CF-Cozby Library-LR 940324 (3) MOISTURE DENSITY RELATIONSHIP REPORT
Test Report Date:March 24, 1994
Client: City of Coppell
Sample Date: March 18, 1994
project: W.T. Cozby Library
Identification: Moisture Density Relationship
Test Procedure: ASTM D698
Test Results:
Method ......................................... A
Optimum Moisture Content ............................. 12.0 percent
Maximum Density .................................. 113.9 pounds per cubic foot
Rammer Type ..................................... Manual
Material Description ................................. Dark Gray Silty Sandy Clay
Material Origin .................................... S ubgrade at S.E. Comer of
Building Pad
Moisture Preparation Procedure .......................... Air Dry
Liquid Limit ...................................... 27
Plastic Limit ...................................... 10
Plasticity Index .................................... 17
Percent Passing a No. 200 U.S. Sieve ...................... 57
Technician: Richard W. Gee/Gary G. Huang
cc: Mr. Gary Sieb - City of Coppell
Mr. Jim Bullock - F & S Panners
Mr. Mike Sherpinskas - Diversified Construction Services
Mr. Russell Williams - Brockett, Davis & Drake
Our letters and repots arc for thc exclusive usc of thc client to whom they arc addressed. The u~ of our name must receive our prior wriO. cn approval. Our letters and reporla
apply only to thc sample lestcd and/or inspected, and arc not necessarily indicative of the quantities of apparcntly identical or similar products.