Loading...
DR1201-LR131003 OCT-18-2013 05:00 P.06 A Texas CMT, Inc. /111PA . . Construction Materials Testing GEE Consultants, Inc. and Environmental Consulting 10044 Monroe Drive •. Dallas, Texas 75229 • (214) 352-6957 • Fax (214) 352-6972 • www .texascmt.com REPORT OF CONCRETE MIX OBSERVATION Report Date: October 14, 2013 Date Concrete Placed: September 5,2013 Standard 6"x12"Cylinders Client: City of Coppell Cylinder Cross-sectional Area:28.27 Square Inches Project: Creekview Drive Roadway Improvements 2013, Coppell,Texas Concrete Report No.: 08 Contractor: The Fain Group Project No.:213-0134 Concrete Supplier and Plant: Redi-Mix Concrete /P259 Location of Placement: Commercial Firelane Inlet Top&Junction Box Walls ' MATERIALS Source/ SSD Batch Wts. OBSERVATION DATA Description (Lbs/CuYd) Mix Number: 10111524 Time Sample Batched: 9:24 AM Cement: 5 Sack Time Sampled: 10:33 AM Fly Ash: Sample Location: Junction Box Walls at S.W.Portion of Project Coarse Aggregate: Truck/Ticket No: 1321 /0108 Intermediate Aggregate: Temperature: Fine Aggregate: Ambient Range: 89°F Admixtures: Concrete Range: 94°F .. Slump Range(inches): 3.25 I Weather Conditions: Clear • 2 . Time Started: 9:30 AM Added Water: • Time Completed: 12:00 PM Sample Air Content(%): • 3.1 • Total Cubic Yards Placed: 10 Required Strength(Lbs./sq.in.): 4,000 . Specimen Measured Age Date Total Load Compressive Strength Remarks Number Slump(in.) (Days) Tested (Lbs.) (Lbs./Sq.In.) CV 29 7 9/12/13 99,460 3,520 CV 30 28 10/3/13 118,660 4,200 • CV 31 3.25 28 10/3/13 119,200 4,220 CV 32 H Hold Test Methods Utilized Fracture Regular Cylinders Made By RG ASTM C-31, C-39, C-143 (Unless.Noted Otherwise) Remarks and/or Distribution: cc: Mr. Larry Davis- City of Coppell, Phone: 972-304-3684; via Fax: 972-304-3570 Mr. George Marshall - City of Coppell, Phone: 972-304-3562; via E-mail: gMarshall @coppelltx.gov Mr. Rod Lacy- The Fain Group, Phone: 817-927-4388; via E-mail: rlacy @faingp.com 021,1:60,.....___— Texas CMT, Inc. TBPE Firm: F-4521 Reviewed by: All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the fall approval of Texas CMT,Inc. The use of our name must receive our prior written approval. Our letters and reports apply only to the sample tested and/or observed and are not necessarily indicative of the quantities of apparently identical or similar products.