Acct ID: 1770 File No: C13 -0634 Date Sampled: 11/26/2013
Report Date: 11/27/2013 Sampled By: Caleb Hernandez
Project: West Sandy Lake Road By Order Of:
Location: Concrete on bridge deck and approach Order Number: 1770
Client: City of Coppell
REPORT: Reinforcing Steel Inspection LAB NO: 155102 -1
TEST RESULTS Report No: 155102 -1
Page 1 of 1
On the basis of our visual inspection, the reinforcing steel placement meets the requirements of the project plans and
specifications.
Other: Bridge deck approach slab on east side
DRAWING DATE: 3 -28 -13 ADDENDUM NO: Sheet 125 DATE: 11 -26 -13
DETAILS REFERENCED: [Double Mat] (Bottom Matt) had A's ( #8) at 6" O.C. on bottom with D's ( #5) at 12"
O.C. on top. Chairs were placed between mats.
(Top Matt) had T's ( #5) at 12" O.C. on bottom w /B's ( #5) at 12" O.C. on top.
E and F Bars ( #5) were already on place in support slab @ 12" O.C.
Area was free of trash and debris. There was 2" coverage on top and bottom as well as on the sides.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kak a, CME Department Manager