ST9902-LR140115Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Date Sampled: 12/18/2013 Report Date: 01/16/2014 Previously Reported: 12/26/2013 Sampled By: Hernandez, Caleb Project: West Sandy Lake Road By Order Of: Location: Various Locations Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 155594 Test Method: See Below TEST RESULTS Report No: 155594 Page 1 of 2 Set: 1 of 2 Material: Concrete Location: Manhole Top on West Sandy Lake at Station 6 +52 Number of Specimens: 4 EXE RM M FIKE 1� Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,000 psi @ 28 days Slump: 3 -5 Air Content: 3 -6 Date Received: 12/19/2013 Curing Method: Standard Maximum 1:30 pm Time Batched: Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 12/25/13: 7 6.00 28.27 100,370 Type 3 Lab 3,550 B 12/25/13: 7 6.00 28.27 113,650 Type 5 Lab 4,020 3,780 C 01/15/14: 28 6.00 28.27 129,255 Type 3 Lab 4,570 D 01/15/14: 28 6.00 28.27 133,620 Type 3 Lab 4,730 4,650 EXE RM M FIKE 1� Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,000 psi @ 28 days Slump: 3 -5 Air Content: 3 -6 Date Received: 12/19/2013 Curing Method: Standard Time Sampled: 1:30 pm Time Batched: 12:34 pm Temp.: Ambient: 70 °F Mix: 63 °F CONFORMS Slump: 4.0 Inches Transported By: LMC Air Content: 7.5% Source /Sampled At: Truck / Center Mix Code: 1261 Plant: 95 Truck /Ticket No: 5007 / 96077086 Quantity Represented: 7.5 cu. yds. at 7.5 cu. yds. placed of a 7.5 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. 7q ii i pA Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Date Sampled: 12/18/2013 Report Date: 01/16/2014 Previously Reported: 12/26/2013 Sampled By: Hernandez, Caleb Project: West Sandy Lake Road By Order Of: Location: Various Locations Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 155594 Test Method: See Below TEST RESULTS Report No: 155594 Page 2 of 2 Set: 2 of 2 Material: Concrete Number of Specimens: 4 Location: Railing on South Side of Bridge, 20ft West of Station 65 +60 and 20ft East of Station 67 +60; Sampled Railing at 1 Oft West of S Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments A 12/25/13: 7 6.00 28.27 99,300 Type 3 Lab 3,510 B 12/25/13: 7 6.00 28.27 92,850 Type 5 Lab 3,280 3,400 C 01/15/14: 28 6.00 28.27 135,800 Type 3 Lab 4,800 D 01/15/14: 28 6.00 28.27 140,205 Type 3 Lab 4,960 4,880 HE Erg M F1_ 111111 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification CONFORMS Strength: 4,000 psi @ 28 days Slump: 3 -5 Slump: 5.0 Inches Transported By: LMC Air Content: 3 -6 Air Content: 5.9% Source /Sampled At: Truck / Center Mix Code: 5507 Plant: 952 Date Received: 12/19/2013 Truck /Ticket No: 7009 / 62957566 Curing Method: Standard Time Sampled: 2:30 pm Time Batched: 1:29 pm Temp.: Ambient: 70 °F Mix: 65 °F Quantity Represented: 8 cu. yds. at 8 cu. yds. placed of a 8 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.