Loading...
DR1201-LR130708 JUL-17-2013 01:49 P.07/14 Texas CMT, Inc. Construction Materials Testing GEE Consultants, Inc. and Environmental Consulting 10044Monroe Drive • Dallas, Texas 75229 • (214) 352-6957 • Fax (214) 352-6972 • www .texascmt.com • REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOIL Density Report No.6 (213-0134) Method:ASTM D6938 D698 Page 1 of 1 Client:City of Coppell Material Description Maximum Optimum Dry Density Moisture • Project: Creekview Drive Roadway (Lbs./cu.ft.) Content Improvements 2013 (Percent) 1. Reddish Brown Clay 97.7 22.9 Test Date:July 8,2013 2. Yellowish Brown Clayey Sand 120.9 12.2 (Select Fill) Report Date:July 16,2013 3. Dark Brown Clay 99.5 22.9 4. Brown,Tan and Yellowish 97.9 23.7 Required Density(%):Min.95% Brown Clay • Required Moisture(%):- Clays:OMC+0 to+4%; Sand and/or Select Fill:OMC-3 to+3% • • • Test No. Material Probe Location/Elevation(and/or)Lift In-Place In-Place • Percent No. Depth Dry Density Moisture Compaction (inches) (Lbs/Cu.Ft.) Content(%) (%) 13 2 8 Westbound Lane,Sta. 1+50, 10'N.of 123.1 10.3 101.8 Center Line(C.L.), 1'Lift of Select Fill . 14 2 8 Westbound Lane,Sta.3+00,8'N.of C.L., 120.6 9.9 99.8 1" Lift of Select Fill 15 2 8 Westbound Lane,Sta.2+93,8'N.of C.L., 121.5 9.9 100.5 rd Lift of Select Fill /� 16 2 6 Westbound Lane, Sta.4+25,8'N.of C.L., 112.0 7.4* 92.6*/ 1" Lift of Select Fill 17 2 6 Westbound Lane,Sta.3+75,6'N,of C.L., 117.4 11.9 97,1 Is` Lift of Select Fill 18 2 8 Westbound Lane,Sta.3+70,6'N.of C.L., 123,0 9.3 101.7 2' Lift of Select Fill * Test results did not meet project specifications cc: Mr.Larry Davis-City of Coppell,Phone:972-304-3684;via Fax:972-304-3570 Mr.George Marshall-City of Coppell,Phone:972-304-3562;via E-mail:gMarshall @coppelltx.gov Mr.Rod Lacy-The Fain Group,Phone: 817-927-4388;via E-mail:rlacy @faingp.com Texas CMT,Inc. TBPE Firm: F-4521 Reviewed by: 4 All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of Texas CMT,Inc. The use of our name must receive our prior written approval. Ow letters and reports apply only to the sample tested and/or observed and are not necessarily indicative of the quantities of apparently identical or similar products_