Loading...
CF-Cozby Library-LR 941021G EOTECHNICAL E GEE Consultants, Inc. 2540 Glenda Lane · Suite 108 · Dallas, Texas 75229 · ~'~ ~ .,~ ._14, 620-9791 · Fax ~'~14", 620-9794 REPORT OF CONCRETE MIX INSPECTION Report Date: October 21 , 3.994 Date Concrete Placed: September 21, 3.994 Standard 6"x12" Client: City of Coppell Area 28.27 Square Inches Project: W.T. Cozby Public Library Concrete Repo~ No. 28 Contractor: Diversified Construction Services, Inc. Concrete Supplier and Plant: Texas Industries, Inc. - Plant #41 Location of Placement: Concrete Pavement, North Parking Lot MATERIALS s~.~.' SSD S.,ch w,,. INSPECTION DATA I~ser. i~ion fL~ CuYd] Mix Number: 8203 Time Sample Batched: 12:00 pm Cement: Time Sampled: 12:20 pm Sample Location: 55' east of west end. 30' south of north end Fly Ash: Truck'Ticket No: 97:276251 Coarse Aggregate: 1" C.S. Temperature: Intermediate A,,gregate: Ambient Range: 82°F Fine Aggregate: Concrete Range: 86°F Slump Range (inches): 6-'.~; to 7 Admixtures: Weatl{er Conditions: Partly Cloudy I Admix Time Started: 7:30 am 2 AEA Time Completed: 4:30 pm Added Water: 15 gal. Sample Air Content (/'Te): 4.0 Total Cubic Yards Placed: 140.0 C.Y. Required Strength (Lbs.:sq.in.): 3.000 S~n Mc~tm:d A~ ~m Tc~l Load C~ms~ix'¢ St~ng~ ~r~ N~r Sl~p: b.~ :~> s: Tcs~ ~L~.~ L~. 'Sq.b.) WTC 131 7" 7 09/28/94 78,260 2,770 WTC 132 7" 7 09/28/94 79,840 2,820 WTC 133 7" 28 10/19/94 106,560 3,770 WTC 134 7" 28 10/19/94 103,440 3,660 WTC 135 7" Hold Hold Test Mee~ls t.'dlO~ Fracture R~ar Cylinders Made By: R G A~M C-3l,C-39.C-143 ft:~ess N~ O~'~; - - ' ' Remarks a~/or Distribution: cc: Gary Sieb - City of Coppell Larry Davis - City of Coppell Mike Sherpinskas - Diversified Construction Services, Inc. Jim Bullock - F & S Partners Russell Williams - Brockette Davis Drake, Inc. GaR Consultants, Inc. Reviewed by: / .('~. _.~.~'~'-~ -- (-__~/ All letters and ~porcs as~ fo~ uh~ exciuai',~ u~ of ~ cli~m to whom they ate addn:~M and ah,il no~ be. ,-¢pradu~:d ~.'i,.hout ti~ ~ail a.egroval of GEE Comui'.a~l$. Inc. 'Dx: usa: of oux rau'm: must out prior written appto~al. Our k:tt~es ami r~portm apply only ua I~ samp. 1~ ~s,..a ~:~,'or i~l:~'~.~l ~ a~c rso~ ,~ssarily indicati~ of rig quantities of a.upar~mly i~n:ical or sin-filar pro~m.~s.