Loading...
CF-Andrew Park 2-LR 920921ATEC Associates, Inc. 11356 Mathis Avenue Dallas, Texas 75229 (214) 556-2204 METRO 263-1681 FIELD DENSITY TESTS Project Name: ANDRkl/BROWN PARK Client Name: TONY CRAWFORD CONSTRUCTION General Contractor: TONY CILAWFORD CONSTRUCTION Test No. Moisture Dry Density {PCF) Proctor No. 1 22.0 105.0 1677 2 18.3 107.3 1677 3 19.7 98.8 1677 4 16.4 107,4 1677 % of Proctor Spec Actual 9O.O 97.5 90.O 99.7 90.0 91.8 90.0 99.8 (1) Test Location Established by: Grid Lines [] (2) Depth or Elev. of Test Established by: Survey [] (3) Test Conducted on: Full Time Basis Fail Moisture ATEC Job No.: Client Job No.: Elevation/ Refer F.G. 25-02-92-06928-06 Date: Septm~aer 21, 1992 Location Grid Coordinates or Roadway Station "4 Lift 80'North & 120'East of N.W. Corner of Parkin9 Lot ~ Lift 88'West & 70'North of S.E. Corner of Parkin] Lot -4' 120'South of Manhole at North End (Retest) -4' 60'South of Manhole at North End (Retest) Control Points ~---)~ Grade StakesL-] Estimation [] Contractor [] Estimation [] Contractor [] Intermittent Basis [] Proctor No. Maximum Density (PCF) Opt. Moisture (%) 1677 107.6 17.6 Stand. Proctor Mod. Proctor Total Time: ATEC REPRESENTATIVE John R. Travis Remarks: Respectful ly Submi tted,