Loading...
ST9902-LR130725<0 R�LIfiIYCE GEOTECFiPlICflL QiOUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Date Sampled: 07/24/2013 Report Date: 07125/2013 Sampled By: Griffiths, Robert Project: West Sandy Lake Road By Order Of: Location: 8in Water Main Order Number: 1770 Client: City of Coppell REPORT: Nuclear Field Density Test LAB NO: 149083 Test Method: See Below TEST RESULTS Report No: Page 1 of 1 Optimum Maximum Proctor Moisture Dry Density Proctor No Date (%) (pcf) Color / Description 148639 -2 07/17/2013 12.0 115.9 Medium Brown Sandy Clay Specification Moisture Band Specification No. Compaction, % Minimum Maximum 1 95 0.0 Location: Test Lift # / No. Depth Location Wet Moisture Dry Percent Density Content Density Proctor Spec. Moisture Proctor Pass (pcf) % (pcf) Number No. Deviation Density Fail 1 0 Station 1 +95 125.5 14.0 110.1 148639 -2 1 +2.0 Gauge No.: 4877 Daily Standard Counts: 07/24/2013 DS: 4007 MS: 515 Test Methods: ASTM D6938 -10 CONFORMS Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kak , CME Department Manager 95.0 Pass THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.