CF-Cozby Library-LR 940520 (10) REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOIL
Method: ASTM D2922 D3017 D698 Page 1 of 2
Client: City of Coppell M~terial Description Maximum Optimum
Dry Moisture
Densi~' Content
Project: W.T. Cozby Library (Lbs/CuFf) Percent
Test Date: April 8, 1994 1. Select Fill: Reddish Bro~ Clayey Sand 112.5 13.2
Report Date: May 20, 1994 2.
Required Density (%): 95% to 105% 3.
Required Moisture (%): _+3% Optimum 4.
Mat Location/Elevation (and/or) Lift In-Place In-Place Percent
No. Dr)' Density Moisture Compaction
Test
No. (Lbs/CuF0 Content (~)
Probe.
Depth
1 Building Pad Select Fill - 3rd Lift
46 116.8 12.8 103.8
BS 15' east and 27' north of southwest corner
1 Building Pad Select Fill - 3rd Lift
47 112.7 14.1 100.2
6" 60' north and 51' east of southwest comer
1 Building Pad Select Fill - 3~ Lift
48 112.6 12.4 100.1
BS 24' south and 12' east of northwest corner
Above Test Results Meet Specification Requirements
cc: Gary Sieb - City of Coppell
Mike Sherpinskas - Diversified Construction Services, Inc.
Jim Bullock - F & S Partners
Robert Williams - Brockette Davis Drake, Inc.