Acct ID: 1770 File No: C13 -0634 Date Sampled: 11/02/2013
Report Date: 11/04/2013 Sampled By: Steve Whitney
Project: West Sandy Lake Road By Order Of:
Location: Concrete on bridge slab; Rebar Inspection Order Number: 1770
Client: City of Coppell
REPORT: Reinforcing Steel Inspection LAB NO: 153916 -1
TEST RESULTS Report No: 153916 -1
Page 1 of 1
On the basis of our visual inspection, the reinforcing steel placement meets the requirements of the project plans and
specifications.
• Other: Bridge deck Cottonwood Creek westbound lanes
• DRAWING DATE: 3 -28 -13
• DETAILS REFERENCED: #4 Bars on bottom and #5 bars on top, #4 OC at 6" and #5 bars OC at 9"
Sheet #85 median edge #4 bars, 2 -L bars at 18" OC
Double mat on expansion joints #4 bars on 4" OC
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group