Loading...
ST9902-LR140129ALLIFINCE GCiEtJTECFIh1tCfiL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Date Sampled: 01/22/2014 Report Date: 01/29/2014 Sampled By: Roberts, Duce Project: West Sandy Lake Road By Order Of: Walter Location: Various Locations Order Number: 1770 Client: City of Coppell REPORT: Nuclear Field Density Test LAB NO: 157241 Test Method: See Below TEST RESULTS Report No: 157241 Page 1 of 2 Optimum Maximum Proctor Moisture Dry Density Percent Proctor Density Proctor No Date (%) (pcf) Color/ Description 148639 -1 07/17/2013 16.6 106.2 Dark Brown Sandy Clay 148639 -2 07/17/2013 12.0 115.9 Medium Brown Sandy Clay Specification 17.6 103.9 19.8 101.1 20.1 102.5 17.9 104.4 16.9 105.7 17.3 104.1 Proctor Number Spec. No. Moisture Band Percent Proctor Density Specification No. Compaction, % Minimum Maximum 122.2 1 95 0.0 4 +50 5.0 6 -5' 2 95 0.0 7 5.0 42" RCP Line H at Station 2 +50 Location: 8 -3' 42" RCP Line H at Station 2 +50 123.1 9 -2' 42" RCP Line H at Station 2 +50 123.6 Wet Moisture Dry Test Lift # / Mr. Rick O'Dell (1 -cc copy) Density Content Density No. Depth Location (pcf) % (pcf) 1 -5' 24" Storm Drain Line H at Station 122.4 17.5 104.2 99.5 Pass 4 +50 1 +0.7 98.0 2 -4' 24" Storm Drain Line H at Station 121.2 17.8 102.9 4 +50 3 -3' 24" Storm Drain Line H at Station 121.7 17.6 103.5 4 +50 4 -2' 24" Storm Drain Line H at Station 120.7 18.1 102.2 17.6 103.9 19.8 101.1 20.1 102.5 17.9 104.4 16.9 105.7 17.3 104.1 Proctor Number Spec. No. 4 +50 Percent Proctor Density 5 -1' 24" Storm Drain Line H at Station 122.2 98.1 Pass 4 +50 1 6 -5' 42" RCP Line H at Station 2 +50 121.1 7 -4' 42" RCP Line H at Station 2 +50 123.1 8 -3' 42" RCP Line H at Station 2 +50 123.1 9 -2' 42" RCP Line H at Station 2 +50 123.6 10 -1' 42" RCP Line H at Station 2 +50 122.1 Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Pass Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. 1 17.6 103.9 19.8 101.1 20.1 102.5 17.9 104.4 16.9 105.7 17.3 104.1 Proctor Number Spec. No. Moisture Deviation Percent Proctor Density Pass Fail 148639 -1 1 +0.9 98.1 Pass 148639 -1 1 +1.2 96.9 Pass 148639 -1 1 +1.0 97.5 Pass 148639 -1 1 +1.5 96.2 Pass 148639 -1 1 +1.0 97.8 Pass 148639 -1 1 +3.2 95.2 Pass 148639 -1 1 +3.5 96.5 Pass 148639 -1 1 +1.3 98.3 Pass 148639 -1 1 +0.3 99.5 Pass 148639 -1 1 +0.7 98.0 Pass Respectfully Submitted, Alliance Geotechnical Group Perry C. Kak a, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Consulting Engineering * Geotechnical Engineering * Construction Materials hwnric 3228 Halifax Street, Suite A, Dallas, Texas 75247 GEOTECH ICfiL Phone: (972) 444 -8889 Fax: (972) 444 -8893 GROUH Acct ID: 1770 File No: C13 -0634 Date Sampled: 01/22/2014 Report Date: 01/29/2014 Sampled By: Roberts, Duce Project: West Sandy Lake Road By Order Of: Walter Location: Various Locations Order Number: 1770 Client: City of Coppell REPORT: Nuclear Field Density Test LAB NO: 157241 Test Method: See Below TEST RESULTS Report No: 157241 Page 2 of 2 Location: CONFORMS Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. K kara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Wet Moisture Dry Percent Test Lift # / Density Content Density Proctor Spec. Moisture Proctor Pass No. Depth Location (pcf) % (pcf) Number No. Deviation Density Fail 11 -7' 8x4 RCP Line G at Station 1 +50 123.4 18.4 104.2 148639 -1 1 +1.8 98.1 Pass 12 -6' 8x4 RCP Line G at Station 1 +50 123.2 18.7 103.8 148639 -1 1 +2.1 97.7 Pass 13 -5' 8x4 RCP Line G at Station 1 +50 122.9 19.0 103.3 148639 -1 2 +2.4 97.3 Pass 14 -4' 8x4 RCP Line G at Station 1 +50 122.9 19.4 102.9 148639 -1 2 +2.8 96.9 Pass 15 -3' 8x4 RCP Line G at Station 1 +50 123.2 18.8 103.7 148639 -1 2 +2.2 97.6 Pass 16 -2' 8x4 RCP Line G at Station 1 +50 123.3 18.0 104.5 148639 -1 2 +1.4 98.4 Pass 17 -1' 8x4 RCP Line G at Station 1 +50 123.3 17.7 104.8 148639 -1 2 +1.1 98.7 Pass 18 . -2' Retest of Test #13 taken 1 -16 -14 128.7 14.8 112.1 148639 -2 2 +2.8 96.7 Pass 19 -1' Retest of Test #14 taken 1 -16 -14 128.6 14.1 112.7 148639 -2 2 +2.1 97.2 Pass 20 -3' Retest of Test #15 taken 1 -16 -14 129.7 14.7 113.1 148639 -2 2 +2.7 97.6 Pass 21 -2' Retest of Test #16 taken 1 -16 -14 130.9 15.3 113.5 148639 -2 2 +3.3 97.9 Pass 22 -1' Retest of Test #17 taken 1 -16 -14 131.0 15.1 113.8 148639 -2 2 +3.1 98.2 Pass Gauge No.: 2287 Daily Standard Counts: 01/22/2014 DS: 2846 MS: 448 Remarks: All locations and depths are approximate. AGG did not observe backfill operations. Test Methods: ASTM D6938 -10 CONFORMS Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. K kara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.