Loading...
Shadowridge P5-CS130801 DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM:th PD-266-SF-9 Shadow Ridge Estates-5 Increment, Lots 1R, 2R & 3R, Block A, a zoning change request from SF-12 (Single Family-12) to PD-266-SF-9 (Planned Development-266-SF-9), to allow the development of three (3) single- family lots on 0.8 acres of property located at the southeast corner of S. Coppell Road and Plantation Drive, at the request of Al Amlani, Baybridge Construction, LLC. STAFF REP.: Matt Steer PROJECT ID# PD-13-0039 DRC DATE: July 27, 2013 and August 1, 2013 CONTACT: Michael Garza, P.E., Civil Engineer, 972-304-7019 COMMENT STATUS: PRELIMINARY FINAL REVISED AFTER P&Z 1. The sewer service will need to be bored to the manhole. 2. The sanitary sewer main extension will need to be an 8” with a manhole on the end. 3. Cleanouts will be required on the property lines. 4. Impact fees will be assessed for 2 of the lots. 5. Show the curb lines/pavement on the plans. 6. The driveway on lot 3R might be in conflict with an existing inlet. 7. There should be an existing sewer service for lot 3R and downstream of the water service. 8. Remove existing driveways on Plantation and build sidewalk. 9. Remove the drainage swale along Plantation. 10. Will the overhead power be buried along Plantation? DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM:th Shadow Ridge Estates-5 Increment, Lots 1R, 2R & 3R, Block A, Replat, th being a replat of Lots 1 and 2 of the Shadow Ridge Estates-5 Increment, to allow the development of three (3) single-family lots on 0.8 acres of property located at the southeast corner of S. Coppell Road and Plantation Drive, at the request of Al Amlani, Baybridge Construction, LLC. STAFF REP.: Matt Steer PROJECT ID# RPR-13-0040 DRC DATE: July 27, 2013 and August 1, 2013 CONTACT: Michael Garza, P.E., Civil Engineer, 972-304-7019 COMMENT STATUS: PRELIMINARY FINAL REVISED AFTER P&Z 1. The sewer service will need to be bored to the manhole. 2. The sanitary sewer main extension will need to be an 8” with a manhole on the end. 3. Cleanouts will be required on the property lines. 4. Impact fees will be assessed for 2 of the lots. 5. Show the curb lines/pavement on the plans. 6. The driveway on lot 3R might be in conflict with an existing inlet. 7. There should be an existing sewer service for lot 3R and downstream of the water service. 8. Remove existing driveways on Plantation and build sidewalk. 9. Remove the drainage swale along Plantation. 10. Will the overhead power be buried along Plantation?