Loading...
CF-Cozby Library-LR 940520 (05) REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOIL Method: ASTM D2922 D3017 D698 Client: City of Coppeil Material Description Maximum Optimum Dr)' Moisture Densi~' Content Project: W.T. Cozby Library (Lbs.'CuFf) Percent Test Date: April 6, 1994 1. Select Fill: Reddish Brown Clayey Sand 112.5 13.2 Report Date: May 20, 1994 2. Required Density (%): 95% to 105% 3. Required Moisture (%): +3% Optimum 4. Mat Location/Elevation (and/or) Lift In-Place In-Place Percent Test No. DO· Density Moisture Compaction No. (LbslCuFI) Content (~) Probe Dep0~ 1 Building Pad Select Fill - 1st Lift 21 112.2 12.3 99.7 6" 30' north and 90' east of southwest corner 1 Building Pad Select Fill - 1st Lift 22 110.5 13.9 98.2 6" 60' north and 80' east of southwest corner 1 Building Pad Select Fill - 1s' Lift 23 116.0 11.6 103.1 6" 6' south and 90' east of northwest corner 1 Building Pad Select Fill - 1st Lift 24 109.0 13.9 96.9 6" 30' east and 24' north of southwest comer Above Test Results Meet Specification Requirements cc: Gary Sieb - City of Coppell Mike Sherpinskas - Diversified Construction Services, Inc. Jim Bullock - F & S Partners Robert Williams - Brockette Davis Drake, Inc. Our k:tters amt re:ports arc: for Ih~ e. xclmive us~ of Ih~ client to whom tigy am addressed. Th~ u~ of our name mint re. cei,.~ oaa' prior ~..ritten approval. Our letters ~ reports apply only to ti~ sam~p~ testod and:or imp~-~, and am no( ne,~essarily irglicativ~ of th~ quantitle~ of apgan:ntly identical of similar In'oduc~.