DFW Airport-PT130826 A copy of the approved permit must be on the job site at all times.
CC: Applicant r N e • c t r r - o F Page 1 of 4
Public Works COFFELL
Permit File Rev. 11/07
*, ;„' let.* �'"_a=' o it
Orig. to Project File c r 4 h _ 1 6 a
t\ppEowED
RIGHT-OF-WAY USE PERMIT APPLICATION
Per inn valid for 90 calendar dogs Iro,n date o/approval
Submit permit application to the Engineering Dept.,Town Center,255 Parkway Blvd.
Date of Submittal: 20 August 2013 Applicant's Job g/ Work Order rY 9500499, DO #6 / 3588 6
PERMIT FEE: 5100.00
(No charge to Utility Companies with approved Franchise/ROWV Use Agreement)
Refer to the City of Coppeli Ordinance No.2001-944. Certificated Telecom Provider? Y N
❑ Plans provided and approved
(Erosion Control/safety fences must be installed prior to beginning work)
Project Name/ Location: Relocation of DFW Aircraft Noise Monitor North Terminus of Hammond St in City ROW r
General Contractor: Phillips May Corporation Contact# 972-586-0038
Permit Issued to Company / Representative: DFW International Airport/Harvey Holden
Address: PO Box 619428,DFW Airport,Texas 75261-9428
Telephone N: 972-973-5570 _ Emergency Telephone#: 972-973-5562
Utility Company Represented:
❑Oncor Electric Delivery ❑Atmas Energy ❑Verizon ❑SIHC/ AT&T
Dime Warner Cable ❑CoSery Electric/Gas ❑Other DFW w'0ncor&Verson providing services.
General Description of Work(provide four NJ sets of plans): In accordance with Ord. No.2001-944.
Construct 8la1Win ground)X 2'diameter concrete pier. Move existing 20'noise monitor pole assembly from current
location on private property approximately 85'to new location in City ROW at northern terminus of Hammond St.cul-de-sac
972-973-5562
Estimated Start Date 20 August 2013 Estimated Completion Date* 18 September 2013
* Completion requires submittal of Completion Verification Notice(see page 4)
. Was contact made with City and/or utility companies to locate existing utilities?
if NO, Reason: YES NO
. Is removal of exiting streets, alleys,or sidewalks necessary? YES 0 NO 0
if YES, must have City inspection prior to concrete replacement
Right-of-Way Use Permit Application Page 2 of 4
Representative(s)of the Contractor must adhere to all construction standards approved by the City of Coppell, which
includes but is not limited to:Erosion Control Ordinance, compaction requirements (density tests may be required at
the applicants expense)and barricading according to the. Texas Manual on Uniform Traffic Control Devices.
Aren(s) affected must be restored to as good condition as before the commencement of work (grading,drainage,
vegetation,and erosion control). To schedule Public Works final inspection(Page 4)call 972-4624155.
i► Any excavation requiring closing of a street/alley must be reported prior to closing to the follossing:
Police Department 0 972-304-3600
Fire Department 0 972-304-3500
Street Department 0 972-462-5150
Engineering Department 0 972-304-3679
... Attach barricade plan/trench safety plan if a lane or street closure is required.
NOTE.: Street closures are allowed from 9:00 a-nt. until 3:00 p.m. ONLY unless otherwise approved by City
Engineer.
.. Attach Work Order(Franchise only)and/or 4 sets of prints showing proposed work.
LI I- --s /_.__. A /A C Y 1
ontacts must be made to locate existing utilities 48 hours prior to beginning work.
.. _ -_- , . .
(Application with original signatures should be submitted to the Engineering Department before approval.)
4
VI ��____ ..__ H.G. Holden 13 August 2013
Signature of Utility Company Representative Printed Name Date
NM --- Brian Mitchell 8/19/13
Signature of Contractor Representative Printed panne Date
,ee))4 &IV)\N e/b67d
Sigma are of City Representative Printed Name Date
Comments: Project Manager - Brian Mitchell 214-738-7161 (Cell)
Superintendent - Chris Mayeux 214-533-0153 (Cell)
r NOTE: Notify City Inspector at 972-304-3679 prior to beginning work and prior to
backfill for concrete, trench, Glitch and open pit inspections. Backfill must meet
all construction standards approved by the City of Coppell.
Applicant shall indemnify and forever hold harmless against the City of Coppell cads and evert' claim,
demand or cause of action that may be made or come against it by reason of or if any way arising out of the
closure, blocking, excavating, cutting, tunneling, or other work by the applicant under permit front the City,
if such permit is granted.
THIC • CITT • OF. Page 3 of 4
COPPELL
A A , 6
LTTILITI'RELOCATION CHECKLIST FOR WORK WIitiii'
CITY OF COPPELL RIGHTS-OF-WAY OR EASEMENTS
Listed below are minimum requirements for utility relocation projects:
1. A copy of the valid approved City of Coppell pemuit is required on the project at all times.
2. Notify adjacent property owners(commercial&residential)of project timeline;provide then with contact
names and phone numbers.
3. Proper erosion control measures must be taken.
4. Follow Texas MUTCD standards for work in traffic zones.
5. Sod is to be replaced when necessary.
6. Irrigation repairs must be petfomred in a timely manner.
7. Follow OSHA recommended trench safety at all times.
8. Repair existing utilities that are damaged,including but not limited to clean-outs,water valves,and SS
manholes.
9. Densities may be required in trench lines(ASTM).
10.Care and repair of street signage is the responsibility of the contractor.
11.No work is to be done in collector roadways before 9:00 a.m.or after 4:00 p.m.
12.Prior notice of work activity on weekends and holidays must be in writing.
13.Line locates must be performed in advance by contacting-1 800 DIG TESS andlor the following:
CITY OF COPPELL 1YI ILLITIES DIVISION cappelltx.gotitutility-operations-division
972/462-5155
CITY OF COPPELL ENGINEERING DEPT.
972/304-3679
HOMEOWNER ASSOCIATIONS
972/304-3678(Planning Dept.)
TIME WARNER CABLE FEDERAL EMERGENCY 3IGMT.ADMEN.
214/320-5455(Milne Rasmussen) 940/898-5138
AT&T LOCAL NETWORK TEXAS COMM. on ENVIRONMENTAL QUALITY
214/215-3031 (Rich Millenman) 817/588-5800
COSIRV Gas&Electric DENTON CO. LEVEE DISTRICT
940/321-7800 x 7624(Greg Ward) 214/352-5118(Richard Hightower)
EXPLORER PIPELINE Atmos Energy
918/493-5100(Patrick Nwakoby) 9721 360-4428 Gary Dickinson
ONCOR Electric Delivery 1 300 DIG TESS for line locales
972/323-8917(Larry Redick) (344-8377)or
VERIZON COMMUNICATIONS wv.w.texasonecall_c or
972/318-5277
14.Contaminants must be removed from work area daily and disposed of properly outside the City.
15.Streets, sidewalks and alleys must be kept clean of construction material and debris.
16."Clean-up" requires returning work area to pre-project condition or better.
17.Contractor is required to contact Public Works Division for Completion Verification Notice. (see pg. 4)
Page 4 of 4
T H H • C I T V • 0 R
CQFFELL
y c i � '
F k 8 4
UTILITY RELOCATION IN RIGHT-OF-WAY OR EASEMENT
COMPLETION VERIFICATION NOTICE
Contact City of Coppell Public Works Division at 972-462-5155 to schedule an inspection
with Utility & Streets personnel to verify that your project has been completed to City of
Coppell specifications. Failure to schedule verification inspection may delay fuhire projects.
Franchise Utility Name DFW International Airport
Project Location/Applicant's Work Order # (if applicable)
Northern terminus of Hammond Street cul-de-sac.
Sub-contractor Company Name Phillips May Corporation
24 hr.Contact Number 214-533-0153 - Chris Mayeux
Date of Verification Appointment
Time of Verification Appointment
INFORMATION BELOW TO BE COMPLETED BY CITY OP COPPELL PUBLIC WORKS PERSONNEL.
•3• Inspected by of UTILITIES Maintenance Division on
and found to be acceptable f not acceptable because
Follow-up needed? NO I YES Follow-up scheduled for
❖ Inspected by of STREETS Maintenance Division on
and found to be acceptable/not acceptable because
Follow-up needed? NO/YES Follow-up scheduled for
A copy of this completed notice is to be provided to:
City of Coppell Engineering Dept.
255 Parkway Blvd., Coppell TX 75019
Office: 972-304-3679 Fax: 972-304-3570
r
® N
r,
■ ...I I ......2=.,.. ",.../"."•• T.- ,,...10 ,_ , ,
City Property '`
Hard 8 Parking / '
xis
I
. .
1 x .
- ., . Private Property ;E
IPrivate Property
1/ .
ICreek Bed a;
Oabion Lined I
I t
Private Property
r-
-
45. ' I MONITOR NE6 I
Current Location
., NE6 Relocation Site in City of Coppell street ROW. —I.-
5
Location is the northern teminus of the Hammond St
cul-de-sac. (Lat.32°57'14.84" Long.97°00'30.01") ¢ , 'j}
t f.
�' , Oncor will bury power line in City ROW `:::!:f.' Ilt.
I Groun. ;
� ,w. �'
City Property 3
. ..,...
,_
„ .... f
., �
4
NE6 Relocation Site ; `
in City of Coppell _ m
�2013 Goagte � t '�.�;� ;;Ill
Ii-
street ROW. '� `�
32'5?'i4.89'N 9r`G�4'29 82"W ` Eye alt 608 ft - "
1
3
f l
\ , .
fitt ,
e
t - ' - -- ' ''
. . .
z..
t �. ,
.,. 0,.. ,
.,,, 4,........ ...... ,
4 .;,... '
....
_ .. . ,.....
,,•
. .
.. ..,.
..',.=,°'-',",� _ .„ it-,-: - I . .
,.,..; ,
12/1/200S 11:34am
"W its r> G +:�_
�, � t
hg f°'
k 3 g
` ,t
dt /f' ' \
L.
s`.
12/1/200511:44,m
t`
DFW: The Ft Noise rnp tibility Office Operates and �ti� aintains a Noise Monitoring
System that Spans about 110 Square Miles
Standard Layout for DFW Aircraft Noise Monitor Distribution of DFW Aircr=. .1b' ,.*n'
NW4 •NE4
''..''— — ''—. 'I.'''''''' 4' l'"x'--:
• NE7 •
NE3 NE8
•NW3
•
•NW6 •NW7 NE6
— N1W6
•NW2 tME2 y'NE1
Y s. :r`
NW1
E •NW5
r
i!til ,_ al
.$ „ . ': III +1
SW1 1 I 1,1(1 11
;r' r ..� •SW5 �! .0 eNE5
• SE1
•SW6 •SE5 *NE9,
SE6 wr SET
t "'j` •SV47
•SW2 •SE2 •
I SE6
''''-' -.';', v�
: I •SW8 •SE3 •x e
SE9
SW3
•SEA#
. SW4
.
LLLL I KR: LUNG I KUU I IUN PHIN I WH NU. 3213309
SHEET 1 C1t" 1
WR NAME COPPELL:RELOCATE UNDERGROUND SERVICE TO DFW NOISE MONITOR DATE 07-12-2013
-----------
Q CUSTOMER
DFW AIRPORT NOISE MONITOR SERVE 60
1�,�,/J —-- -- SERVICE CENTERFBR
ADDRESS 700 HAMMOND ST
----..--._-_.------- — OFFICE 191
LOCATION NEAR INTERSECTION OF BETHEL ROAD AND MAIN STREET
I MAPSCu
DESIGNER ALLEN,A1 REY JACK Q e 4- i 0 r 2 PROJECT MANAGER CAMPBELL,CHRISTOPHER PAUL
USER ID , PHONE NUMBER 072)323-8983
PHONE (972)323-8981
A.20', Orrcor Electric Delivery
Maps.drawings,and electronic data(pi edited ere created for the internal purposes of Incur Electric Delivery with no implication of suitability or fitness for the intended use of the recipient.Cncor Electric
Delivery will make good faith efforts to provide predicts that are free from er ,ur,but does not warrant the accuracy or quality of such products.The looations shown are door.:metiers and are not intended to
show exact locations.Products provided to other parties by Decor Electric Delivery are for the internal use of the recipient,and the ecipient agrees not to duplicate or distribute the products or any partxon of
the products to third parties without the prior written permission of boor Electric Delivery.The recipient further agrees to hold harmless and If Incur Electric Delivery against all claims,costs,expenses
and damages resulting from or predicated upon strict liability for personal injurres,death or property damage,on account of any defects in the property provided hereunder.
,yoiaxes.c : 1 d N o ., s iris e t-%`i"„',
eHF1 RD
,,,....../..„-„, ,, ,,,. ,,..,----r-v-'',"'"e'\."'N,r"kad..,e—,e',...'",,,r',"'''Ne''..",,,,,,,,
r, ccxr ° r 1 )t At X1, (-'x t
o ;x$' '' S-1-,.‘ b o as °" (
li
" 1.s ', ' ` t
IC:CONTACT
002 8 9 9 \
f a«a�ttf
...s
QJf 4 }
. S1625T
-3661301 - -.__ 1
1
1
-- -- 3
� � t,o • -r„
-- - \
.
T : B 50
.. ,,, ---- .., 3916547 '11-
,,,,,c,„ „,, ; -�--„ - , 0,, , , ,,,, -3661219
t c0r a i1 bares ,,
e0r- Co.,1rye -0 : .O ci I '°
f7 I , ` . ", 0 b 4 f t°t +r v° > o r w,.,,` e� n � ,
CO
A
O O
. .
10' .
111. U O
1.5' q
; q
1 5„ 1.06'1 DIAM HOLE •• -•
. TOP VIEW
( NOT SCALE)
r GALV.ANCHOR BOLTS
36"LENGTH WITH H 2 HOOK (A60)
TOP NUTS (A325)WITH
LOCK WASHERS • 20.00'
IIN 1 Lit
LEVELING NUTS(A325)
lit till
WITH LOCK WASHERS — --
�!,• ;._.....•.•:" :•:•:•: : :•:.:.... . :•:.:.:....•.•... . .®,
BASE PLATE
( NOT SCALE) •
AIRPORT NOISE MONITORING SYSTEM l Q
INSTALLATION DETAILS t
FOUNDATION/ MOUNTING
tanum MGA - Bi *2 , ,
IMO>R RLG_ ,1���'/
DIM R RL ��
e . FOUNDATION
=ztt H —. " T
1PT!»H R RVSL.. - ./ l •DALLAS/FORT WORTH VN� ?il���'rif�9fII`atratl'11�1�I4�tw Illltll(lli iCiillilkilu:hi 1,4 !
INTERNATIONAL AIRPORT
i NIL fargT•RE GREVE ASSOC/ATM
POWER 3/4' RIGID CONDU1I
TELEPHONE 3/4"RIGID CONDUIT
4-1"GALV.ANCHOR BOLTS
36"LENGTH WRH 2 HOOK ; STUB UP
1.80
2" ROUNDED RISE_ •
FOR DRAINAGE I0.5
5-#5 REBAR
200' CONCRETE MIX
t 4000 PSI-7 DAY
4 8-#3 BANDS •:• 3"MIN COVERAGE
111111 2.00'
- 2 3/4■SCHED 40 PVC CONDUITS
-- TELEPHONE/POWER
8'00 ' - :•;r 24'DIAMETER HOLE 8' DEEP
(USE AUGER OR HAND DIG)
-` : ' (USE 3 FT 24"DIAM SONOTU T
BE TO FORM)
SCALE 1P2 INCH- 1 FT
;a
THE
................ .......................;> FLOOD
AVCON
::............
.4•-- 2.00 --► GROUP AVIATION CONSULTANT
UNDISTURBED FOUNDATION HISDOCLfiENT TAINSC' a�'T'AL MAT�AL � V
TO ME•STRE GREVE ASSOCIATES.INC.Ater UNATHOURZED USE OSSCL,Q9u
DISSEMINATION ARESULT DUPLICATION► MY N UAau THE CA WS.