Suppler TXI Spedfied strength @ 7 days: 300-700 psi
Mlx ID: Cement Treated Base Nominal Cylinder Size (in.), 4.00 x 4.58
Mbc Data Sup. Sr. Supplier App8able ASTM Test Standards: DSSB. D 1632
Cylinders Made By: "Associates. Inc.
COMPRESSIVE STRENGTH TEST RESULTS
LOCATION: Sandy Lake Road WB lane, STA 38+00
Results
Set Cyl. Date Age Diameter Helght Area Maximum Compressive Meet
No. No. Tested (Days) n. (in.) In 2 Load (lbs) Strength (psi) Spec.
1 5 1 -11 -14 7 4.00 4.58 12.57 5,430 430 Y
6 1 -11 -14 7 4.00 4.58 1257 6,370 505 Y
AVERAGE COMPRESSIVE STRENGTH: 470
* Test results meet project specifications. except time marked