WA9302A-CS 971001 SHIMEK, JACOBS & FINKLEA, L.L.P. 8333 Douglas Avenue, #820 Dallas, Texas 75225-5816 Fax (214) 361-0204 Phone (214) 361-7900 ROSS L. JACOBS, P.E. RONALD V. CONWAY, P.E. JOHN W. BIRKHOFF, P.E. JoE R. CARTER, P.E. October 1, 1997 GARY C. HENDRICKS, P.E. I. C. HNKLEA, P.E. Mr. Michael Daigre Noah Tex Municipal Construction Co., Inc. 5614 D r Street Dal'4?l~a~~~206 Re: City of Coppell Village Parkway Pump Station Additions Dear Mr. Daigre: We are in receipt of your letter dated September 29, 1997, which indicates that G.E. Team Controls, Inc. has completed the punch list dated September 26, 1997 and that the SCADA portion of your contract with the City of Coppell is complete and ready for service. As such, we conducted a final inspection of the SCADA system on September 30, 1997. In attendance were: Mr. Matt Cast, City of Coppell Mr. Larry Davis, City of Coppell Mr. Ted Dutt, City of Coppell Mr. Steve Baker, G.E. Team Controls Mr. Gary Hendricks, P.E., S.J.& F., L.L.P. The following items on the Sept. 261h punch list remain incomplete or not complete to the satisfaction of the City: 1. Pump No. 4 is still in the pump rotation sequence. It is the lead pump in the 100% summer sequence. Obviously, Pump No. 4 does not exist. Apparently, this causes none of the pumps to be called. Pump No. 4 needs to be removed from all pump rotation sequences set up and all sequences need to be test for reliable operation of the system. 2. The Moore Road pressure point appears to still be reading a constant 50.0 psi no matter what is happening in the system. This needs to be corrected. The City of Coppell understands this may be a problem at their end. However, a coordinated effort to correct this problem needs to be a priority. 3. The City of Coppell still believes the external modem on the original SCADA computer ( Computer No. 1) is part of the equipment they supplied. Steve Baker could not confirm this at the time of our walk through. This issue needs to be resolved prior to final acceptance of this portion of the contract. 4. Re-calibrate the pressure transmitters at the Ground Storage Tanks to match the 0-50 foot scale of the Elevated Storage Tank so that the level trends of all three can be viewed on the same graph. Mr. Michael G. Daigre "" North Teias Municipal Construction Co., Inc. October 1, 1997 Page No. 2 In addition to these items, the following items were reviewed and found to be in need of correction: 1. The City of Coppell provided us with a copy of the "Monthly Reports" print-outs at this meeting. This was our first opportunity to review these print outs. In general, the information contained in the reports contained no recognizable units and could not be readily compared to the data on the SCADA System. However, even with this problem and using our best judgment as to the correct units on the reports, none of the data seemed on the reports seemed to match the information we produced either from the SCADA system or the circular charts. We marked up the corrections we could identify on the reports and gave the originals to Steve Baker. A copy of our comments are attached to this letter for your records. 2. Larry Davis noted that the record drawings for the SCADA System have not been revised to show the configuration of the second computer and how it is integrated into the system. Our brief review of the drawings indicate at least three of the drawing will need to be corrected. Although the original pump station contract was complete to the City's satisfaction prior to September 30, 1997, the SCADA System change order remains incomplete. As such, the City has directed us to inform you that a contract deduction in the amount of $500 per day will be applied to the SCADA portion of your contract, starting today October 1, 1997, and continuing unti! the SCADA System is complete in all respects, acceptable to the City of Coppell and operating in a reliable manner. The City understands this subcontract work by G.E. Team Controls is a specialty item and is primarily beyond your control. The City does not wish to impart liquidated damages on North Texas Municipal Construction Co. Therefore, if you agree to the $500 per day SCADA deduction, a change order will be issued upon final acceptance of the SCADA System which will include the total SCADA System deduction, and a contact time extension will be granted. A preliminary copy of the proposed change order is enclosed for your review. Please review this interim agreement and notify us of your acceptability by signing in the space provided below. If you have any question or wish to discuss this proposal further, please do not hesitate to contact this office. Sincerely s cEcn.'cl~n Griffin, P.E. Mr. Matt Cast G. E. Team Controls APPROVED FOR NORTH TEXAS MUNICIPAL CONSTRUCTION CO.: By.' Mike Daigre, President Date J:\Coppell~94156~onst~scpunch5.doc CITY OF COPPELL, TEXAS VILLAGE PARKWAY PUMP STATION ADDITION PROJECT NO. WA-9302 BID NO. Ql195-02 CHANGE ORDER NO. 6 rRevised) A. INTENT OF CHANGE ORDER The intent of this change order is to modify the provisions of the contract entered into by the City of Coppell, Texas and North Texas Municipal Construction, Inc., 5614 Dyer Street, Dallas, Texas 75206, for construction of the Village Parkway Pump Station Addition, dated January 9, 1996. B. DESCRIPTION OF CHANGE 1. The City of Coppell hereby agrees to a request by North Texas Municipal Construction Co., of contract time extension of 110 calendar days. 2. Pay Items Nos. 4, 5 and 6 are not required to complete this project and are eliminated by this Change Order. 3. North Texas Municipal Construction Co., hereby agrees to a reduction in the total contract amount of $2,275. 4. North Texas Municipal Construction Co., hereby agrees to a reduction in the SCADA Change Order (Change Order No. 2), in the lump sum amount of $x, xxx (to be calculated at $500 per day from 10/1/97 until final acceptance of the SCADA System) C. EFFECT OF CHANGE ON CONTRACT AMOUNT This change will have the following affect on the final contract amount: Original Revised Change Revised Item Contract Contract Order Contract No. Description Units Quantity Quantity Unit Price Amount 4 Extra Class "A" Reinforced Concrete C.Y. 25 0 $350.00 ($8,750.00) 5 Extra Class "C" Concrete Backfill C.Y. 25 0 300.00 ($7,500.00) 6 Extra Crushed Stone C.Y. 25 0 35.00 ($875.00) 30 Contract Amount Adjustment L.S. 0 1 ($2,275.00) ($2,275.00) 31 SCADA System Contract Adjustment L.S. 0 1 ($x,xxx) ($x,xxx) Total Amount of Change ($19,400.00) J:\Coppell\94156\Specs\CO-6.doc Page 1 of 2 'City of Coppell ~' ,~, Village Parkway Pump Station Addmons Change Order No. 6 Original Contract Amount $933,000.00 Amount, Change Order No. 1 (5,000.00) Amount, Change Order No. 2 152,739.00 Amount, Change Order No. 3 18,415.00 Amount, Change Order No. 4 2,991.00 Amount, Change Order No. 5 8,552.00 Amount, Change Order No. 6 (19,400.00) Revised Contract Amount $1,091,297.00 D. EFFECT OF CHANGE ON CONTRACT TIME The changes identified above will add 110 calendar days to the revised contract time. Original Contract Time: 300 Calendar Days Calendar Days, Change Order No. 1 0 Calendar Days Calendar Days, Change Order No. 2 60 Calendar Days Calendar Days, Change Order No. 3 0 Calendar Days Calendar Days, Change Order No. 4 30 Calendar Days Calendar Days, Change Order No. 5 30 Calendar Days Calendar Days, Change Order No. 6 110 Calendar Days Revised Contract Time 530 Calendar Days E. AGREEMENT By the signatures below of duly authorized agents, the City of Coppell, Texas and North Texas Municipal Construction Company, Inc., do hereby agree to append this Change Order No. 6 to the original contract between themselves, dated January 9, 1996. City of Coppell, Texas North Texas Municipal Construction Company, Inc. Owner Contractor By: By: Date: Date: Attest: Attest: J:\Coppell\94156\CO-6.doc Page 2 of 2 I 10/81/1997 10:45 214-3G1Z..-~t204 SHiMEK,JACOBSgTKLE PAGE 81/05 ,,, SHIMEK, JACOBS & FINKI.EA, L.L.P. CONSULTING ENGINEERS 8333 Douglas Avenue, #820 Dallas, Texas 75225-5816 Fax (214) 361-0204 Phon~ (214) 361-7900 FAX TRANS~SSION COVER SHEET Fax Number: From: Gary Hendricks Number of Pages Transmitted (including this one) I ~ ! Date: Ootober 1, 1997 To: Mr. Kenneth M. Griffin, P.E. City of Coppeli Post Office Box 478 Coppell, Texas 75019 Kerl: Fake a look at this draft letter and change order to see if it meets the intent of our meeting yesterday. Ken, since we are changing the intent of the original "gentlemen's" agreement we discussed with Mike, I thought both you and he would like this one to be a little more formal. Therefore, I have included an acceptance block for the contract at the end of the letter. L~t me know if you think this is necessary.