Loading...
CF-Andrew Park 2-LR 940110 (2)Gifford-Hill & Company 240 SINGLETON BLVD. · DALLAS, TEXAS 75212 RO. BOX 655688 * DALLAS, TEXAS 75265-5688 DALLAS CONCRETE PHONE 2141748-8061 FAX 214/748-5004 ~Ii~IIB.IIILL _ January 10, 1994 TO: Rodman Excavation PROJECT: Andre Brown Jr. Comm. Park SUBJECT: Proposed Mix Design SALESPERSON - Mike McAdams Gentlemen: We are pleased to submit the following mix designs for your approval on the above referenced project. Please use our GHS# when ordering concrete. MIX DESIGN PROPORTIONS - ONE CUBIC YARD (SSD) Specified 28 day Strength(f'c) Mix Number Cement Type I Flyash - Class C ASTM #57 Aggregate Sand Water Water Reducing Admix Air Entraining Agent Superplasticizing Admix DESIGN MIX CHARACTERISTICS. Slump - Inches Unit Wt. - lb/CF (plastic) W/C Ratio - lb/lb Air Content - % Flyash - %/WT 3000 PSI GMS# 18 470 lbs. lbs. 1900 lbs. lbs. 1376 lbs. 240 lbs. 14.1 ozs, 2.8 ozs. OZS. COMPRESSIVE STRENGTH,'PS! - From Attached Curves - 3 - 5 147.6 Test Age .50 3 - Day 3.5 - 6.5 7 - Day 28 - Day 4900 The above mix design is guaranteed to achieve specified compressive strength when tested and evaluated in accordance with applicable ASTM and ACI test methods and specification. We would appreciate notification of mix design approval before commencement of concrete placement. Please do not hesitate to call if You have any question concerning the mix design data. Resp~d, ~Niciola~s ~ Quality Control Manager Gifford-Hill & COmpany 240 SINGLETON 8LVO · DALLAS. +EXAS 75212 PO. BOX 655688 * DALLAS. TEXAS 75265-5688 DALLAS CONCRETE PHONE 2141748.80~1 FAX 214/748-5004 To: Ail Customers Re: Concrete Test Reports Dear Customer, The Standard Specification for Ready-Mixed Concrete, ASTM designation C 94, includes the following stipulation. ,,When the strength of concrete is used as a basis for acceptance, the manufacturer shall be entitled to copies of all test reports." Please be sure we are added to the mailing list for copies of concrete test reports. The reports should be sent to my attention. Thank You, Frank Nickolaus Quality Control Manager Technical $~rvices Division cea, n! fl _GH Eidlothfan Ty~e ! T$-72i5-89 $ I FFORD-H / L L & COKPAI(V, INC. CONCR[T[ TEST SUH~ARY PROJECT 90174 Gilford-Hill Dallas Concrete Sion, ~! _OH Brldaeoort 157 (1'-~_4) TS-7567:90 Sandfl GH Ferrfs Natural River TS-7246-B) NIsc. KISC. Dallas Concrete(Ps#90 7) Lab Trial Mixtures - 1 ~ T~:h 5e~ L~b (~i~ Nos. 14,,~)C-47DC) 9.0 ~- 8.0- 4.0 - 1 I I Lab Trial Mixtures - Dallas Concrete(Ps#9017z+) ~-I Teen Sen Lob (~[x N~ 1430C-4.70C) 10.0 ~ 9.0- 8.0- - 7'.0- ~.o- m ~o 5.0 - 1:3 2o i£ e"' 4.0 - 1.0- o 1-0 + ~-D ~ 7-D 628-1)