ST9902-LR131014 (2)Is � Consulting Engineering'` Geotechnical Engineering'` Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Date Sampled: 10/07/2013 Report Date: 10/15/2013 Previously Reported: 10/09/2013 Sampled By: Roberts, Duce Project: West Sandy Lake Road By Order Of: Location: Abutment 1, backwall 2nd pour, Abutment 1, south wing wall 2nd Order Number: 1770 pour Number of Client: City of Coppell Specimens: 5 REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 152913 Material: Concrete Test Method: See Below TEST RESULTS Report No: 152913 Page 1 of 1 Specification Strength: 3,600 psi @ 28 days Slump: 3 -5 Air Content: 3 -6 Date Received: 10/08/2013 Curing Method: Maximum Time Sampled: Spec Age Tested Diameter Area Load 80 °F Mix: 78 °F Nbr (date : days) (in) (in Z) (Ibs) Break Type A 10/10/13: 3 6.00 28.27 76,495 Type 3 B 10/14/13: 7 6.00 28.27 93,355 Type 3 C 10/14/13: 7 6.00 28.27 92,125 Type 3 D 11/04/13:28 6.00 28.27 E 11/04/13:28 6.00 28.27 Type 1 Type 2 Type 3 Specification Strength: 3,600 psi @ 28 days Slump: 3 -5 Air Content: 3 -6 Date Received: 10/08/2013 Curing Method: Standard Time Sampled: 1:30 pm Time Batched: 12:24 pm Temp.: Ambient: 80 °F Mix: 78 °F Compressive Cure Strength Loc (PSI) Lab 2,710 Lab 3,300 Lab 3,260 Lab Lab F-111 Type 4 Average Strength Tested (PSI) By Comments 2,710 3,280 FIF] [� Type 5 Type 6 Slump: 4.25 Inches Air Content: 4.6% Mix Code: 5409 Transported By: LMC Source /Sampled At: Truck / Center Plant: 952 Truck /Ticket No: 1407 / 62955004 Quantity Represented: 8 cu. yds. at 8 cu. yds. placed of a 8 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORTAPPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.