Loading...
MA1009-LR130913 (2) Concrete Compression Test Report 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client:Report Distribution:(90) kmarvin@coppelltx.gov City of Coppell (90) steve@jdkassoc.com Project: Erosion Control for Andy Brown (90) kdykes@tnpinc.com Park and Alex Drive Canal (90) asamaniego@coppelltx.gov Project No. MA10-09 (90) radloo@coppelltx.gov 687-13149-003 CMJ Report No.: (90) jelias@coppelltx.gov 09/17/2013 Report Date: Specifications Test Data 08/16/2013 1500 psi @ 28 DaysPlacement Date Strength n/aSampled ByRandy Ehart Slump n/aCloudy/Calm Air ContentWeather n/aRedimix/U4001561 Concrete TemperatureSupplier/Mix ASTM C231 n/aAir Content Method Ambient Temperature Field Data Set #01 2570946909:3910:20 Ticket Number:Time Batched:Time Sampled: 1.75 in1.1 % Slump:Air Content:Unit Weight: 10 of 30 Yardage (c.y.): 93° FAmbient Temperature: Concrete Temperature:70° F Retaining Wall Along Creek Placement Location: Sample Location: Section B at 450 Concrete Compression Test Results CylinderAgeMax LoadAreaStrengthFracture Set ##Test Date(days)(lbs. force)(sq.in.)(psi)Type 01CEC08161301*08/23/2013 7 12010C-cone/shear 12.63950 01CEC08161302*09/13/2013 28 14840D-shear 12.571180 01CEC08161303*09/13/2013 28 15200D-shear 12.571210 01CEC0816130410/11/2013 56 28 day average 1200 Normal cylinder size: 4" x 8"; Fracture Types A,B,C,D,E=1,2,3,4,5 Respectively The average 28 day compressive strength test results do not meet specifications. Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. 0 Gallons of Water Added On-Site * 7-DAY TEST RESULT INDICATES A MARGINAL 28-DAY COMPRESSIVE STRENGTH - * 28-DAY TEST RESULTS NON-COMPLIANT; Hold cylinder will be tested at 56-days (*) Notifications: Keith Marvin with the city of Coppell, TX via email: kmarvin@coppelltx.gov and Albert Samaniego with the city of Coppell, Tx via email: asamaniego@coppelltx.gov R. Carl Digitally signed by R. Carl Lee DN: cn=R. Carl Lee, o=CMJ Engineering, Inc., ou=CMT Lee Department, email=clee@cmjengr.com, c=US Date: 2013.09.18 07:56:28 -05'00' CMJ Engineering, Inc R. Carl Lee, S.E.T. Vice President/CMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. Page 1 of 1 01