000 .280 4,400 A53AG12H 3/4 1.050 .742 .154 2.000 .280 2,200 A53BA12 1 1.315 .957 .179 2.250 .412 3,600 A53BA12H 1 1.315 .957 .179 2.250 .412 1,800 A53BC12 1-1/4 1.660 1.278 .191 2.500 .571 3,300 A53BC12H 1-1/4 1.660 1.278 .191 2.500 .571 1,650 A53BE12 1-1/2 1.900 1.500 .200 2.750 .692 2,250 A53BE12H 1-1/2 1.900 1.500 .200 2.750 .692 1,130 A53CA12 2 2.375 1.939 .218 3.250 .959 1,400 A53CE12 2-1/2 2.875 2.323 .276 3.500 1.463 930 A53DA12 3 3.500 2.900 .300 4.000 1.959 880 A53EA12 4 4.500 3.826 .337 4.750 2.863 570 A53FA12 5 5.563 4.813 .375 5.750 3.975 380 A53GA12 6 6.625 5.761 .432 6.325 5.464 260 Note: 20'length available on request CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com / T= - Forte-Duct® Cellular Core Conduit & Duct x sue, , && a 7= 3 F Z ' v Schedule 40 Forte-Duct® Conduit 20'Lengths . Meets UL 651 Specifications MIN. APPROX. FEET PART NO 2 2.375 2.067 . SIZE O.D. I.& WALL WT/FT' PER PACK A60CA42* .154 .512 2800 A60CE42* 2-1/2 2.875 2.469 2.03 .810 1860 A60DA42 3 3.500 3.068 .216 1.050 1760 A60EA42 4 4.500 4.026 .237 1.460 1140 .258 A60FA42 5 5.563 5.047 1.901 760 A60GA42 6 6.625 6.065 .280 2.470 520 RUS Listed DB-120 Forte-Duct® Duct 20'Lengths Not UL Listed MIN. APPROX. FEET PART NO, SIZE O.D. I.D. WALL WT/FT PER PACK A59DA42 3 3.500 3.240 .130 .656 1760 A59EA42 4 .167 1.068 1140 A59FA42 5 5.563 4.500 5.154.166 1 .206 1.636 760 A59GA42 6 6.625 6.135 .245 2.360 520 CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com i NTmit Utility Duct TC6 Bell End - 500,000 psi modulus Type EB20 complies with federal and military specifications by conforming to UL 651A. Conforms to NEMA TC6 and ASTM F-512 Rated for 90°C Cable 20'Lengths Bell End Type DBHM-60 (For Direct Burial) Part No. Size O.D. I.D. Mm.Wall Bell Depth Approx. Feet per Wt/Ft Pack A79CA42 2 2.375 2.255 .060 3.250 .337 2,800 A79DA42 3 3.500 3.316 .092 4.000 .734 1,760 A79EA42 4 4.500 4.258 .121 4.750 1.218 1,140 A79FA42 5 5.563 5.259 .152 5.750 1.846 760 A79GA42 6 6.625 6.261 .182 6.325 2.634 520 Type EBHM-20 (For Encasement Burial) Part No. Size O.D. I.D. Min.Wall Bell Depth Approx. Feet per Wt/Ft Pack A77CA42 2 2.375 2.255 .060 3.250 .337 2,800 A77DA42 3 3.500 3.378 .061 4.000 .547 1,760 A77EA42 4 4.500 4.336 .082 4.750 .901 1,140 A77FA42 5 5.563 5.357 .103 5.750 1.397 760 A77GA42 6 6.625 6.375 .125 6.325 1.969 520 Utility Duct ASTM F-512 Bell End - 500,000 psi modulus Conforms to ASTM F-512 Rated for 90°C Cable 20'Lengths-Bell End Type DB-100 HM (For Direct Burial) Approx. Feet per Part No. Size O.D. I.D. Min. Wall Bell Depth Wt/Ft Pack A72DA42 3 3.500 3.276 .112 4.000 .853 1,760 A72EA42 4 4.500 4.210 .145 4.750 1.419 1,140 A72FA42 5 5.553 5.205 .179 5.750 2.165 760 A72GA42 6 6.625 6.199 .213 6.325 3.070 520 CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com JIT Utility Duct TC8 Bell End - 400,000 psi modulus Conforms to NEMA TC8 and ASTM F-512 Rated for 90°C Cable 20'Lengths Type DB-120 (For Direct Burial) Part No. Size O.D.` I.D. :' Min.Wall Bell Depth Approx. Feet per Wt/Ft Pack< A54CA42 2 2.375 2.221 .083 3.250 .427 2,800 A54DA42 3 3.500 3.264 .127 4.000 .910 1,760 A54EA42 4 4.500 4.192 .166 4.750 1.502 1,140 A54FA42 5 5.563 5.181 .205 5.750 2.325 760 A54GA42 6 6.625 6.171 .244 6.325 3.316 520 Type EB-35 (For Encasement Burial) Part No, Size O.D. LD. Min. Wall Bell Depth Approx. Feet per Wt/Ft Pack A56CA42 2 2.375 2.255 .060 3.250 .337 2,800 A56DA42 3 3.500 3.348 .082 4.000 .584 1,760 A56EA42 4 4.500 4.300 .109 4.750 1.017 1,140 A56FA42 5 5.563 5.311 .136 5.750 1.586 760 A56GA42 6 6.625 6.321 .164 6.325 2.210 520 Note: 400,000 psi modulus duct is non-stocking CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com I ;,ANTM11 . Utility Duct TC8 Bell End - 500,000 psi modulus Conforms to NEMA TC8 and ASTM F-512 Rated for 90°C Cable 20'Lengths Type DBHM-120 (For Direct Burial) Part No. Size O.D. I.D. Mina Wall Bell Depth Approx. Feet per Wt/Ft- Pack A55BA42 1 1.315 1.195 .060 2.250 .169 7,200 A55BE42 1-1/2 1.900 1.780 .060 2.750 .247 4,500 A55CA42 2 2.375 2.221 .077 3.250 .427 2,800 A55DA42 3 3.500 3.264 .118 4.000 .910 1,760 A55EA42 4 4.500 4.192 .154 4.750 1.502 1,140 A55FA42 5 5.563 5.181 .191 5.750 2.325 760 A55GA42 6 6.625 6.171 .227 6.325 3.316 520 Type EB-35HM (For Encasement Burial) Part No. Size O.D. I.D. Min.Wall Bell Depth Approx. Feet per Wt/Ft Pack A57CA42 2 2.375 2.255 .060 3.250 .337 2,800 A57DA42 3 3.500 3.348 .076 4.000 .584 1,760 A57EA42 4 4.500 4.300 .100 4.750 1.017 1,140 A57FA42 5 5.563 5.311 .126 5.750 1.586 760 A57GA42 6 6.625 6.321 .152 6.325 2.210 520 CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com CAkIRITME,,. Telephone Duct Fittings Coupling End Bells Carton Carton Part No. Description Part No. Description QtY. 6161632 4"Center Stop 50 5164015 4"x 6"End Bell 50 6161552 4"No Center Stop 50 5164017 4"x 20"End Bell 30 Poly Plug Adapters Part No. Description Carton Carton Qty. Part No. Description.. Qty 5315262 4"Poly Plug w/Pulling Eye 80 5163550 4"Bell 4.5 to Bell 4.25 50 5163551 4"Spigot 4.5 to Bell 4.25 50 5°Angle Coupling 5136552 4"Bell 4.5 to Spigot 4.25 50 Part No. Description Carton Qty. Base Spacers 6161642 4"5°Angle Cplg (B x S) 50 Part No. Description Carton Qty Stopper(Expansion Plug) 5335971 4"x 1"Base 175 Part No. Description Carton 5335968 4"x 1-1/2"Base 140 Qty. 5335967 4" x 2"Base 140 304C04B 4" ST-402 Stopper 50 5335969 4"x 3"Base 120 Cement (#99) Intermediate Spacers Carton Part No. Description Carton Qty. Part No. Description 7210601 PVC Cement- 1/2 Pint 24 QtY. 7210602 PVC Cement-Pint 12 5336017 4"x 1"Intermediate 200 7210603 PVC Cement- Quart 12 5336021 4"x 1-1/2"Intermediate 150 7210605 PVC Cement-Gallon 6 5336019 4" x 2"Intermediate 125 5336024 4"x 3"Intermediate 90 4" CAO Telephone Duct Sweeps Belled End Radius Degree 2' 3' 4' 5' 6' 9' 12' 90 5163856 5163850 5163859 5163853 5163847 5163857 5163855 45 5163748 5163750 5163753 5163763 5163751 5163752 5163758 30 5163879 5163742 5163740 5163741 5163635 5163881 5163743 22-1/2 5163638 5163630 5163631 5163627 -- -- 5163643 11-1/4 5163616 5163620 5163615 -- -- -- -- CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com ICAPIT-Mt, General Telephone Duct GTS-8342 Telephone Duct Belled End 20'Lengths Part No. Size O.D. LD Min. Bell Approx. Feet per Wall Depth Wt/Ft Pack A 11 CA42 2"GT 42 2.375 4.154 .077 4.750 .410 2,800 Al2EA42 4"GT-42 4.500 4.036 .145 4.750 1.550 1,140 Schedule 40 Conduit Belled End 10'Lengths Part No. Size O.D. I.D. Min. Bell Approx. Feet per Wall Depth Wt/Ft Pack A52CA12 2 Schedule 40 2.375 2.067 .154 3.250 . .699 1,400 A52EA12 4 Schedule 40 4.500 4.026 .237 4.750 2.067 570 Schedule 80 Conduit Belled End 10'Lengths L Part No. Size O.D. LD. Min. Bell Approx. Feet per Wall Depth Wt/Ft Pack A53CA12 2 Schedule 80 2.375 1.939 .218 3.250 .959 1,400 A53EA12 4 Schedule 80 4.500 3.826 .337 4.750 2.863 570 Schedule 40 and 80 are available in 1/2"thru 6"upon request CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com CAINITMC GTS-8342 Telephone Fittings Conforms to GTS-8342 Specifications Swedged Coupling Poly Plug Carton Carton Part No. Description Part No. Description Qt,. 6151660 2"B x B Cplg 20 5315258 2"Poly Plug w/Pulling Eye 70 6151670 4"B x B Cplg 15 5315262 4"Poly Plug w/Pulling Eye 80 Sleeve Coupling Female Adapters Part No, Description Carton Carton Qty, Part No. Description QtY•' 6151650 2"x 8"Slip Cplg 20 5144048 2"Female Adapter 40 6161675 4"x 10"Slip Cplg 9 5144052 4"Female Adapter 20 Split Sleeve Coupling Male Adapters Carton Part No. Description Carton Qty. Part No. Description Qty 6151760 2"GT-8342 Split Cplg 20 5140108 2"Male Adapter 40 6151770 4"GT-8342 Split Cplg 15 5140112 4"Male Adapter 20 6151690 4"Split Cplg w/4.350 ID 50 Adapter Two Piece Expansion Coupling Carton Part No. Description Carton Part No. Description Q . Qty. 5144036 2"Expansion Cplg 25 5163551 4"GTS-8342 to GTS 8343 50 (4.50 Spigot to 4.35 Bell) 5144040 4"Expansion Cplg 6 One Piece Expansion Coupling Part No. Description Carton Spacers QtY• 5144019 2"Expansion Cplg 25 Carton p p g Part NNo. Description 5144023 4"Expansion Cplg 5 QtY._, 5°Angle Coupling 5335961 2"x 1-1/2" Base 250 5335968 4"x 1-1/2" Base 140 Carton 5336000 2"x 1-1/2" Intermediate 350 Part No. Description QtY. 5336021 4"x 1-1/2" Intermediate 150 6151680 4"5°Angle Cplg (B x S) 15 Reducer Part No Description Carton Cement (#99) QtY• 5163552 4"Bell 4.50 to Spigot 4.35 50 Part No Description Carton Qty End Bells 7210601 PVC Cement- 1/2 Pint 24 Carton 7210602 PVC Cement-Pint 12 Part No Description Qty, 7210603 PVC Cement-Quart 12 5144102 2"End Bell 40 7210605 PVC Cement-Gallon 6 5144106 4"End Bell 50 CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com T GTS-8342 Telephone Fittings Conforms to GTS-8342 Specifications 2" GTS-8342 Sweeps -Belled One End Degree egree 24" 36" 48" 150" 90 5301141 5301142 5301143 5301144 45 5301131 5301132 5301133 5301135 30 5301121 5301122 5301123 5301125 22-1/2 5301111 5301112 5301113 5301115 11-1/4 5301101 -- -- 5301105 Other sizes available upon request 4" GTS-8342 Sweeps -Belled One End Degree Radius 24" 36" 48" 60" 1.50" 90 5301190 5301191 5301192 5301193 5301205 45 5301180 5301181 5301182 5301183 5301185 30 5301170 5301171 5301172 5301173 5301175 22-1/2 5301160 5301161 5301162 5301163 5301165 11-1/4 5301150 5301151 5301152 5301153 5301155 Other sizes available upon request GT Riser Bends-Bell One End Description Radius 24" 36" 48" 2"Schedule 40 5253955 5253956 -- 4"Schedule 40 -- 5253965 5253966 2"Schedule 80 5302101 5302102 -- 4"Schedule 80 -- 5302111 5302112 Other sizes available upon request CANTEX INC. 301 Commerce Ste.2700 Fort Worth,Texas 76102 817-215-7000 Fax: 817-215-7001 www.cantexinc.com } �4*{4 it : : _ 0 4 3°'i'''Cn n -� / ) 2 1 111t1, A71-4` rpori' to .raver C 4 ,, AWE m_, _ l car cri p = 2- rn J7( W r , 2 a L PM 59, MI \ 03 'Z 05,05 -n 01 0 Q 0 0 ve x tl7r- ,-- m < › 4- vt co ttn c --I �� !MI rest Fri Iii ,,m, ir,_ to m a - 1 100 O 3 co