CF-Cozby Library-LR 941020I G 'EOTECHNICAL
E GEE Consultants, Inc.
2540 Glenda lane · Suite 10g · Dallas, Texas 75229 · {214! 620-9791 · [ax !214~ 620-9794
REPORT OF CONCRETE MIX INSPECTION
Report Date: October 20, 1994 Date Concrete Placed: September 21, 1994 Standard 6"x12"
Client: City of Coppel 1 Area 28.27 Square Inches
Project: W.T. Cozby Public Library Concrete Repon No.27
Contractor: Diversified Construction Services, Inc.
Concrete Supplier and Plant: Texas Industries, Inc. - Plant #41
Location of Placement: Concrete Pavement, North Parking Lot
MATERIALS so~' SSD s,,c~ w~.
I~,cE. :p:ion ,'Lb~.'CuYd ) INSPECTION DATA
Mix Number: 8203 Time Sample Batched: 8:38 pm
Cement: Time Sampled: 9:20 pm
Sample Location: 50' south of north end, 24' west ofconst.joint
Fl','. Ash: Tmck;q'icket No: 9'~ .... "~'~6039
Coarse Aggregate: 1" C.S. Temperature:
Intermediate Aggregate: Ambient Range: 8,~,o F
Fine Aggregate: Concrete Range: 82°F
Admixtures: Slump Range (inches): 6h to 7
Weather Conditions: Partly Cloudy
1 Admix Time Started: 7:30 am
9 AEA Time Completed: 4:30 pm
Added Water: Sample Air Cotttent (%): 3.3
Total Cubic Yards Placed: 50.0 C.Y.
Required Strength (Lbs./sq.in.l: 3,000
Specimen .M~asu:ed Age Dam Tetal Loa~ C~.w. pmss[~ Sm:ng~ Remargs
Number Sitar.? ,iv..: ;Da?si TeS'o~l ~Lb~.! ,Lbs. Sq.ln.;
WTC 126 6% 7 09/28/94 70,180 2,480
WTC 127 6% 7 09/28/94 76,080 2,690
WTC 128 6% 28 10/19/94 94,400 3,340
WTC 129 6~ 28 10/19/94 105,860 3,740
WTC 130 6~ Hold Hold
Test 5.l¢~hc~ t't~lhc~ Fmc~urc Regular
ASTM C-31.C-39. C-'43 .L:nlcss Noted O'.hcrJ,;~..¢ Cylinders Made By: R · G.
Remarks and:or Distribution:
cc: Gary Sieb - City of Coppell
Larry Davis - City of Coppell
Mike Sherpinskas - Diversified Construction Services, Inc.
Jim Bullock - F & S Partners
Russell Williams - Brockette Davis Drake, Inc.
G~ Consultants, Inc. Reviewed by: ~ ~'
All Ictte.-s ard .-cpo~ am ,"er ~:-g ~¢:usivc x ef~.~ ¢!k:m :o ~.-ho~ ,.~y am ,~[,'*.ss~ and siall r~ ~ ,'~p~edu,:*:l wi'.ho~ :~ full ar. proval of GEE Comuitant$. Lq,:. 'Fac ~ vf our narr~ must mcc::-c
our prior written appr~'al. Our icttcv.~ and reports appi? only to thc sample tc$'.ed and/or imlr. c~[ ~xt am n~ rgcgas~rily k~l:cativc of tim quantities of app.a.-cvaJy kScn:ic'ai or sireJ[ar prod,ac.s_