Loading...
Tru-Blu concrete mix design submittal Transmittal December 20, 2013 Logan Creek Construction Co. 4209 Corduroy Rd. Logan Oregon, OH 43616 consrsicroiv co (419) 697-0275 To: The City of Coppell Attention: Larry Davisl Engineering Department 255 Parkway Blvd Re: TruBlu Logistics Coppell, TX 75019 Job Number: A13-121 We are sending you 4 Attached ❑ Under Separate Cover via: the following: ❑ Shop Drawings ❑ Prints ❑ Plans ❑ Other: ❑ Copy of Letter ❑ Change Order ❑ Samples ❑ Total Quantity ❑ Reproducible Specification Submittal Quantity i Date DWG # i Description 1 ' 8/7/13 i 1Mix Design - #10K11514 Paving, Curbs &Approach Except;on Taker. - see 4#acAed These are transmitted as checked below ❑ For Approval ❑ Approved as Submitted ❑ Resubmit copies for approval For Your Use ❑ Approved as Noted ❑ Submit [ ] copies for distribution ❑ As Requested ❑ Returned for Corrections ❑ Return [ ] corrected prints ❑ For Review and Comment ❑ Revise and Resubmit/Work May Not Proceed ❑ FOR BIDS DUE: ❑ PRINTS RETURNED AFTER LOAN Comments: --------- ---- Craig G. Smit Project Mangier . ; }k ► r. 1 Date: 8/6/2013 CONCRETE Mix Number: 10 11514 an EF Technology Mix Design Strength: 4000 Redi-Mix Concrete,L.P. psi @ 28 days A US-Concrete Company Description: 5.5 SK 10% ASH NR AIR 331 N.MainSt Technical s al 76039 •,\ ,. ch Plant No.: 136 Technica}Service: l/) Customer: Potter Concrete, Ltd. (817)-83s Dispatch:(817) 835-4020 Project: Tru Blue Logistics Fax:(817)835-4074 \-\.)4 E-mail: Usage: Paving, Curb &Approach redimixgc�nus-canerele.com wW W.us-concrete.corn ® Saturated Surface Dry Weights Per Cubic Yard Material Source Quantity Vol ASTM C150 Type 1/11 Cement Ash Grove, Midlothian 466 lb 2.37 ASTM C618 Class C Fly Ash Lafarge, Welsh 51 lb 0.30 ASTM C33 No. 57 LS Martin Marietta,Troy 1850 lb 10.78 ASTM C33 Concrete Sand Redi-Mix Concrete 1389 lb 8.47 ASTM C494 A&D NRWR BASF BASF 322N/ BASF 300R 2-4 oz/cw ASTM C260 Air Entrainment BASF AE90 1-4 oz/cy 1,08 I ASTM C94 Water 30 gal 4.00 1 ``� Total Volume: 27.00 1\4\11° Specified Slump 4 +/- 1" Specified Air Percent: 4.5 +/- 1.5% Wet Unit Weight: 148.4 lb/ft-A3 Design w/c ratio: 0.48 The use of an EF Technology mix design will reduce the amount of CO2 entering the atmosphere, thereby reducing potential global warming. "Your Project, Our World" Notes: Please make sure that redimixqc @us-concrete.com is on the list to receive break reports. • This mix has been designed to meet the requirements of this project based on the information seal to Redi•nux Concrete.tl is the responsibility of the purchaser to determine whether this Mx design meets project specifications and is appropriate for the anticipated environment conditions.The specified strength guarantee per ASTM C94 will not be effective unless field sampling has been done per ASTM C172 and ASTM C31 and the laboratory fully compiles with ASTM C39 and ASTM C1077.In the event of limited material availability,substitution of a similar perforrnng material may be required.All substituted materials will meet the appropriate ASTM requirements.In order to maintain the required mix volume,weights of individual Materials may be varied to accommodate different material specific gravities.Material certifications for substituted materials are available upon request. Alt Redi-Mix Con ete mix designs are proprietary and confidential_The information contained in this submittal is only intended for parties associated with this project to validate the mix design materials,properties and its performance.Use of this submittal for other purposes without permission or consent from Redl-Mix Concrete is strictly prohibited.