Loading...
DR1201-SP130808Rhonda Adloo From: Sent: To: Subject: Attachments: FYI Sent from my iPhone George Marshall, PE 469- 964 -4731 Begin forwarded message: George Marshall Thursday, August 08, 2013 11:18 AM Larry Davis; Rhonda Adloo; Richard Gee Fwd: Creekview RFI #1 RFI #1 - Acitve Anchor Modification.pdf, ATT00001.htm From: "Ernest Fields" <EFields @walterpmoore.com> To: "George Marshall" <GMarshall @coppelltx.gov> Cc: " mnorth @arkcontractingservices.com11 < m north @arkcontracti ngservices.com >, "Rod Lacy (RLacv @faingp.com)" <RLacv @faingp.com> Subject: Creekview RFI #1 George, I received the attached email requesting a change to our active anchor detail. Ark has asked if we would allow them to use concrete in the unbonded length of the active anchors instead of the non - shrink grout. We have no problem with changing the detail as marked up by Ark. Please let me know if you need anything more formal from me. Thanks, Ernie Ernest L. Fields, P.E., LEED BD +C Principal WALTER P MOORE 1845 Woodall Rodgers Freeway, Suite 1650 Dallas, Texas 75201 -2287 214.740.6200 214.740.6300 fax 214.783.5157 mobile efieldsawalterpmoore.com www.walterpmoore.com THE CONTENTS OF THIS E -MAIL AND ANY ATTACHMENT(S) ARE CONFIDENTIAL AND THE PROPERTY OF WALTER P. MOORE AND ASSOCIATES, INC. 1 Ernest Fields From: Mark North < mnorth@arkcontractingservices.com > Sent: Thursday, August 08, 2013 10:36 AM To: Ernest Fields Cc: rlacy @faingp.com; 'Tiffany Rawls' Subject: Active Anchor Grout RFI Attachments: CREEKVIEW TIEBACK ANCHOR GROUT RFI DETAIL.pdf Ernie, Pursuant to our conversation this morning please find attached the Tieback Anchor Grout RFI Detail for your approval. We would like to install the specified 5000 PSI non shrink grout in the bonded zone of the tieback anchors. The non shrink grout would extend over the end of the 3 inch PVC pipe sleeve 12 inches to seal the unbounded tieback zone. Grease would be installed inside the 3 inch PVC pipe in the unbounded zone as specified. The void between the 10 inch drilled shaft and the 3 inch PVC sleeve would be filled with ready -mix concrete. Please notify us of your approval. If you have any questions please do hesitate to contact me. Thanks, Mark North Ark Contracting Services, LLC 817.478.7400 Office 817.478.7438 Fax 817.475.1355 Cell BFAW BEYOND ANCHOR-N" f-YAR'Eli a- 3` -0. GAMN MKETF REF SECMNS FOR DIMENSION 1 'x6'x6' PLATE ACHORAGE r CAST SWING SURFACE FOR PLATE ANCHC E AND BEAM PWE NON - SHRINK GROUT-- MM ANCHORAGE SYYU To MWAIN 3' MJN CLM COVER . 3" PVC CASING -FILL wml oREASI REF, ROCK ANCHOR NOTES 2 60 Mk DRIM HOLE ANCHOR GROUT, REF. ROCK Al'CHOft NOTES L- Cf?Nl`NDJ5 SiI�El. REINF, BAR WRH-' A4 f? ZERS AT MAX SPACING OF 5`- REF. PUN A�hIO SECTION' FOR qVLENGV, SIDE. AND SIREN • - �� M-1 A L 'Z3L - A TI SCALE: 1/2'= V -Q" ,Y HIGHLY PERMEABLE FILTER FABRIC; AEF. GENETUL NOTES CRUSHED ROCK t1 ER ZONF_ REF. GENERAL NOTES NOTE: ILK E1.EYATIONS DEPICTED IN THE SECTIONS ARE BASED ON INFORMATON CONTAINED IN THE GEOVECH REPORT. THE ACTUAL ROCK EU -YAWNS WILL VARY. IF THE ANCHOR LfNMU INCREASES SY MORE THAN 10' LONGpR THAN THE .PL*3 INDIarF, A CONTRACT MOM17CATION IS WARRANTED. OCK ANCHOR' DETAIL UMESTONE