Loading...
CF-Cozby Library-LR 940624I G EOTECHNICAL E GEE Consultants, Inc 2540 Glenda Lane · Suite 10g · Dallas, lexas 75229 · (214) 620-9791 · Fax (214) 620-97~_ STATISTICAL ANALYSIS OF CONCRETE DESIGN Repo~ Date: June 24, 1994 Sample Da~: June, 1994 Client: City of Coppell P~ject: W.T. Cozby Public Library Identification: Statistical Analysis of Compressive Strength Test Results Me~hod of Test: ACI 214-77, ACI-318 Mix No: 45 Required Compressive Strength at 28 da>,s: 3000PSI Month ending: June, 1994 Test Cast Average 7 Day Average 28 Day 28 Day Moving Cumulative No. Date Strength (PSI) Strength (PSI) Average of Last 3 (PSI) 28 Day Average (PSI) Remarks WTC 51 5/14/94 2.900 4,050 --- 4,050 WTC 56 5/20/94 3,120 4,545 --- 4.298 %%rl'C 61 5/24/94 3,080 Total number of completed 28 day tests: 2 28 day average compressive strength (PSI): 4,298 28 da,,' standard deviation (PSI): 350 28 day coefficient of variation (%'1: 8.1 cc: G~y. Sieb-City of Coppell "///: ~' & Larry. Davis- City of Coppell ~.~.,~~ Mike Sherpinskas - Diversified Construction Services, Inc. Jim Bullock - F & S Partners Russell Williams - Brockette Davis Drake, Inc. AR b't~rs and aeago~ are for the cxch~i%~ uae of the client to ~.'l~rn ~ ate addeeaaed and shall not b~ mproduagd without ~e full appt~'al of GEE C~, Inc. The use of otur r~tr~ mgm reogive out prio~- written aP~Wovm. Out ie~ts and i~-po~Is ap~ly mxly to th~ snmpk tealed and/or impected and am nm neceeaatily indicative of th~ ClUamitie~ of a~mmly identical or similar fnodueta.