ST9902-LR131031ALLIfiFiCE
GEOTE[tihlCML..
!GRC7UP
Acct ID: 1770
Report Date: 10/25/2013
Project: West Sandy Lake Road
Location: Various Locations
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C13 -0634
Date Sampled: 10/24/2013
Sampled By: Hernandez, Caleb
By Order Of:
Order Number: 1770
Client: City of Coppell
REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 153739
Test Method: See Below
TEST RESULTS Report No: 153739
Page 1 of 2
Set: 1 of 2
Material: Concrete Number of Specimens: 4
Location: Inlet and Inlet Top of Lat F2A; Sampled Inlet Lat 7A1 Line F on Southeast Corner of Intersection East of Whispering Hill
Maximum Compressive Average
Spec Age Tested Diameter
Area Load Cure Strength Strength Tested
Nbr (date : days) (in)
(in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments
A 10/31/13: 7 6.00
28.27 76,775 Type 3 Lab 2,720 2,720
B 11/21/13:28 6.00
28.27 Lab
C 11/21/13:28 6.00
28.27 Lab
D
HOLD (see remarks) -
Hy-j r i_ El
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Specification
Strength: 3,600 psi @ 28 days
Slump: 3 -5
Slump: 4.0 Inches Transported By: LMC
Air Content: 3 -6
Air Content: 5.0% Source /Sampled At: Truck / Center
Mix Code: 1261 Plant: 952
Date Received: 10/25/2013
Truck /Ticket No: 9102 / 62955761
Curing Method: Standard
Time Sampled: 3:00 pm
Time Batched: 1:49 pm
Temp.: Ambient: 81 °F Mix: 82 °F
Quantity Represented: 6 cu. yds. at 6 cu. yds. placed of a 6 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Acct ID:
1770
Report Date: 10/25/2013
Project:
West Sandy Lake Road
Location:
Various Locations
Client:
City of Coppell
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C13 -0634
Date Sampled: 10124/2013
Sampled By: Hernandez, Caleb
By Order Of:
Order Number: 1770
REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 153739
Test Method: See Below
TEST RESULTS Report No: 153739
Page 2 of 2
Set: 2 of 2
Material: Concrete Number of Specimens: 5
Location: Junction Box Top (Box Culvert
Line F and Line G); Sampled Station 1 +00 on West Sandy Lake Rd, Junction Box Top
Maximum Compressive Average
Spec Age Tested Diameter
Area Load Cure Strength Strength Tested
Nbr (date : days) (in)
(in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments
A 10/27/13: 3 6.00
28.27 110,630 Type 3 Lab 3,910 3,910
B 10/31/13: 7 6.00
28.27 118,010 Type 3 Lab 4,170 4,170
C 11/21/13: 28 6.00
28.27 Lab
D 11/21/13:28 6.00
28.27 Lab
E
HOLD (see remarks) -
E]
R- FI 11
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Specification
Strength: 3,600 psi @ 28 days
Slump: 3 -5
Slump: 5.0 Inches Transported By: Southern Star
Air Content: 3 -6
Air Content: 3.5% Source /Sampled At: Truck / Center
Mix Code: 1083 Plant: 110
Date Received: 10/25/2013
Truck /Ticket No: 3555 / 1314042
Curing Method: Standard
Time Sampled: 4:10 pm
Time Batched: 3:25 pm
Temp.: Ambient: 811F Mix: 82 °F
Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
A?11
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
L1If'�YCE
I � 4 k!GE0TE-CM1C19L
Rf.7UP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770
File No: C13 -0634
Curing Method:
Standard
Date Sampled: 10/03/2013
Report Date: 11/01/2013 Previously Reported: 10/11/2013
Time Batched:
1:19 pm
Sampled By: Roberts, Duce
Project: West Sandy Lake Road
By Order Of:
Location: Abutment #1 Backwall - First Pour; South Wing Wall at Abutment
Order Number: 1770
#1
Number of
Client: City of Coppell
Specimens: 5
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH
TEST
LAB NO: 152587
Material: Concrete
Test Method: See Below
TEST RESULTS
Report No: 152587
Page 1 of 1
Maximum
Compressive
Average
Spec Age Tested Diameter
Area Load
Cure
Strength
Strength Tested
Nbr (date : days) (in)
(in 2) (Ibs) Break Type
Loc
(PSI)
(PSI) By Comments
A 10/07/13: 4 6.00
28.27 77,425 Type 3
Lab
2,740
2,740
B 10/10/13: 7 6.00
28.27 106,480 Type 3
Lab
3,770
C 10/10/13: 7 6.00
28.27 108,410 Type 3
Lab
3,830
3,800
D 10/31113: 28 6.00
28.27 135,200 Type 3
Lab
4,780
E 10/31/13: 28 6.00
28.27 136,210 Type 3
Lab
4,820
4,800
Type 1 Type 2 Type 3
Type 4
Type 5
Type 6
Specification
Strength: 3,600 psi @ 28 days
Slump: 3 -5
Air Content: 3 -6
Date Received:
10/04/2013
Curing Method:
Standard
Time Sampled:
2:00 pm
Time Batched:
1:19 pm
Temp.: Ambient:
85 °F Mix: 84 °F
CONFORMS
Slump: 6.0 Inches Transported By: LMC
Air Content: 4.8% Source /Sampled At: Truck/ Center
Mix Code: 5409 Plant: 95
Truck /Ticket No: 7026 / 63076209
Quantity Represented: 9 cu. yds. at 9 cu. yds. placed of a 18 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
ell—
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.