Loading...
CF-Cozby Library-LR 940520 (09) REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOHJ Method: ASTM D2922 D3017 D698 Page 1 of 2 Client: City of Coppell Material Dcscriptio~ Maximum Optimum Dr)' Moisture Density Content Project: W.T. Cozby Library (Lbs/CuF0 Percent Test Date: April 7, 1994 1. Select Fill: Reddish Brown Clayey Sand 112.5 13.2 Report Date: May 20, 1994 2. Required Density (%): 95% to 105% 3. Required Moisture (%): +3% Optimum 4. Mat Location/Elevation (and/or) LiR In-Place In-Place Percent No. Dry Density Moisture Compaction Test (Lbs/Cult) Content (~) No. Probe Deplh 1 Building Pad Select Fill - 2"o Lift 36 109.6 12.1 97.4 6" 42' east and 51' north of southwest corner 1 Building Pad Select Fill - 2"d Lift 37 112.5 13.9 100.0 BS 30' east and 12' south of northwest corner 1 Building Pad Select Fill - 3rd Lift 38 109.9 16.1 97.7 BS 30' south and 18' west of northeast corner 1 Building Pad Select Fill -3rd Lift 39 116.7 13.2 103.7 BS 45' south and 39' west of northeast corner 1 Building Pad Select Fill - 3~ Lift 40 108.4 16.2 96.4 6" 24' west and 30' north of southeast corner Above Test Results Meet Specification Requirements GEE Consultants, Inc. (214) 620-9791 REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOIl, Method: ASTM D2922 D3017 D698 Page 2 of 2 Client: City of Coppell Malerial Dcscriptioa Muximum Optimum Dry Moismre Density Content Project: W.T. Cozby Library (Lbs/CuFt) Percent Test Date: April 7, 1994 1. Select Fill: Reddish Brown Clayey Sand 112.5 13.2 Report Date: May 20, 1994 2. Required Density (%): 95% to 105% 3. Required Moisture (%): +3% Optimum 4. Mat Location/Elevalio~ (and/or) Lift In-Price In-Place Percenl No. Dry Density Moisture Compaction Test No. (Lbs/CuFt) Content (5{) Probe D~pth 1 Building Pad Select Fill - 3'd Lift 41 109.8 1:5.9 97.6 BS 12' south and 100' west of northeast comer 1 Building Pad Select Fill - 3rd Lift 42 108.2 12.5 96.2 4" 60' south and 75' west of northeast corner 1 Building Pad Select Fill - 3~d Lift 43 113.1 15.7 100.5 6" 24' north and 90' west of southeast corner 1 Building Pad Select Fill - 3ra Lift 44 108.1 12.8 96.1 BS 45' north and 90' east of southwest corner 1 Building Pad Select Fill - 3ra Lift 45 108.6 15.1 96.5 6" 120' east and 45' south of northwest comer Above Test Results Meet Specification Requirements cc: Gary Sieb - City of Coppell Mike Sherpinskas - Diversified Construction Services, Inc. Jim Bullock - F & S Partners Robert Williams - Brockette Davis Drake, Inc. Our letters and ~po~ are for th~ exclusi;e ~se of th~ client to whom they are addressed. Th~ uc, e of our name must receive our prior ~,-ritten approval. Our letters and reports apply only to the sampk: tes,.ed sM'or inspe, cted, and are nol m~e~sarily indicative of th~ q',.mntitiea of appamntl:, identical or similar produc~.