Loading...
Westhaven 1-LR140109 Ellerbee-Walczak, Inc. AgZ27GEOTECHNICAL ENGINEERING& CONSTRUCTION MATERIALS TESTING SERVICES COMPRESSIVE STRENGTH (6x12 inch. Cylinder) Client: Gilco Contracting Report #: C-8196 Project: Westhaven Distribution: Technician: Teddy L Cummings City of Coppell - Larry Davis Supplier: Gilco Contracting - Leia Hubbard Placement: 1/2/2014 Strength*: PSI —..r,...--- _ _... ID # Age Test Load Strength D ID: Date (lbs.) • y icket: 1 7 1/9 68500 ice~ Truck: 2 7 1/9 69170 Batch Time: 3 28 1/30 Sample Time: 4 28 1/30 Ambient Temp: Material Temp: Air 0/0: Unit Weight (pcf): Consolidation: Slump (Inches): Location: Westhaven Rd. South intersection Remarks: Cylinders molded by contractor and picked up by EWI due to late concrete. No other information was made available. * Specified Strength Requirement or as shown on Concrete Delivery Ticket Specifications: Field and laboratory tests by EWI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 J .: Stan Walczak, President Texas Firm No. F-4610 77 1/1/ 31/ Oa i z-/ ,/, i /" i 1---1 I 4501 Broadway Ave. • P.O. Box 14809 • Haltom City,Texas 76117 Office 817-759-9999 • Fax 817-759-1888 Page 1 of 1