CF-Cozby Library-LR 940616G EOTECHNJCAL
ENGINEERING GEE Consultants, Inc.
E INVIRONMENTAL
2540 Glenda Lane · Suite 108 · Dallas, Texas 75229 · (214) 620-9791 · Fax (214) 620-9794
REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOIl.
Method: ASTM D2922 D3017 D698 Page ! of 1
Client: City of Coppell l~teriai Ocacriotion btaximum Optimum
Dp Moisture
Dcusi .ty Content
Project: W.T. Cozby Library (Lbs/¢uFt) Per¢~t
Test Date: June 13, 1994 1. Dark Gray Clayey Sand 101.5 15.9
Report Date: June 16, 1994 2.
Required Densit3/ (%): 95% to 105%
Required Moisture (%): -1-3% Optimum
~lst Location/Elevation (and/or) Li~ in-mace ~n-P'-ce Pcr=~nt
No. DH DcnslV,.' Moisture Compaction
Test
No. (Lbs/CuFt) Content
Depth
1 Utility clitch, gas line, outside building line, 1't lift
g6 101.2 17.1 99.7
6" 100' west of northeast corner
1 Utility, direly, gas line, outside building line, 1't lift
g7 93.2 23.0 91.g
6" 65' south of nortlawest corner
Above test results meet specification requirements
¢¢: Gary Sieb - Cit~ of Coppcll
Larry Davis - City of Coppell
Mike Sherpinskas - Diversified Construction Services, Inc., ??/f
Jim Bullock - F & S Partners '
Our letters and reports are for thc exclusive use of the client to whom they are addressed. The usc of our nnme must receive our prior written approval. Our
leucrs and reports apply only to the sample test,'d and/or inspected, and are not necessarily indicative of the quantities' of apparently identical or similar products.