Loading...
CF-Cozby Library-LR 950308I G E GEE Consultants, Inc. E NVIRONMENTAL 2540 Glenda Lane · Suite 108 · Dallas, Texas 75229 · (214) 620-9791 · Fax (214) 620-9794 ROOFING INSPECTION REPORT Roofing Report No. 24 Page 1 of 2 Report Date: March 8, 1995 a~a~.g :a~ ~'~ Inspection Date: March 7, 1995 Standing Seam Roof Client: City of Coppell Project: W.T. Cozby Public Libra~' Single Ply Rnbber Membrane Roof Contractor: Diversified Construction Roof'mg Contractor: Bcrbice Corp., King of Texas Identification: Standing Seam Metal Roof, Single Ply Test Procedure: Visual Observations Weather Conditions: Partly Cloudy .Mnbient Temperature Range: 40°F iN'umber of Roofing Members: None Square Feet Laid: None Description of Operations: On this date, representatives of GEE Consultants, Inc. visited the above referenced site to perform a final inspection of the single ply and standing seam roof systems as well as building interior to check for leaks. The purpose of our observations were to determine conformance with plans and specifications and whether corrections of outstanding items noted in our Janua~, 31,1995 inspection had been made. Outstanding items are as follows: 1. Joint cover plates at perimeter coping of single ply system still missing. This may be an approval detail. 2. Few areas of poor securement of top clip at standing seams throughout main roof. Top clips should lock over standing seam panel cleats. Numerous locations between 7th and 8th panel west of northeast dormer. 3. Need to clean EPDM adhesive from base of west side of north skylight roof. 4. Notches still exist in panel standing seams at radius change (reverse curvature) areas above dormers. In addition, observ'ations of the inside of the building were made to look for signs of potential roof leaks. Stained ceiling tiles were observed at the following locations: 1. Southeast corner of building. 2. East end adjacent to fire sprin~er head. 3. Small closet at northeast corner of building. Our letters and repoxna are for the exclusive use of the cheat to whom they are addressed. The use of our name must receive our prior wriuen approval. Our letters and reports apply cml)' to the sample tested and:or inspected, and are not necessarily indicative of the quantifies of apparently identical or similar products. GEE Consultants, Inc. 214-620-9791 ROOFING hNSPECTION REPORT Roofing Report No. 24 Page 2 of 2 Report Date: Ma~h 8, 1995 Inspection Date: March 7, 1995 Standin~ Seam Roof Client: City of Coppell Project: W.T. Cozby Public Library Simile Ply Rubber Membrane Roof Contractor: Diversified Construction Roofing Contractor: Berbice Corp., King of Texas Identification: Standing Seam Metal Roof, Single Ply Test Procedure: Visual Observations (cont.) Access to rooms along the east side of the building entry, hall could not be gained due to construction activities. The above observations were verbally brought to the attention of Mr. Terry Bane with Diversified Construction. Mr. Bane stated the stained ceiling tiles occurred from an overnight rain. He stated he knew of no other evidence of roof leaks. We recommended he contact his roofers to repair leaks occurring at the stained ceiling tile locations. cc: Ga~ Sieb - City of Coppell Larry Davis - City of Coppell Scott Johnson - Diversified Construction Sen, ices, Inc. Jim Bullock - F & S Partners Russell Williams - Brockette Davis Drake, Inc. Technician: R.G.' Our letlers and reports are for the exclusive usc of the ¢llent to whom they ~-~ addressed. Thc usc of our nam~ must receive our prior wriucn approval. Our letters and r~ports apply only to ~he sample tes~l ancb'or inspected, and am not necessarily indicative of the qua~ti, tics of app~,-~tly identical or similar products.