ST9902-SP131119
MELS ELECTRIC, LP LETTER OF TRANSMITTAL DATE: 11/19/13 REFERENCE: SUBMITTALS TO: Tiseo Paving West Sandy Lake BY: Johnny Heine ATTACHED PLEASE FIND SUBMITTAL SHEETS ON: ITEM DESCRIPTION 1 Additional Submittals THESE ITEMS ARE SUBMITTED FOR: APPROVAL x APPROVAL AS SUBMITTED RESUBMIT COPIES AS REQUESTED APPROVAL AS NOTED SUBMIT_Electronic Copy REVIEW/COMMENT RETURNED FOR CORRECTIONS RETURN _1_COPY REMARKS: 6305 South IH 45, PO Box 40, Wilmer, TX 75172 972-441-6208 OFFICE; 972-441-6394 FAX CONSTRUCTION CONTRACT SUBMITTALS FOR: West Sandy Lake City of Coppell SUBMITTED TO: Tiseo Paving November 19, 2013 SUBMITTED BY: MELS ELECTRIC, L.P. Color Chip for Poles Navigator Pushbutton EZ Comm NAVIGATOR 2-Wire ORDER FORM 1. MODEL 2. SIZE 3. FACE PLATE 4. BRAILLE 5. SPECIAL VOICE MESSAGE 6.COLOR OF FRAME XXX X X X X - X POSITION OPTION CHOICE 1 EN2 = NAVIGATOR EZ Comm(Push Button Station) EN2 2 5 = 5"X 7 3/4" SIGN SIZE 9 = 9"X 12"SIGN SIZE(additional charge) 3 3 = 9"X15"SIGN SIZE(additional charge) 3 0 = NO SIGN(-$5.00 price reduction) A = OPTION"A"(International Walking Sign,Black on White)5X7&9X12 ONLY B = OPTION`B"(Informational Sign)5X7&9X12 ONLY 0 C = OPTION"C"(9x12 Countdown Sign)9X12&9X15 ONLY D = OPTION"D"(International Walking Sign,White on Black)5X7&9X12 ONLY 4 N = NO BRAILLE B B = BRAILLE TEXT(Additional charge. Provide details on page 2.) 5 0 = STANDARD MESSAGES 1 = SPECIAL VOICE MESSAGE(Additional charge. Provide details on page 2.) 6 B =BLACK G =GREEN Y = YELLOW (On all units,the base is BLACK,-B-Y-G is LID color only) PG= SOLID GREEN(Additional charge) PY= SOLID YELLOW(Additional charge) EZ Navigator Part number = EN23OB1-B Total Qty of Ped Stations: CONTROL BOARD CCU2EN (Central Control Unit)One required for each intersection Qty: ECONFIG(Configurator) If not needed,enter 0 for qty. Qty: Special Button Designators Units can be ordered with Bi-Directional(double)arrows or no arrow on the button. If one of these is what you want to order add one of the following after the color designator. ❑-BD for Bi-Directional(double)arrow ❑-NA for No Arrow ❑-WRT, for Wood Pole Mount,Conduit hole on Right side,threaded ❑-WTT,for Wood Pole Mount,Conduit hole on Top,threaded ❑-WPC for Pole Cap ❑-ES for External Speaker option ❑-EB for External Button Voice Message Delivery Options: Special message Recording per Crossing Qty: Special Message Flash Drive Qty: I I Special Message Email Email Address to Send Messages to: Custom Voice Message Details (Fill out one form per intersection) Voice on Location and Walk Message(s)& Braille. Please give phonetic pronunciation on difficult street names so that we record them properly. Please note that unless Street,Drive,Avenue,etc...are necessary for intersection identification,it is recommended to leave them off. Qty VOL: Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE Qty VOL: Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE Qty VOL: Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE Qty VOL: Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE Qty [ VOL: Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE Qty VOL:Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross I (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE Qty VOL: Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE Qty VOL: Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE Qty VOL: Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE Qty VOL: Wait to Cross at Wait (Street Being Crossed) (Intersecting Street) Walk Message: Walk sign is on to cross (Street Being Crossed) (Street Being Crossed) Arrow Direction(R/L) Street Name in BRAILLE . ., ., „ k, ..I.!.. . , Navigator4APS' - Comm (thicãtor .,r The ext generation o PS ro/ ti, . . a 5 r � ,,±31.4:-.,-:=41i44...--7, _,.. . -- - N A is = s- f? Your APS information should c:,,_ e ,--. 4 ag be accessible to you!! ! „ S1ART CROSSING if Watch For ,.. �A .. dos #- ., 91�°�.- .f. '� it Vehicles " "9 f1, 'fc i ' - .,-mot" ®.. l DON'T START ` of — 9 — Finish Crossing t cx If Started /FLO M \ —— STEADY .. _F, 11 DON'T CROSS .�'�: TO CROSS ' i, 41 AA PUSH BUTTON . APS provides multiple sources of information at the crosswalk for all pedestrians... ,, Now secured Ethernet access provided so you • 0 •1 can manage,maintain and control your APS systems. (to ‘ EZ Communicator is a fully integrated Accessible Pedestrian System. It offers (' i multiple audible indications and a vibro-tactile indication to clearly identify to ALL Pedestrians the information needed to Navigate a crosswalk. l User.Benefits: Ambient noise controlled locator tone,easy to activate 2"ADA button with a raised arrow,high quality digital audio messages with automatic volume adjustment to ambi- _ 9 q Y 9' 9 J "' '`, 1 ent noise levels as well as vibro-tactile walk phase indication. Meets&exceeds ADA, C) A z MUTCD,TAC&PROWAAC guidelines t`r 4' Agency Benefits; l' • Backward compatible with the Navigator 2-Wire System • Easy Installation(no need to open front of unit) • Easy maintenance and changes-Sounds,Voices and Software can now be uploaded via secure USB port at the push button station 3 • Multiple ways to program,configure and save settings(Configurator,Laptop ,nstaller/Technician access the at Cabinet,&more coming!) a.,m at the intersection va..•. • Multiple ways to easily access status and condition of installed equipment �1 , - • Independent Lab tested to meet T52 and NEMA requirements-ensures you get i 4 / the most robust design on the market 0 ,� • Unmatched Digital Audio Quality ■ a ;: • Several levels of Conflict Monitoring to prevent false walk indications Configurator Laptop .., _ POVIVA a Setting A:Hiaher Standard 380-OQZA Full ADA, MUTCD 2009 and TAC Compliant Backward Compatible with existing Navigator 2-Wire System Operating Specifications Design Compliance Parameter Rating Test Type Compliance Backward Compatible Full compatibility with Navigator Functionality MUTCD 2003—4E 2-wire System Products Temperature and Humidity NEMA TS 2 _Operating Modes EN2(EZComm)or N2(Navigator) 120 VAC at the cabinet for Transient Voltage Protection NEMA TS 2 the system. Transient Suppression IEC 61000-4-4,IEC 610004-5 Operating Voltage PBS operates off of 18-22 DC Electronic Noise FCC Title 47,Part 15,Class A [ from the CCU2EN. • Mechanical Shock and Vibration NEMA TS 2 j Maximum Number of 16 ADA Compliant Push Button Pedestrian Stations Stations per EN2 CCU2EN Enclosure NEMA 250—Type 1 Operating Temperature Range -34°C to+74°C(-30°F to+165°F) PSM2 Enclosure NEMA 250—Type 1 Storage Temperature Range -45°C to+85°C(-50°F to+185°F) PBS Enclosure NEMA 250—Type 4X Operating Force 3.0 lbs Maximum Electrical Reliability NEMA TS 4 MTBF—CCU2 2,000,000 hours Notes: - 1)Applicable sections only of referenced standards. MTBF PSM2 2,500,000 hours 2)Specifications subject to change without notification. - 3)All specifications are Typical unless otherwise specified. _MTBF—EN2(PBS) 3,000,000 hours 4)Units meet all specifications when shipped from the factory. Switch Operating Life Greater than 20 Million Operations Audio File Updates Vla Secure USB Port Microcode Updates Via Secure USB Port Sound Synchronization All Sounds are Synchronized All the great features of the Industry Leading Maximum Volume 100 dB @ 1m Navigator 2-Wire Systems,with... a Automatically Adjusts to Ambient Automatic Volume Range Over a 60 dB Range • Up to 16 Pedestrian Push Button Stations(EPBS){EN2 Mode) Volume Over Ambient Adjustable up to 10 dB • PBS Enclosure rated NEMA 250—4X Minimum Ambient Sound 37 dBA Locate Tone Volume Adjustable from-24dB to+6dB • High quality pure Digital Audio Ambient Audio Quality 2%Total-Harmonic-Distortion • Built-in Push Button Conflict Monitoring Plus Noise @ 1 kHz Supports Additional Buttons for • Health Check of all PBS every 30 seconds External Button Input Bicycles or Horse Crossings (-EB Option) • Ethernet access to PBS Configuration and Health Check results Second Audio Output Supports Beaconing or E Ping-Pong(-ES Option) • Ethernet setting of PBS Configuration False Walk Detection Built-in—Four Independent Checks Ethernet access has password protection Event Monitoring Built-in—PBS Health Check Every g 30 Seconds with Fault Recording 101100BASE-T,Built-in Server Host • Easier to install. Easier to maintain. Ethernet interlace with Password Protection Mutes Entire Intersection Except • Easy access to all terminals without un-Mounting PBS's Extended Push Priority the Selected Crosswalk • Firmware/Audio Updates via Built-in Secure USB Port Extended Push 0 to 6 Seconds in 0.5 Second Steps Multiple Languages Maximum of Two Languages • Single field replaceable internal module on Push Button Station Selected via Extended Push Intersection Broadcast All PBS Simultaneously • Wide Operating Temperature Range of-34°C to 74°C Broadcast Special Message -- "R -- Wide Storage Temperature Range of-45°C to+85°' • Full NEMA TS 2 Compliant • Full NEMA T5 4 Reliability • Independent Hardware Push Button Pedestrian Conflict Monitoring with PSM2 PQIRAwww.Polara.com • * E 8 m `m c m , a) N "' 9 m CO -c 0 a@ .c —c Y 3 U a - c .c o in d -c - c m s o r N Z c '- '. '5 N a 70 .^O N . -O T O CD U N c°i N c_ > a) . Z ° c n w 8 3 c c 0 2 a s •E Lii Q o, w . a) •N E -a w 3 a) m cm E o o c E � v Q h c ° c• ) a E a) co c N .21 5 c O a ° p a ° c v8 a _ j ifltll1 C U • N 2 ° m iU @ a , Ca V d O LI m c a •y a u c c> m O O U > o a)co m U c • E --b..> N V . O • c O w 0 c U Q as ° > ... ca C m O p 0 O > • O c 7 O .- N N c W N N 'a O 2 > °- O ( E c c ° U ' a c c E co o > aa Ego o am s a ca a rn c o c Y ' ° E ' c i E a m °' O o >7 CO Y E a) o c :. 3 c U c 7 b o E € O O@ S U 6 ° E c --5 r) d V - O N E E E a c c) (0 T N L o O c U) S - 7 C -0 C -p _ to CJ o L m e) 0 .0 a O Q N o � . N W c CO c E O a) - ( N coQO E ca O L p c 2 ° N Q o 7 = ° s a)E) .5 12 0) > c) E E -° c .(7) E m cn e oc ° rn m , d c) c E z '§ s m .S ° = cn m m Z 8 m v . E a O E _ •N c E ai .c? n 0 a • o ) O - c O c -6 c >, C N O > 6.-', o . p O — Z U w N N E - D O t o . c a) O N c c O E - ° o o E c ° > c U CO U c ca) 't N v o o U c 3 ° m o o ' c O a) ° c N a) m ° a) Q 7" -8 •- - t a) m e 0) .- E > c V a w d a) - O N O c '> C z v V > E Q c c ° O C C c g E E c E c T C « . O y N ° O " m G m .-0 a D c Co 0 O V t 7 a -8_ > * U O a 3 a o o o U N .Q v m -o ) cn . 12 ' = c E `T o E fn m e . tii c °O v a 2 c m °m °a '- Z n •c 0 at 00 11 ! HiUH )C W _Li) (al o W J 0 c - U b q U v CO C.) a Q W a) U a) U it 5 H Jo m 0 � V t ° m D m Z II - .2 O. W H a a d .c s m W . . . . . . . . . . . . .m . L 5 .— \ \t,'-.,.,-..-..1 r.,,.„..i.,;„,,,,,-.,,,,,,,,qi,1i:2;27;;;;;A:4--,,,-;,:...4 .,y;.,,;:::,;,:,,:j.':,:47.11,4.1,':0 .,•., ••-,, -.",''-':''.:T'ZL.44g4V,.,Qk!,p,,--,,''-;.---':- , ill f yy .4,,, ,., a �I,4,t,a� Vie. A ti lIp KAI J aG 4 E t x'°F1 1 4( .S f" ! q{ tl�l 'M Al.N �S 9 .S �I rr< N S .0' '� P � r a�� Jq if i y� "C.pap �i a y,+_r a•• O �O�I ;� � ` t 1 0J iaig -` „� v) Z (0 ,,,!,..:,le 514 l9 0, @ r,;1 1, J I% .�- �j; 3 - 'W .' '1�'r� l�'a ��4� ' " m a• ICI C ... Z `. � lT u 1 t H 0i ( � �t , i�` - J _ L ., v � �n,, qIl i� 1 i �� 0" � il �I -,-, m c 0 � l a � f � r � W 0 N D Fri V :a Z N W v f9 w r Px U d 0 � LTU 4 l;:;i,Jitc'i:i"',L,.;.:Ait(;:tliiictii'llrIIIIII16:i1V''L--.--.t.ii1114. i I ti ° C C W U ip �"3 3 CI `m o 0 O _ o Q N E U U l0 0 d O w V 5 • w fp-0 m a)p T a 'CC F°- C C O C O 0 C CO O CD a) O C C N CA 22 o Q O C O 0 • 7 7 _ - Y C N 7 C 0 C2 0 0 0 C c m o UU Ucnm 3)in� N - 3 v-o 0 c 2 E C 'O.O 0 C C J a) ch M M U5 a) a) f0 D i ) - c a O N N N L N Y a) N - a) O_ O O_N p C C Q '- Z m a) 1-1- 2 3 W W o C c c m o) 08 m c LY � o N - p n .o C p p •- co o o a 0 0 0•} c c c I I 0_ I I 0 I I I T° LL W a3 Lg LL a) H H FU- E o) m - ° o1-F- mU as W e 0 C o » > �� rn W - 5 a 0 O co ld p m 0 m 0 Z co 1 m Z m 5 = o Z (4 1 U a) as N 0 % go9aa o p "' 0>- 2CD0 o f° o 0 0 0 ' CO CO m I I Z m O_Cl•O.•O.N C O' I cso � • I I - DODO - a Nis,- E et Z c0 ml amUOO u. ...x x x E0 LL ,,_ to o) a) LLN I I I W cN n 01 N LO a)) CO 1 g co ZI z al I > w 65- 01 z m N m ZI rn W 0 0 Q Z O c T OV - - I N Y a) 'NO aa)) 0) F O) a) D E 0 C C (-.1_ C m N `0:1) c° go o ° + a m ID W In CO (d Zr. a N E N = N C H CO a) I 1- 0 O a) N a) N N N .. t t Q Y co 3 E j, 0 N F) "� O O 0 O V O N 7 0 a) w 0 o CO © l0 E N a w o c0 O = d 0 X id m 3 .2 c d y Z " „ m O WV - co a) o el (5 ( o o w o a C�h ° O E o c c N N rn �� a �> ° o p > N 1� co (6 r 7 r L?,. p N CN 1 v. CN V t C C N p O o`o sl z_o 0 2 0 N m a O '= 0 CNI CO co 1- 1- O_ 1- N F- v) E o) ° N 0 U U O "� m = U a a I- a a a a9i O N - C H m W i+t+? o c) O N O - o E 1- 2 5 ,, U 2 5 2 ��-' c " °c m a m W O O O M U 2 Z Z w L L L Z Z Z § .. 0 N o c• a vow 3 v o 0 o Z mot - _ v ��j U) N 3 N 4- C cp a) a) W 4 o 003 rn N 'O tU O f0 U O [C c 0 c � 12 s o_ a 3 N N W C) o CO CO 0 =p 0 m ° s Z a) N N N O W , r mTi Tr., N U N U O N C N �F N O 0 °n a N D a) vi _c 3 O _ 0 N .,j t N co CA 0 C U 0 N U N ° m a~i O U c) C W w c Q a o c 3 N Q °) n N o p `m `m m n y o .3 a Cl) E Q '- N O n E C O co C = co o N c • c N c CD tl7 W N > E G j (n Z W 0 H s `° a) c °- o I Is rn H m a a , V Q. •s a E aa) $ o E S O = S N cC o o 8 as v Y =m . 5 c O■ O Q Q �O Q co •3 N C j •� N j N N N a) a) _a Z a) d N M N E O o. L w 3 L a° ^! O (n O t0 a 0 F W F- F- F- W > W W t FL- 0 m n. °/ o °c ° ao E 0 U l0 a w U c c w LO-. O O O a) N `m co O N — 'd Vl a CL Ic 3 ' Z 819 a) >uco N N C O U N 3 U 3 ) o co co O I° . •a v O O N N L c. N d N C .-. E L U co U c '_ m O m L m c Z O O a 3 d>. C 7 W o o V N a m L m N E N - c•3 .o) c a •c O N U o a 3 ° 0° o 0 O C O CO 7 N p c m Z g c a)N 17)0.N c m Z a) 4° c F- O a) > N w a) O m cc a W a c _ c C O D - 3 N E O a) a3• •y 3 a ° Q E a o m U aai• 'o v) Q < o Q_ o 7 a .N.. C a) = CO a) N N .0 X fn I— c m o a ° Q ° 0) cp o w '� �° o E U a W (° Q 01 0 o N O Q) CO O ° C v°i 0 N Q 0 N V _ z O N O C ' c CO y Q C U > a 0 O C o co N N ° In -- I.L tk Z O N p) O N o a) Z O S •o L O N U Y N 0 O C W �.r N N ii p c° p ° X p > •9 m U HhH c c U a U u� E_ E U N o ° O t< U N N U ¢C 3 N W c C J O U p co + co W c • ° U 0 U° o) c $ a 0 E •3 vi o oc a�°i C) Q U c CO Y o + = m N O C� V a C c N U N m N U W CO N o 7 V u O U m ° c p) a) _ o N c a Z CO 7 > N U ° 0 a o LL N 06 V O Y C O 7 N N '• a N a) N 7 °" O CD LI- m O w U Ci O C U m N N U Q �I C 3 O W a O c W co N N p O '•' v O E- •'° > � S o m Y• c c O in H H I ! I C C rL/1 �° O L O O .L-. a N N a-, p N N• U 0 w cfi w -CI c CO 2 �°O N a) m u) O. d o y H o Q o � m o) I.-- Z HIIIH ! Z a V a° voi co U c.U m o X C U a) Q) C a) 3 N co _O a a = m C > • IL = O X N O N m a L m O L N Z j L a) a) (° N c c 1- E a) m E w v o F- a E H c W N 1- c d d LL Q 0 W 0) O Z Z O ��� O J U QN \_� cc Id. ~ 0) Z l0• W s C.7• IX \ co O • H o Q N O g U M W Z N cc W4 M E J{ \�\\\\\11 Z CD Z M ' ® gA \ I—I .0000 0 00 0 03 + a•11111; 4` z U 0000 0 00 0 OL mmk �'�\ N o^ / v W U m00000000 „ V o� 4 N a 0000 0 00 0 0 li: 1 € l�l� ■ o UJ -—E t E g [ I',. WWI..PIOUDINNO5 1/1,1150 ® B lIOJ SNp1N11L5N1 N011Y1'IV15Nl 335 V C O C C N C N _ w Ing O 0 a CIL o O ITT (.k)bal Traffic Technologies — • OpticomTM Infrared System Opticom' Model 138 Detector Cable Description Opticom'"Model 138 Detector Cable is designed and manufactured explicitly for use with Opticom'"Detectors.Opticom model 138 has three color-coded conductors,a conductive shield and drain,and a black PVC jacket. "` ` ° � �i This durable,high-quality cable carries the `� appropriate power to the detector from the Opticom'" Phase Selector and delivers the ' � necessary quality signal to the phase selector discriminator circuitry up to 1,000 feet(305 m). °� ' Features and Benefits • Optimized to interface Opticom detectors to Opticom phase selectors or Opticom 0pticom"Model 138 Detector Cable isi 0.3 in. (7.62 mm)in Discriminators diameter and is suitable for direct burial as well as in conduit and exposed overhead installation.* • Ensures effective range of 2,500 feet (760 m) with Opticom Infrared System components • Durable construction Physical Dimensions —Suitable for direct burial • Outside diameter:0.3 in. (7.62 mm) —Suitable for conduit and mast arm pull • Weight: 0.04 lbs./ft. (65.5 g/m) —Suitable for exposed overhead installation* • Available in: ft., 1,0 , fd 5,000 500 ft. (100 52 mft.,,2 305 500 m,t.760 an m and 15,200 m) spools Operating Parameters • 600 volt rating • 75°C (167° F)temperature range • Three-conductor AWG#20 (7x28) stranded, individually tinned copper:yellow, blue and orange • Aluminized polyester shield with 20%overlap • Drain AWG#20(7x28) stranded, individually tinned copper • Controlled electrical characteristics *Separate messenger wire required Important Notice to Purchaser: EXCEPT FOR THE LIMITED WARRANTIES SET FORTH IN THIS DOCUMENT,GLOBAL TRAFFIC TECHNOLOGIES(GTT)MAKES NO OTHER WARRANTIES AND EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES,WHETHER EXPRESS OR IMPLIED, INCLUDING,WITHOUT LIMITATION,ANY WARRANTY AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. GTT will,at its sole option,repair, replace or refund any amounts paid for any Opticom TM Infrared System component found to be defective in materials or manufacture within five(5)years from the date of shipment from GTT.See"Warranty and Extended Coverage"for details and limitations of the coverage plan.GU will provide a functioning replacement component at a standard charge per unit for an additional five(5)years. GU warrants future system operability coverage as described herein.The warranties set forth in this document shall not apply to(A)incandescent lamps(confirmation lights)or(B)any Opticom infrared system components which have been (1) repaired or modified by persons not authorized by GTT;(2)subjected to incorrect installation,misuse,neglect or accident;(3)damaged by extreme atmospheric or weather-related conditions;or(4)subjected to events or use outside the normal or anticipated course. IN NO EVENT SHALL GTT BE LIABLE FOR ANY INJURY(INCLUDING,WITHOUT LIMITATION,PERSONAL INJURY),DEATH, LOSS,OR DAMAGE(INCLUDING,WITHOUT LIMITATION,PROPERTY DAMAGE),WHETHER DIRECT, INDIRECT, INCIDENTAL, SPECIAL,CONSEQUENTIAL OR OTHERWISE,ARISING OUT OF THE USE OR INABILITY TO USE, REPAIR OR FAILURE TO REPAIR,ANY GTT PRODUCT,REGARDLESS OF THE LEGAL THEORY ASSERTED.THE REMEDIES SET FORTH IN THIS DOCUMENT ARE EXCLUSIVE. Sale and use of the Opticom infrared system is expressly restricted to authorized agencies of government customers,within their specific jurisdictions.However,because the infrared signal generated by the Opticom infrared system is not exclusive, GTT does not warrant exclusive activation by purchaser.Authorized users who desire to use or coordinate use of the Opticom infrared system with that of other jurisdictions must first obtain the prior written approval of each authorized user in the jurisdiction where use is sought. I� Gloli al Traffic Opticom is a trademark of Global Traffic Global Traffic Technologies,LLC Technologies,LLC. 7800 Third Street North Global Traffic Technologies Canada,Inc. Used under license in Canada. St.Paul,Minnesota 55128-5441 157 Adelaide Street West Please recycle.Printed in U.S.A. 1-800-258-4610 Suite 448 ©Global Traffic Technologies,LLC 2007 651-789-7333 Toronto,ON M5H 4E7 All rights reserved. www.gtt.com 1-800-258-4610 75-0500-4553-5(A) I TT Global Traffic Technologies TM opticom Infra System opticomTM Models 711, 721 red and 722 Detectors iFtJp a t ! VI Description The Opticom'" 700 Series Detectors transform the optical energy detected from an approaching, vehicle-mounted Opticom'"' Emitter to an electrical signal. The electrical I g fit. " & signal is transmitted along a cable to the z $ $.41::1 ° _ 1 $ _ Opticom- Phase Selector or Opticom- g ifiz Discriminator for processing. t f i fil414' . i tits �# ' , Opticom 700 series detectors are mounted at ii iii °ii=° " 'It'a roaches. O ticom detectors ma beit mounted on span wire, mast arm or other • `°' ' ,:4� appropriate structures. Opticom'"Models 722, 721 (back)and 711 Detectors Opticom'" Models 711, 721 and 722 Detectors offer significant advances and flexibility for specific intersection applications.The Features Opticom detectors are designed for common • Advanced electrical transient immunity applications in three configurations: one • Modular design direction—the single channel Opticom model 711; the single channel, dual detection • Adjustable turret configuration: Opticom model 721; and two direction, two accommodates skewed approaches output detection—the dual channel Opticom • Lightweight, durable, high-impact model 722. All Opticom 700 series detectors polycarbonate enclosure greatly reduce installation and life cycle costs through their modular design, adjustable • Simplified installation: span wire or tubes, and compatibility with existing mast arm Opticom'" Infrared System intersection and • Gray door identification of Opticom vehicle equipment. model 722 1 t £ ry 1 .p Opticom"Span Wire Clamp Opticom'"Model 138 Detector Cable Accessories Physical Dimensions • Opticom" Span Wire Clamp Opticom" Model 711 Detector • Opticom" Model 138 Detector Cable Length: 12.0 in. (30.5 cm) Width: 4.75 in. (12.1 cm) Operating Parameters Height: 5.63 in. (14.3 cm) Weight: 0.88 lbs. (400 g) • Reception Range:200 ft. (60 m) adjustable up to 2,500 ft. (760 m) Opticom'" Models 721 and 722 Detectors • Electrical:24 to 28 VDC, 50 MA minimum Length: 12.0 in. (30.5 cm) • Temperature Range: -30° F (-34° C) to 165° F Width: 4.75 in. (12.1 cm) (74° C) Height: 7.13 in. (18.1 cm) • Humidity: 5% to 95% relative Weight: 1.12 lbs. (508 g) Important Notice to Purchaser: EXCEPT FOR THE LIMITED WARRANTIES SET FORTH IN THIS DOCUMENT,GLOBAL TRAFFIC TECHNOLOGIES(GTT)MAKES NO OTHER WARRANTIES AND EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES,WHETHER EXPRESS OR IMPLIED, INCLUDING,WITHOUT LIMITATION,ANY WARRANTY AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. GTT will,at its sole option, repair,replace or refund any amounts paid for any OpticomTM Infrared System component found to be defective in materials or manufacture within five(5)years from the date of shipment from GTT.See"Warranty and Extended Coverage"for details and limitations of the coverage plan.GTT will provide a functioning replacement component at a standard charge per unit for an additional five(5)years. GU warrants future system operability coverage as described herein.The warranties set forth in this document shall not apply to(A) incandescent lamps(confirmation lights)or(B)any Opticom infrared system components which have been (1) repaired or modified by persons not authorized by GTT;(2)subjected to incorrect installation,misuse,neglect or accident;(3)damaged by extreme atmospheric or weather-related conditions;or(4)subjected to events or use outside the normal or anticipated course. IN NO EVENT SHALL GU BE LIABLE FOR ANY INJURY(INCLUDING,WITHOUT LIMITATION,PERSONAL INJURY),DEATH, LOSS,OR DAMAGE(INCLUDING,WITHOUT LIMITATION,PROPERTY DAMAGE),WHETHER DIRECT, INDIRECT, INCIDENTAL, SPECIAL,CONSEQUENTIAL OR OTHERWISE,ARISING OUT OF THE USE OR INABILITY TO USE,REPAIR OR FAILURE TO REPAIR,ANY GU PRODUCT,REGARDLESS OF THE LEGAL THEORY ASSERTED.THE REMEDIES SET FORTH IN THIS DOCUMENT ARE EXCLUSIVE. Sale and use of the Opticom infrared system is expressly restricted to authorized agencies of government customers,within their specific jurisdictions.However,because the infrared signal generated by the Opticom infrared system is not exclusive, GTT does not warrant exclusive activation by purchaser.Authorized users who desire to use or coordinate use of the Opticom infrared system with that of other jurisdictions must first obtain the prior written approval of each authorized user in the jurisdiction where use is sought. AS' Global Traffic .c_. Tec:hnolooies Opticom is a trademark of Global Traffic Global Traffic Technologies,LLC Technologies,LLC. 7800 Third Street North Global Traffic Technologies Canada,Inc. Used under license in Canada. St.Paul,Minnesota 55128-5441 157 Adelaide Street West Please recycle.Printed in U.S.A. 1-800-258-4610 Suite 448 ©Global Traffic Technologies,LLC 2007 651-789-7333 Ca'ON M5H 4E7 Canada All rights reserved. www.gtt.com 1-800-258-4610 75-0500-1682-5(A) Opticom OPTICOMTM PRIORITY CONTROL SYSTEM OPTICONPLIVIODEL 764,IVIULTIMODE PHASE SEL . . OPTICOM''SYSTEM COMPONENT FOR ENVIRONMENTS WITH INFRARED AND GPS TECHNOLOGY Description a,F The Opticom" Model 764 Multimode Phase Selector is a plug-in,four-channel,dual-priority,multimode encoded signal device designed for use with both Opticom'"infrared system emitters and detectors and 0pticom'"GPS radio/GPS intersection units and vehicle equipment.It can be installed directly into the input files ,,rCia of Type 170 traffic controllers equipped with priority phase selection software and in virtually any other traffic H6 „ controller equipped with priority phase selection inputs and related software.Phase selectors are powered from AC mains or 24 VDC and contain their own internal power supply to support 0pticomT”infrared system detectors , and 0pticom'"GPS radio/GPS units. ,,i " The 0pticom'Model 764 may be used in IR only applications,GPS only applications,or IR and GPS applications simultaneously. The 0pticom" Model 760 Card Rack is required when input file space is not available.When used in GPS only mode,the Model 1040 card rack may also be used. 0pticom"Model 764 recognizes and discriminates among three distinct Opticom'"IR emitter frequency rates via 0pticom'"detectors:high priority,low priority and probe priority.Within each of these three frequency rates, the phase selectors further discriminate among 10 classes of vehicle identification codes,with 1,000 individual vehicle codes per class—10,000 total per frequency rate.The Opticom'"Model 764 also recognizes three different priority levels transmitted by Opticom"GPS vehicle equipment:high priority,low priority and probe priority.Within each of these three priority levels,the phase selectors further discriminate among 254 agency IDs,15 classes of vehicle identification codes,with 10,000 individual vehicle codes per class—for more than 38 million total per priority level. Opticom" Model 764 Phase Selector internally records each system activation.Each entry contains: •Intersection name •Final green signal indications displayed at the end • Date and time of the activity of the call •Vehicle class code of the activating vehicle •Time spent in the final greens •Activating vehicle's ID number •Duration of the activation •Agency ID(GPS only) •If preempt has been requested and reason if not •Channel called •Turn signal status at the end of the call(GPS only) Global Traffic Technologies,LLC •Priority of the activity •Entry,exit and average speed(GPS only) (GT1),formed in 2007 from •Relative priority level 3M's pioneering Intelligent Transportation Systems business, is the manufacturer of Opticom'" priority control systems and Canoga'"traffic sensing systems. /� Building critical ,,ITT traffic connections- OPTICOMTM MODEL 764 MULTIMODE PHASE SELECTOR • OPTICOM''`SYSTEM COMPONENT FOR ENVIRONMENTS WITH INFRARED AND CPS TECHNOLOGY Features Accessories •IR only operation,GPS only operation,or simultaneous •On-site Interface software package IR and GPS operation •Model 768 Auxiliary Interface Panel •Four channels of detection •Opticom'"Model 755 Four-Channel Adapter Card(optional) •Two auxiliary detectors per channel(IR) •760 Card Rack •Records green signal displayed at end of preemption •Compatible with encoded signal and non-encoded signal Opticom'" Operating Parameters IR Emitters •Four dual-priority and probe frequency channels •High and low priority as well as probe frequency discrimination •"First-come,first-served"for vehicles with the same priority level •"First-come,first-served"priority within each priority level (high or low) •Priority-by-class setting via the interface software •Priority override:always higher over lower •Priority-by-direction setting via the interface software •Opticom—GPS Radio/GPS Unit input •Direct installation into CANNY Type 170 input files •Opticom-Infrared System Detector input(s):one per channel on •Automatic range setting using an encoded emitter(IR) the card edge connector and two auxiliary per channel through the •Call bridging for both IR and GPS calls including mixed mode Model 768 auxiliary interface panel •Low-priority output may be configured for first-come,first-served •Optional interface software for flexible programming options and or all-channel active call history •User-adjustable range setting up to 2,500 feet of operation •LED indicators •Compatible with most traffic controllers -Status •10/100Mb Ethernet communication on the front panel -Radio(GPS mode) •USB 2.0 communication on the front panel -Link(GPS mode) •RS232 communications front port,and rear backplane and -High signaVcall per channel Auxiliary Interface Panel -Low signaVcall per channel •User-selected communications baud rate of 1,200 to 230,400 bits -Two-digit status display per second •Two character display and keypad to enable diagnostics and test •Customizable ID code validation calls to each channel •Flexible programming options for priority control parameters •Voltage:89 to 135 VAC,60 Hz at up to 500mA or 24 VDC at up to •Detailed current Opticom"System parameter information 1 Amp •History log of most recent Opticom- infrared and GPS system •Temperature:-37°C to+74°C(-34.6°F to+165.2°F) activities(10,000 entries) •Humidity:5%to 95%relative •30,000 frequency/class/vehicle code ID combinations(IR) •CE certified •More than 38 million agency/class/vehicle code combinations •NEMA TS-2 compliance (GPS) •FCC compliance •Front panel switches and diagnostic indicators for testing •Accurate infrared signal recognition circuitry Physical Dimensions •Precise output pulse Length:7.0 in.(17.8 cm)x 8.2 in.(20.8 cm)including handle Building critical •Definitive call verification Width:2.3 in.(5.8 cm) TT traffic connections''' •Regulated detector power supply(IR) Height:4.5 in.(11.4 cm) •Optically isolated outputs Weight:0.60 lbs.(272 g) •Two character display and keypad to enable diagnostics and test calls to each channel •Display LED Indicators For complete warranty information visit www.gtt.com. Global Traffic Technologies,LLC -High-and low-priority test calls 7800 Third Street North -Reset to default parameters St.Paul,Minnesota 55128-5441 -Range setting 1-800-258-4610 •User-settable range setting by ETA and/or distance(GPS only) 651-789-7333 •Varied outputs depending on turn signal status of requesting www.gtt.com vehicle(GPS only) •Diagnostic test Global Traffic Technologies Canada,Inc. •Advanced built-in diagnostics and testing 157 Adelaide Street West •Tested to NEMA environmental and electrical test specifications Suite 448 Toronto,ON M5H 4E7 Canada 1-800-258-4610 l f Opticom and the GTT logo mark are trademarks of Global Traffic Technologies,LLC.Used under license in Canada.Please recycle.Printed in U.S.A. m Global Traffic Technologies,LLC 2011 All rights reserved. 79-1000-0524-0(B) SOUTHERN MANUFACTURING 10-4%, Division of Accord Industries 4006.4144:4_40` 501 Herndon Ave. Mir Orlando, Cete‘44)'C°1 (407) 894-8851 Ph (407) 894-5373 Fx 4614r., Illuminated Street Name Sign Specifications This specification will provide information concerning the Illuminated Street Name signs manufactured by Southern Manufacturing. 1. Sign Features include • Excellent day and night visibility • Energy efficient/Very Low wattage required for LED • Standard design requires no tools to open sign or replace lens. • Designed to withstand 110 mph wind. • Radiant high temperature fail-safe circuit for LED to prevent premature bum out in extreme temperatures. • IISNS is on FDOT APL and is UL 1.1. Material Each sign body is constructed from 5052 H32 .125" thick aluminum. Single face signs are one piece construction and all seams are continuously welded to ensure a watertight seal. 1/4" holes are incorporated in the bottom of the enclosure to prevent possible buildup of condensation. Double face sign bodies are continuously welded on all seams. The double face sign also features doors on both sides for easy access. 1.1.1 Standard Design (LED and Fluorescent) • 4ft , 6ft and 8ft width (Single and Double Face) • 19 inch height with tapered body depth of 8" to 5 3/8" • 24 inch height with tapered body depth of 9 3/8" to 5 3/8" • Mounting Brackets — Tri-stud on top of sign, but other options are available upon request. 1.1.1.1 Exposed Lens width x height • 4ft x 19"— 44" x 15.125" • 4ft x 24" — 44" x 20.125" • 6ft x 19" — 68" x 15.125" • 6ft x 24"— 68" x 20.125" • 8ft x 19"— 92" x 15.125" • 8ft x 24" — 92" x 20.125" New Release Page 1 of 5 9/10/200 1.1.2 Custom Designs (Single and Double Face) 1.1.2.1 Thin-LED is a smaller version of the standard sign with a thinner profile. (LED Light Engine only) • 4ft, 6ft and 8ft width • 19 inch height with tapered body depth of 6 5/8" to 3 Y4" • Exposed lens height is 14 7/8" • Exposed lens width 4ft—45.5", 6ft— 69.5", 8ft — 93.5" • Mounting Brackets — Pelco SE-438, SE-508, SE-0464, SE- 0371 and AB-0160 w/cable 1.1.2.2 ThinLine is a straight body LED design (LED Light Engine only) • Top and Bottom of sign is extruded aluminum 6061 • Sides are 5052 aluminum .125" thick sheet metal • 4ft, 6ft and 811 width • 22.5inch height with straight body depth of 4 1/2" • Exposed lens height is 18 I/2" • Exposed lens width 4ft—45.75", 6ft — 69.75", 8ft —93.75" • Mounting Brackets — Pelco SE0464, SE-0371 and AB-0160 w/cable 1.1.2.3 Induction sign is a tapered body design (Inductive Fluorescent) • 411, 6ft and 8ft width • 19 inch height with tapered body depth of 11 1/4" to 7 1/4" • Exposed lens height is 14 3/4" • Exposed lens width 4ft 45.25", 6ft — 69.25", 8ft — 93.25" • Mounting Brackets — The induction sign comes with a SE- 0512-M1 Tri-Stud Hanger pre-assembled to the top of the sign body. • Induction sign is not on FDOT APL or UL Listed 1.1.3 All signs use a UL approved neoprene gasket strip to provide a watertight seal between the body, lens and door. 1.1.4 Lenses are impact resistant, .118" thick UL approved white or clear polycarbonate. 1.1.5 Sign film is ultraviolet (UV) resistant and available in GMI or EC. Different sign film colors are available but must be specified at time of order. Diamond Grade backing is also available upon request. 1.1.6 Stainless Steel Hardware Door Latches and Keepers are a turn-lock style device that secures the door to the body which requires no tools to open the sign. Full length continuous piano hinge is used on the door to the body with downward motion for easy of accessibility. New Release Page 2 of 5 9/10/2008 1.1.7 Provision for photoelectric cell mounting is available on all signs. Southern carries Intermatic model K422 IC and Tork 2001 which can control 4 IISNS per intersection, 1.2. Finish The sign bodies and doors are polyester powder coated for durability using a satin black finish to the external aluminum surfaces. Other colors are available and must be specified at time of order. 1.3. Mounting Standard mounting pattern is Tri-stud pattern on top of the sign body. Custom Design signs have specific mounting holes as well as brackets. Other patterns on standard signs can be provided and must be specified at time of order. 2. Electrical 2.1. General Each sign type consists of an electrical/electronics package that is custom designed for its particular application. In general, it consists of a power supply, Light Engine, and fuse. All LED are mounted onto a circuit board which is mount onto a .125" thick aluminum heat sink. Individual Light Engine electrical characteristics LED Inductive Fluorescent I Standard Fluorescent Ballast(P/s)Model 0T75/120-277/24L I I ix100ICE/UNV-T MB2x96/110/12ORS Dimensions 9.5"Lx 1.63"W x 1.18" 11 7.15"Lx 396 W x 1.70-H 11.75 L x3.125 W x2 562 II Input:9"(18AWG solid w ire) Input:connector for 18Awg black& white Connections Output:9" (18AWC solid solid copper. Leads only(no connectors) wire)red &blue Output:2 PM connector Nominal Input Voltage(VAC) 120-277 120-277 120 v Nominal Input Current(Amps) •75@120v/.32 2.56 g120 / 1.06 @277 @,277v 2,05 In ut Watts 90a120 308/298 246 Power Factor CO 120v 0.99 >95% >90% Max Output Power(W) 75w 100 212 Max Line Ripple(V) +-0.2v Na Na Location Rating Dry&Damp Outdoor Outdoor Input Frequency(Hz) 50/60 50/60 60 Ambient Temp Range -25°C through+60°C Starting Temp. -40°C,Temp Starting Temp:-29°C, Max: 65°C Max Case Temp 90°C 65°C UL Class Class 2, UL 1310,UL48 Class P.Typel Class P Type I 2(1 ICE100/BU2P bulb per <=2 F961-10T12 Bulbs per Light Engine(s)(Bulbs)driven <=8 Rebel LED Light strips ballast) Ballast 2.2. LED Light Engine The LED drive current is regulated using a pulse width modulated 24v DC drive and limited to approximately 300ma through the LED chain at normal room 1 Amp and watt figures listed reflect the signs usage. 2 inductive ballast/tube light systems are used per inductive fluorescent signs. Consequently the manufacturer specified amp and watt values for the ballast/tube light system will be 'A of the value listed above. New Release Page 3 of 5 9/10/2008 temperature. This provides for a stable light intensity under varying voltage conditions. LED's within the light engine are series wired for increased efficiency and incorporate fault tolerant design. A LED bypass isolates a failure to that particular LED and will allow the remaining LEDs to operate normally. The constant current regulator will readjust the drive current to prevent overdriving the remaining operable LEDs in the chain. Thermal monitoring provides temperature protection to the LED chain. As the heat sink temperature increases, the LED drive current is reduced along with LED intensity, helping to limit the junction temperature and contributing to the long LED lifespan. The current reduction follows a non-linear curve that is high temperature biased (greatest reduction occurs at the higher temperature). Thermal regulation of the drive current begins at —40°C and continues until a complete shutdown occurs at — 100°C. An onboard display LED indicates when a overheat shutdown is present. Recovery occurs automatically with a reduction in the heat sink temperature. 2.3. AC Loading Matrix for all sign types • Fluorescent Inductive LED WEERMINIEIMIN Double NM Double Sin•le Double Sian Width 4 6 8 4 6 8 4 6 8 n 6 8 4 6 8 4 6 8 # Light 2 2 4 4 6 8 Ens Ines VAC Min / Max 120 120 120 NEM 120 277 Power Freq Hz ileallEta 60 60 50 60 50 60 Engine Temp Deg 50 70 -40 65 -20 60 Am. T •ical 205 1.76 0.2 0.3 03 03 0.5 06 AC Load @ 120v AC • 142.68 211.2 Ill 28 36 36 51 66 3. Photometric Performance The entire surface of the sign lens is illuminated at an average level of four (400) lux 4. Quality Assurance All signs are manufactured in accordance with the Quality Assurance procedures outlined in the Southern Manufacturing Quality Assurance Manual. Upon completion all signs are 100% tested to ensure all light engines are functioning. All signs comply with FDOT standards and are listed on the FDOT APL. Certificate available upon request. All Fluorescent and LED signs are UL listed Electric Sign. New Release Page 4 of 5 9/10/2008 5. Warranty Southern Manufacturing, a division of Accord Industries, provides limited warranty on all IISNS (Illuminated Street Name Signs) for a period of 3years from the date of purchase to be free of defects in materials and workmanship. LED light engine shall carry a 5 year warranty on parts replacement only. Exceptions This warranty does not cover damages caused by improper storage, handling, installation, failure of the sub-contractor to perform, storms, floods, fire, acts of God or other force majeur occurrences that are outside of the specification parameters set forth in this product description. Southern Manufacturing is the sole determiner of the cause of damage and decision when replacement is necessary. Parts in question must be returned to; Southern Manufacturing 501 Herndon Ave. Orlando, Fl 32803 (407) 894-8851 Return Goods Prior to returning any parts, the Customer Service group must be contacted to receive an RMA number which must be displayed on the outside of the package. All packages must be packaged to protect the contents to prevent damage which could affect the quality investigation of the warrant request. New Release Page 5 of 5 9/10/2008 Alpha BBU 817-831-9406 Ph. PARADIGM PO Box 5508 817-831-9407 Fx. Arlington, TX 76005 TRAFFIC SYSTEMS, INC. Submittal Cover Sheet TO: Mel's Electric Service, Inc Reference: CITY OF COPPELL 6305 South IH 45 W. SANDY LAKE RD & SH 121 Wilmer, TX 75172 PER QUOTE#Q15666DJ attn: Johnny Heine ph: 972-441-6208 JOB#: 13-034 fax: 972-441-6394 Submittal Copies: 1 SET PTSI SO#: HFR-165 DATE SLSMN DELIVERY DATE FREIGHT SHIP VIA F.O.B. TERMS CUSTOMER PO# 11/13/2013 DJ 30-45 Days ARO PPD&Allowed Best Way Destination Net 30 011660 ITEM NO. QTY MFG. /CATALOG NO. DESCRIPTION 1 3 ALPHA BATTERY BACK UP SYSTEM, c/o: ALPHA 017-232-31 Novus FXM 2000 SNMP,UPS ALPHA 181-231-10 Alphacell 220GXL 12V Battery ALPHA 026-053-24 S6 Enclosure w/Generator Option,including: ALPHA 020-165-21 Universal Automatic Transfer Switch ALPHA 012-306-21 Alpha Guard 48V Battery Equalizer ALPHA 740-139-26 LED Indicator Light for Alpha Units is\exldata\submttls\HFR165 Mels Elechic,011660(Apprv) Alpha FXM 2000 UPS Module sty %.;;;; � 9 a., . RRYSH6ffi t .. 4. Bm �f.1IFd6A _ �vt Alpha FXM 2000 Full featured, ruggedized UPS provides clean, uninterruptible backup power ensuring your system will remain running during power outages > Wide range Automatic Voltage Regulation without going to batteries saves energy and lengthens battery life, even during periods of surge or sag in the line voltage > External communications via RS-232 port or (optional) Ethernet SNMP interface provides local or remote monitoring and control > Independently programmable and dry contact relays allow tracking and controlling of key functions > Event and alarm logging with time and date stamping simplifies and accelerates troubleshooting > A wide operating temperature range of -40 to 74°C (-40 to 165°F) is suitable for the most extreme operating environments > Temperature compensated battery charging protects batteries from over charging at extreme temperatures, extending the life of the battery White text on blue display improves readability in bright daylight The Alpha FXM uninterruptible power supply(UPS) modules provide clean,reliable power control and management as part of a complete UPS solution. Each model is available in either North American(120V/60Hz)or International (230V/50Hz)variants.Automatic Voltage Regulation(AVR)provides power stability in unpredictable environments and constant voltage during variable power conditions.Temperature compensated battery charging protects batteries from over charging at extreme temperatures,extending battery life. Event and alarm logging with time and date stamping simplifies and accelerates troubleshooting.Control and power connection panels can be rotated for mounting and display in any orientation**for viewing preference. Power module only Output power derates after 50°C for FXM 2000 (120Vac),and after 55°C(230Vac) "The LCD panel on the FXM 650 cannot be rotated. TECHNOLOWEST" Your Power Solutions Partner Via.. TECHNOLOGIES'° Alpha FXM 2000 UPS Module Consult your Alpha representative for P/N configurations >North America Dimensions: Battery string voltage' 48Vdc mm 133H x 394W x 222D Nominal voltage: 120Vac inches 5.22H x 15.5W x 8.75D Nominal frequency Auto sensing Weight 16kg(35lbs) Input: T ., Current 17.5A nominal Voltage: 85 to 150Vac Output: Operating Current 16.7A nominal temperature range`. -40 to 74°C(-40 to 165°F) Voltage regulation: +/-10%over input voltage range Audible noise @ 25°C. 45dBa 1 metre(39in) Power at 50°C• 2000W/VA *120Vac module derates after 50°C 230Vac module derates after 55°C >International 420:27143111110.1.1111115Allintigial6 Battery string voltage' 48Vdc Nominal voltage: 23OVac Typical output voltage THD:<3% Nominal frequency Auto-sensing Typical efficiency >98%(resistive load) Input: Typical transfer time <5ms Current 9.15A nominal Voltage range: 150 to 281 Vac a r" y ,"` Output: Current 8.7A nominal Electrical safety. UL1778,CSA 22.2 No 107.3-03 Voltage regulation +/-10%over input voltage range Marks: cCSA„/CE" Power at 50°C 2000W/VA EMI. Class A FCC/CISPR [EN 50091-2:1995] **CE applies to 230 Vac version only Alpha Technologies Ltd. For more Information visit www.alpha.ca Canada:Burnaby,British Columbia Tel:604 436 5900 Fax:604 436 1233 #0480014-00 Rev C (11/2011) United States:Bellingham,Washington Tel:360 647 2360 Fax:360 671 4936 Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice member Of The Group'" Copyright©2010 Alpha Technologies.All Rights Reserved.Alpha®is a registered trademark of Alpha Technologies. member of The Alpha GroupTrr is a trademark of Alpha Technologies. AlphaCellTM GXL GelCell Batteries ALPHA Atm ALPHA te-414 �� Vic, ALPHA. NEW 195 GXL and 220 GXL: High-performance Silver Alloy for maximum life expectancy Longer runtime for demanding outdoor environments 100% runtime capacity out-of-box – No cycling required Maintenance-free threaded inserts — No periodic retorquing Available with 4 and 5 year full warranties Wide operating temperature range Alpha's standby battery offering incorporates Gel for thermal dissipation to ensure optimal life performance for your particular Broadband,Traffic or Wi-fi application. AlphaCell Batteries provide the longest runtimes and the best longevity in today's demanding outdoor applications and are backed by Alpha's industry- leading, non-prorated hassle-free warranties. Alpha Technologies „ _ r T ;«,L'y AlphaCell General Specifications i9#,! $ 5 "Ss .ar 'is �,c4'ia, I ;i Warranty': 4 to 5 year 4 to 5 year 4 to 5 year rfacne11t full replacement full replacement Service Life: Extended Extended Extet d"ed°I Runtime(minutes)2: 221 196 165 Sealed VRLA: Valve regulated lead acid Valve regulated lead acid Valve regulated lead acid Heat Resistant: Extreme Extreme Extreme Hydrogen Emission: Low Low Low Terminals: Threaded insert Threaded insert Threaded insert 1/4"-20UNC 1/4"-20 UNC 1/4'-20UNC Specifications4 Typical Runtime(minutes)2: 221 196 165 Cells Per Unit: 6 6 6 Voltage Per Unit: ! 12.8 12.8 12.8 Conductance Value: i 1175 1100 1000 Max.Discharge Current(A): 900 900 800 Short Circuit Current(A): 2800 2600 2500 10 Second Volts @ 100A: 11.4 11.3 11.2 Ohms Impedance 60Hz: 0.0050 0.0050 0.0055 Nominal Capacity at 20hrs:(to 1.75VPC) 109Ah 100Ah 86 Nominal Capacity at 20hrs:(to 1.70VPC) 110Ah 102Ah 87 BCI Group Size: 31 31 27 Weight(lb/kg): 73/33,2 67/30.5 63/28.6 Height w/Terminals(in/mm): 8.48/215,4 8.48/215.4 8.05/204.5 Width(in/mm)3: 13.42/340.9 i 13.42/340.9 12.5/317.8 Depth(in/mm)3: 6.80/172,7 6.80/172.7 6.83/173.4 Operating Temperature Range Discharge: -40 to 71°C -40 to 71°C 40 to 71°C (-4010160°F) (-40 to 160°F) (-40 to 160°F) Charge(with temp compensation): -23 to 60°C -23 to 60°C .23 to 60°C (-9.4 to 140`F) (-9.4 to 140°F) (-9.4 to 140°F) Float Charging Voltage(Vdc): 13.5 to 13.8 13.5 to 13.8 13.5 to 13.8 AC Ripple Charger: 0.5%HMS or 1.5%of fldat-charge voltage recommended for best results.Max.allowed=4%P-P Notes 1 Warranty varies by country and region.Warranty valid only when used with Alpha approved Power Supplies,Chargers and Enclosures.Consult your sales person for details. 2 Runtimes calculated using a 25A DC constant current load. 3 Dimensions at top of battery. 4 See AlphaCell Users Guide for Additional Details. Typical Standby Time in Minutes @ 25 C/77°F .. � '1 °e .� ,4 z. W. y„ � 4��. , ,ee 0*'f', 3batteries: 453.: 396 320 285 249 236 209 195 : 186 165 144 4babsries: 701 625 548 444 396 346 329 293 256 261 232 203 6b45aiies 1091 98 853 701 625 546 523 465 407 418 372 325 8batteries: 148' 1338:: 1166 960 859 750 720 643 5E2 577 515 450 9battaies: 16 1519 S 1,377 1131 976 853 620 733 640 659 587 514 ,�. �ff Vii. 3batedes 149 132 115 119 106 92 „< °101 hoe: 89 77 87 78 .,.°, 66 4batt ies. 210 187 163': 169 151 132 144 126 112 124 111 96 6batbaies: 339 : 301 264': 275 245 214 236 209 183 204 182 159 8b16taies: 476. 419 367: 385 341 299 329 293 255 288 255 223 9battene4. 538 479 419 440 391 342 377 335 294 329 293 256 om.. °A8 ti*'" '%� N. 3b1620e6 796 '712 622 508 453 396 377 335 294 300 267 233 4batteties 1791 978 853'. 701 625 546 525 '.. 465 407 418 372 325 6baltenes: tee 1519 '.. 1,327 1091 978 853 820 733 640 659 587 514 8balOies: 2933 2 1786: I.. 1417 133 1165 : 1122 1006 877 904 809 706 9balBaies. 2330 245 2767', 1626 1519 1322 : 1273 1143 997 1027 921 833 3battaies 242 215 188'. '.. 196 174 151 166 148 125 :. 144 128 107 4batte1es: 336 301 264 275 245 214 236 209 182 ' ! 204 182 155 6batteies 536 479 419'.. '- 440 391 340 377 335 290 329 293 252 8bat0sies: 741 660 577'.. 607 541 470 523 465 402 458 407 351 9b18eries: 643 753 658 692 617 538 597 - 531 462 523 465 402 "Above calculations based on an AC load with a.90 cable plant powerfactor For contact information visit www.alpha.com The Alpha Group> North America Europe,Middle East&Africa Asia Pacific Latin&South America Canada Cyprus Germany Lithuania P.R.China Contact USA office Tel.+1 604 430 1476 Tel:+357 25 375 675 Tel+49 9122 79889 0 Tel:+370 5 210 5291 TeL+852 2736 8663 Fax+1 604 430 8908 Fax:+357 52 359 595 Fax:+49 9122 79889 21 Fax.+370 5 210 5292 Fax+852 2199 7988 Toll Free+1 800 667 8743 USA Russia United Kingdom Tet+1 360 647 2360 Tel+7 495 925 9844 Tel.+44 1279 501110 Fax+1 360 671 4936 Fax:+7 495 916 1349 Fax:+44 1279 659870 Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice. 049-297-10-0003(10/09) Copynght 0 2009 Alpha Technologies.All Rights Reserved.Alpha®is a registered trademark of Alpha Technologies. Alpha Outdoor Enclosure Side Mount 6 'x Traffic grade aluminum enclosure protects battery e, backup power systems from outdoor elements Pp Y Ex' r Large sun shield, thermostatically controlled fan, e and louvered vents ensure reliable operation in , high temperatures 180° stainless steel piano hinged door with two locking open positions making installation and maintenance easy and convenient . Three-point latching mechanism with Corbin Type 2 lock or optional Best lock for maximum security *Shown with Alpha UPS module, transfer switches, and AiphaCell batteries. The Alpha Outdoor Enclosure Side Mount 6 is designed to protect traffic industry battery backup power system components from harsh outdoor elements.The ruggedized enclosure is made of 0.125" aluminum and designed to easily accommodate an Alpha uninterruptible power supply(UPS) module, Alpha transfer switches, and four AlphaCellTM 210 GXL or 215GHP batteries with room for additional components that may be required for your application.The Side Mount 6 is an outdoor rated (NEMA 3R)enclosure. This new and improved Alpha enclosure replaces the Alpha S4 and features a number of improvements over the S4 including: stainless steel door handle, integrated lock and latch, an integrated document holder, and angled generator plug with water tight generator door (generator plug option). Additional options and accessories are available (see listing on next page). Alpha Technologies member of The cULOJ Group' Ism Alpha Outdoor Enclosure Side Mount 6 I .I$hang i pecn cation •Dimensions(cm): 122H x 42W x 42D y (in): 48.1H x 16.5W x 16.5D 1u c •Weight(enclosure only) € no options(kg/lb) 75/34 •Mounting: Side mount(standard) °� P Stand alone �q ) (optional ground mount pedestal) •Construction NEMA 3R Rated,0.125"aluminum (5052-H32)enclosure-meets the harsh ` 1g outdoor demands of the traffic industry. � ,_; Jai pecffic tiont'. •Cooling. Field replaceable themostatically controlled fan,louvered vents.washable filters + ) to keep dust and other particles out a f anc •Agency Certification: UL50/CSA s 414 ' r e • �� ..,;fin'j4; :� 3 ° e��u ,•I •Designed to mount to the side of most traffic enclosure cabinets • • Stainless Steel handle for extended life and improved look •Three point latching mechanism with Corbin Type 2 lock or optional Best lock for maximum security •180°stainless steel piano hinged door with 2 position prop makes maintenance access easy *Shown with optional locking generator access door •Removable bottom shelf for easy wiring access •Bug screen protected top vent •10 year warranty(subject to terms and conditions) •Two extra large shelves each capable of holding two Alpha 210 GXL or 215 GHP batteries •Generator support:locking generator access door and L5-30 Fl plug •Universal Generator Transfer switch •Universal Automatic Transfer switch •AlphaGuard battery balancer •Battery heater mats •Surge suppression device • On Battery"indicator light •Door activated interior light •Tilt switch •Tamper switch •Ground mount kit For more information visit:www.alpha.com/traffic Alpha Technologies Toll free:1 800 667 8743 Direct:604 430 1476 #046-003-00(05/091 Due to continuous product improvement and modifications,Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice. Copyright©2009 Alpha Technologies. All Rights Reserved. Alpha°is a registered trademark of Alpha Technologies. Member of The Alpha GroupTM is a trademark of Alpha Technologies. Alpha Transfer Switches Outdoor Solutions gym 3psf r" ATasY A. <, 2 > Alpha Universal Automatic Transfer Switch (UATS) .............._._.___........._.___. . . ...... ............... ..........__._...... > Fail safe and manual operation ensures critical load is protected > Optional dry contact for monitoring transfer switch status: know exactly what your transfer switch is doing > Auxiliary output can be used to power items such as battery heater mats eliminating the need for additional complex wiring The UATS ensures continuous operation of your systems either with conditioned line power,battery backup power or power direct from the line should the UPS require maintenance. al gi, ;::' 4 6.'t' > Alpha Universal Generator Transfer Switch (UGTS) > Automatic and manual operation for complete control over generator transfers .> Optional dry contact for generator transfer switch monitoring The UGTS automatically transfers the input to the UPS from the utility line to a portable AC generator,The UGTS allows the generator to recharge the batteries and power your systems during extended power outages. For a full set of configurations,see the UATS and UGTS manual(Document#020-165-80) h? TECHNOLOGIES" Your Power Solutions Partner TECHNOLOGIES' Alpha Transfer Switches yq .y a.« ssf:�.,..Te� r '�, .. i' \2 6,".... s Z L �,..r_..„x a • :,!• § Vin. 9 ,- >North America Generator/line manual selector Input voltage: 120V nominal,102V minimum for auto transfer Easy installation convenience outlet(UATS only) Output voltage: Matches Input Spare fuse and mount >International Input voltage range: 230V nominal,196V minimum for auto transfer Output voltage range: Matches Input Operating temperature:....-40 to 74°C(-40 to 165°C) >Power Module ,r4, Mi . North America: Part Number. 020-165-21 •Dry contact indication status mode Nominal voltage: 120V •Wall/Shelf mounting bracket Nominal frequency 60Hz •Single side mounting bracket Input current: 30A Output current: 30A to Output power at 40°C: 3600W/VA CE International: cus ” Nominal voltage: 230V CAN/CSA C22.2 No.107.3-05 Nominal frequency: 50Hz UL1778 4th Edition Uninterruptible power systems Input current 16A CE:As component type for FXM UPS family and Micro UPS family Output current: 16A (when enclosed in a box) Output power at 40°C: 3600W/VA EMC:Not applicable " w , , ., Dimensions: mm: 81H x 135W x 152D in• 3.25H x 5.3W x 6.0D Weight: 1.6kg(3.51bs) Unit weight: 11kg(251bs) • • Universal Automatic Transfer Switch(UATS-far right)and Universal Generator Transfer Switch(UGTS-center)shown with surge protection(TVSS-left)in a 19'rack mount bracket(23'rack mount bracket also available). Alpha Technologies Ltd. For more information visit www.alpha.ca Canada:Burnaby,British Columbia Tel:604 436 5900 Fax:604 436 1233 #0480029-00 Rev A (12/2010) United States:Bellingham,Washington Tel:360 647 2360 Fax:360 671 4936 �}-� -, Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice. member of The`''9i""'Group' Copyright©2010 Alpha Technologies.At Rights Reserved.Alpha®is a registered trademark of Alpha Technologies. member of The Alpha Group°.is a trademark of Alpha Technologies. AlphaGuardTM Battery Charge Management System _ n con' 1•• > Extends battery life > Replace only single batteries, not the entire string > Spreads charge voltage equally across batteries > Compensates for battery differences as they age > Optional communications interface module tracks battery voltage and prevents discharge damage > Safe unattended operation designed to CSA C22.2 No. 107.1 and UL 1778 Standards AlphaGuard monitors and protects your batteries by spreading the charge voltage equally across all the batteries in a string, ensuring that every battery in the string, whether old or new, is properly charged.With an ideal voltage always across each battery, life and runtime are optimized. Individual batteries in a string can be replaced as they fail, allowing batteries to be left in service longer. This stops the wasteful and costly practice of disposing of batteries that may have years of useful life left because one battery in a string fails or replacing batteries based on a scheduled maintenance program.With the optional communications cabling and interface module individual battery measurements are made at the batteries and reported, improving accuracy and allowing the supply to determine End-of-Discharge by individual batteries instead of the string voltage and reporting to status monitoring systems. Alpha Technologies member of The Group"' 'Phu' u rilirir AlphaGuard The AlphaGuard employs a patented Charge Management Technology(CMT)to shuttle excess charge current from one battery to a battery requiring a greater charge and is contained in a small plastic enclosure that installs directly on top of one the batteries in the string.A short service cable connects the AlphaGuard to each of the batteries in the string.Both 36VDC(3 battery)and 48VDC(4 battery)versions are available.One AlphaGuard is required per string. An AlphaGuard configured with an optional communication interface module allows the AlphaGuard to interface with a status-monitoring module. Two AlphaGuard modules can be connected to an interface module.Optional interface modules include EDSM,ESM and DSM. Models AG-CMT-3: AlphaGuard Charge Management SC,36V String—including 36VDC battery interface cable AG-CMT-4: AlphaGuard Charge Management SC,48V String—including 48VDC battery interface cable Configuration Quantity: One(1)AlphaGuard is required per battery string Service Location: With the battery string Cabling AG-EDSM-S9-Cable: AG-CMT-36/48SC to EDSM Voltage Sense Cable,Single String,9' AG-EDSM-D9-Cable: AG-CMT-36/48SC to EDSM Voltage Sense Cable,Two String,9' AG-EDSM-S35-Cable: AG-CMT-36/48SC to EDSM Voltage Sense Cable,Single String,35' AG-EDSM-D35-Cable: AG-CMT-36/48SC to EDSM Voltage Sense Cable,Two String,35' Mechanical Housing Material: High impact plastic Dimensions(in): 1.44H x 4.82W x 4.25D (mm): 36H x 122W x 108D Weight(lb/kg): 0.8/.36 Electrical Batteries: Individual 12VDC nominal batteries configured into 36 or 48VDC strings Circuit Protection: Single blow fuse,reverse polarity protected Environmental: -40 to 55°C(-40 to 131°F),5 to 95%humidity Quiescent Current Draw: 1mA max.(Current consumed by AlphaGuard after low voltage total shutdown) Charge Management: Most effective during float period of charge Max.Current: 2A @ 25°C Quality of Final Balance: ±100mV max.between any two(2)batteries Charging Efficiency: 80 to 90% Charge Balance: ±100mV typical Low Voltage Cutoff/End of Discharge: Determined by the lowest per cell voltage any battery in the string Programmable 1.80 to 1.65V per cell Communication to XM2: AlphaGuard configured EDSM communications card Voltage Sense Regulation: ±100mV Warranty 5 years • , u AG-EDSM-S9-Cable AG-EDSM-D9-Cable AG-EDSM-D35-Cable AG-EDSM-S35-Cable For more information visit www.alpha.com Alpha Technologies United States Bellingham,Washington Tel:360 647 2360 Fax:360 671 4936 049-225-t0-004(1/06) Canada Burnaby,British Columbia Tel:604 430 1476 Fax:604 430 8908 Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice. Copyright©2006 Alpha Technologies.All Rights Reserved.Alpha"is a registered trademark of Alpha Technologies.The Alpha Group°°is a trademark of Alpha Technologies. J•JY • 4$ :. • .1- (y • •f z • z6c. • • . :s Local Remote Indicator Assembly, LED, Red, 48-60V, Enclosure, Novus Series Fiber OptiTip® Interconnect Harness Assemblies CORNING Features and Benefits OptiTip"'Interconnect Harness Assembly is designed for use in outside plant fiber access networks with OptiTipe'MT preterminated cabling solution FIexNAPTM and OptiSheathe MDU and Fiber Distribution Up to 50 percent faster per system deployment terminals.This innovative cable assembly solution pro- Factory-tested vides enhanced design flexibility,increased deployment Quick,reliable installation speed and reduced installation cost.The OptiTip MT Connector design provides superior durability and reliabi- Flexibility for various network designs lity for network point connections up to 12 fibers. Indoor and outdoor application The OptiTip Interconnect Harness Assembly is available OptiTip MT Connector with SST-DropTM Outdoor Cables or FREEDMC Flat-Drop Compatible with FIexNAPTM System, MDU terminals, indoor/outdoor LSZHTM Cable,which allows for easy FDT stubbed terminals migration of indoor and outdoor applications.The OptiTip Robust design keeps connector intact during instal- Interconnect Harness Assembly is available with either lation pinned or non-pinned OptiTip MT Connectors to match Integral pulling eye/connector cap designed for 100 lb your network needs. maximum pulling tension Standards Design and Test Criteria Telcordia GR-3152 RUS, GR-3120 OptiTip Interconnect Harness Assembly OptiTip MT Connector Photo CCA225 I Photo LAN1000 Family Spec Sheet 0271 NAFTA AEN CORNING Page 1 I Revision date 2013-09-19 OptiTip® Interconnect Harness Assemblies CORNING Specifications Connector °` � ��� �� .��� � `.,�b insertion Loss,Typical 0.35 dB Reflectance$:Typical -65 dB Axial Pull, Plug to Adapter 50 lb Coupling trength" 4161 Ptilt;Plitg to Cable, 100 lb 7(tirfeugOffiatluSt' p cold Mate{ emate -40°C mechanical testing Cable span distances are subject to customer environmental loading and sag specifications. Family Spec Sheet NAFTA AEN C ORl\TING Page 2 I Revision date ate 2013-09-19 OptiTip® Interconnect Harness Assemblies CORNING Ordering Information E - P Select connector type 1. Defines fiber type. Select cable assembly unit 00 = No connector(pigtail) E=Single-mode of length. M1 = OptiTip5 MT Connector F = Feet (non-pinned), M= Meters single-mode Select cable type. B4D1E = SST-Drop Outdoor Cable Defines packaging. Select connector type 2. BZD1X= FREEDM Flat Drop P = Individual packaging for all M1 = OptiTip MT Connector Indoor/Outdoor lengths. Shipping reel (non-pinned), LSZH Cable ' supplied with lengths single-mode i >350 ft. M2= OptiTip MT Connector (pinned), single-mode 6 Select length. Use all spaces Example: 50 feet=050 El Select fiber count. Length increments of 10 ft or 06 = 6fibers 25 ft; 5m 12 = 12 fibers See Notes 1 and 2. 1)10 ft increments only 2)For lengths greater than 1000 ft/m,contact Customer Care. Corning Cable Systems LLC•PO Box 489•Hickory, NC 28603-0489 USA 800-743-2675•FAX:828-325-5060•International:+1-828-901-5000•www.corning.com/cablesystems A complete listing of the trademarks of Corning Cable Systems is available at www.corning.com/cablesystems/trademarks. Corning Cable Systems is ISO 9001 certified.©2013 Corning Cable Systems.All rights reserved. Page Spec Sheet date 2 NA09-19 CORNING Page 3 I Revision date 2013-09-19 AnyLANTM Integrated Single-Panel Housing CORNING Features and Benefits Corning Cable Systems AnyLANTM Integrated Single- Panel Housing utilizes the AnyLAN OptiTip®Adapter Compatible with Plug&PlayTM AnyLAN TM Solutions with the small-profile single-panel housing for quick and Ease of installation and moves,adds and changes easy deployment eliminating the need for field-termi- Factory-terminated nated and strain-relieved fiber optic cables.The housing Eliminates need for field termination, improving reliability is fully compatible with existing Plug &Play TM AnyLAN and speed of deployment Solutions and is ideal for star,ring, point-to-point or zone architectures. Factory-terminated panels provide indus- Configurable in 12 and 24 fibers,single-mode and try-leading quality and reliability while eliminating the time multimode,supporting SC, LC and Sr'Compatible required for field-termination methods and the need for Connectors specialized field-termination tools,training and specially Network flexibility prepared locations.The compact unit is ideal for use inside NEMA-rated and IP-rated enclosures and other environments where space is a premium. 4110 - AnyLAN Integrated Single-Panel Housing(closed) AnyLAN Integrated Single-Panel Housing(open) I Photo LAN1643 I Photo LAN1642 Family Spec Sheet 0160 NAFTA AEN CORNING Page 1 I Revision date 2013-08-29 AnyLANTM Integrated Single-Panel Housing CORNING Specifications Dimensions(HxWxD) Shipping iftteight AnyLANTM Integrated 16.5 cm x 15.2'cm x 3.8 cm 0.7 kg Single-Panel Housing (6.5 in x 6.0 in x 1.5 in) Ordering Information Part Number Description Units per Delivery SPH-120TS-12H3H AnyLANT"' Integrated Single-Panel Housing, 12 F, 1(1 bottom-mounted OptiTip®Adapters,front-mounted ST®Compatible Adapters,50 pm Multimode(0M3) SPH-120TC-12D3H AnyLANT"" Integrated Single-Panel Housing, 12 F, 1/1 bottom-mounted OptiTip'Adapters,front-mounted LC duplex Adapters,50 pm Multimode(0M2) SPH-120TC-12G5H AnyLANTA° Integrated Single-Panel Housing, 12 F, 1/1 bottom-mounted OptiTip®Adapters,front-mounted ST®Compatible Adapters,50 pm Multimode(0M2) SPH-120TC-12G7H 12 F, bottom-mounted OptiTip''Adapters,front-moun- 1/1 ted SC duplex Adapters,50 pm Multimode(0M2) SPH-120TR-1259H AnyLANTM Integrated Single-Panel Housing, 12 F, 1/1 bottom-mounted OptiTip®Adapter,front-mounted SC duplex Adapters, Single-mode(0S2) SPH-120TR-126TH AnyLANT"" Integrated Single-Panel Housing, 12 F, 1/1 bottom-mounted OptiTip®Adapter,front-mounted ST® Compatible Adapters, Single-mode(052) SPH-120TR-12A9H AnyLANTM Integrated Single-Panel Housing, 12 F, 1/1 bottom-mounted OptiTip®Adapters,front-mounted LC duplex Adapters, UPC,Single-mode(0S2) SPH-12OTS-12E4H AnyLANT"" Integrated Single-Panel Housing, 12 F, 1/1 bottom-mounted OptiTip®Adapters,front-mounted LC duplex Adapters,50 pm Multimode(0M3) SPH-120TS-12E7H AnyLANTM',Integrated Single-Panel Housing, 12 F, 1/1 bottom-mounted OptiTip®Adapters,front-mounted SC duplex Adapters, 50 pm Multimode(0M3) SPH-240TC-24D3H AnyLANT"" Integrated Single-Panel Housing,24 F, 1/1 bottom-mounted OptiTip®Adapters,front-mounted LC duplex Adapters,50 pm Multimode(0M2) SPH-240TR-24A9H AnyLANT^' Integrated Single-Panel Housing,24 F, 1/1 bottom-mounted OptiTip®Adapters,front-mounted LC duplex Adapters, Single-mode(0S2) SPH-240TS-24E4H AnyLANTM Integrated Single-Panel Housing,24 F, 1/1 bottom-mounted OptiTip®Adapters,front-mounted LC duplex Adapters,50 pm Multimode(0M3) Page Spec Sheet date 2 NA08- AEN CORNING Page 2!Revision date 2013-08-29 AnyLANTM Integrated Single-Panel Housing CORNING Notes RoHS C O MAN T Corning Cable Systems LLC•PO Box 489•Hickory,NC 28603-0489 USA 800-743-2675•FAX: 828-325-5060•International:+1-828-901-5000•www.corning.com/cablesystems A complete listing of the trademarks of Corning Cable Systems is available at www.corning.com/cablesystems/trademarks. Corning Cable Systems is ISO 9001 certified.©2013 Corning Cable Systems.All rights reserved. Family Spec Sheet date 2 NA08- AEN CORNING Page 3 I Revision date 2013-08-29