CF-Cozby Library-LR 940616 (2)G EOTECHNICAL
ENGINEERING GEE Consultants, Inc.
E J NVIRONMENTAL
2540 Glenda Lane · Suite 108 · Dallas, Texas 75229 · (214) 620-9791 · Fax (214) 620-9794
REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOll.
Method: ASTM D2922 D3017 D698 Page I of 1
Client: City of CoppeH Malerial Description Maximum Optimum
Dry. Moisture
I)ensity Content
Pr~ect: W.T. Cozby Library (Lbs/CuFt) Percent
Test Date: June 14, 1994 1. Dark Gray Clayey Sand 101.5 18.9
Report Date: June 16, 1994 2.
Required Density (%): 95% to 105% 3.
Required Moisture (5~): +3% Optimum 4.
Mat Location/Elevation (and/or) Li~ tn-Pace tn-Place Percent
No. Dz' Densiw Moisture Compaction
Test (Lbs,'CuFt) Content ( % }
No.
Probe
Dc'pm
1 Utility ditch, roof drain along north side of the building,
88 outside the building line, 1st lift 105.3 20.5 103.7
6" 100' east of northwest corner of the building
cc: Gary Sieb - City of Coppell .,,~,,
Larry Davis - City of Coppell " / , ,
Mike Sherpinskas'- Diversified Construction Services, Inc.
Jim Bullock - F & S Partners
Robert Williams - Brockette Davis Drake, Inc.
Our letters and reports are for the exclusive use of~he client to whom they are addressed. The use of our name must receive our prior written approval. Our
letters and repo~s apply only to the sample tested and/or inspected, and are not necessarily indicative of the quantities of apparently identical or similar products.