Loading...
Gateway BP(2.5)-LR140205. L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Client: Duke Realty Report No.: 466909 14241 Dallas Parkway Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/31/2014 Report Date: 02/05/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density Gauge Serial No: 36438 Current: 703 Current: 2278 Test Mode: DT Previous: 710 Previous: 2292 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 466297 Brown / Clay 22.2 100.7 Optimum +4 95 min FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (% max) Paving 1 150' south of west entrance 6" 466297 22.5 119.2 97.3 97 Paving 2 75' south of west entrance 6" 466297 22.3 121.6 99.4 99 Paving 3 West entrance 6" 466297 22.0* 110.8 90.8 90* An asterisk ( *) appears next to results which do NOT meet the project specifications. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (S B/S W) Page 1 of 2 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Pacheco Koch Consulting Engineers Attn: Mr. Clayton Strolle 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec Cooper Excavation Attn: Mr. Ric Linnebur 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Report No.: 466909 Project No.: 1318601 Date of Service: 01/31/2014 Report Date: 02/05/2014 Technician: Rick Smith Started: 05:OOpm Finished: 06:45pm Rone Engineering K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (S B/S W) Page 2 of 2 . L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Client: Duke Realty Report No.: 467031 14241 Dallas Parkway Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/31/2014 Report Date: 02/05/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density Gauge Serial No: 36438 Current: 703 Current: 2278 Test Mode: DT Previous: 710 Previous: 2292 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 463863 Reddish Brown / Clayey Sand 13.5 114.9 -2/ +2 95 min Test No Test Location Building pad select 1 Grid lines E/4.5, 1st lift Building pad select 2 Grid lines E /3, 1st lift Building pad select 3 Grid lines E/11.5, 1st lift Building pad select 4 Grid lines G/1.5, 1st lift Building pad select 5 Grid lines G /3, 1 st lift Building pad select 6 Grid lines G/4.5, 1st lift Building pad select 7 Retest #3 above FIELD DENSITY TESTS Probe M/D Depth No. 6" 463863 6" 463863 6" 463863 6" 463863 6" 463863 6" 463863 6" 463863 Moisture Wet Density Dry Density Density % (pcf) (pcf) (% max) 12.6 125.0 111.0 97 13.4 126.7 111.7 97 15.8* 124.5 107.5 94* 15.1 125.9 109.4 95 12.5 129.1 114.8 100 10.9* 122.5 110.5 96 12.0 122.3 109.2 95 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (S B/S W) Page 1 of 3 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing FIELD DENSITY TESTS Report No.: 467031 Project No.: 1318601 Date of Service: 01/31/2014 Report Date: 02/05/2014 Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (% max) Building pad select 8 Retest #6 above 6" 463863 14.1 127.4 111.7 97 An asterisk (") appears next to results which do NOT meet the project specifications. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (S B/S W) Page 2 of 3 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Pacheco Koch Consulting Engineers Attn: Mr. Clayton Strolle 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec Cooper Excavation Attn: Mr. Ric Linnebur 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Report No.: 467031 Project No.: 1318601 Date of Service: 01/31/2014 Report Date: 02/05/2014 Technician: Rick Smith Rone Engineering See Report 466909 for technician time K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (S B/S W) Page 3 of 3 . L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Client: Duke Realty Report No.: 467030 14241 Dallas Parkway Moisture Density Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/31/2014 Report Date: 02/05/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density Gauge Serial No: 36438 Current: 703 Current: 2278 Test Mode: DT Previous: 710 Previous: 2292 MOISTURE DENSITY RELATIONS Moisture M/D No. Description % 464630 Dark Brown / Clay 27.6 FIELD DENSITY TESTS Test Probe M/D No Test Location Depth No. Building pad 1 Grid lines A/13, 2' below grade 6" 464630 Building pad 2 Grid lines A/11.5, 2' below grade 6" 464630 Maximum Density Project Requirements (pcf) Moisture Density 90.7 Minimum +4 92 -96 Moisture Wet Density Dry Density Density % (pcf) (pcf) (% max) 34.5 113.0 84.0 93 34.7 112.6 83.6 92 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (SW/SW) Page 1 of 2 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Pacheco Koch Consulting Engineers Attn: Mr. Clayton Strolle 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec Cooper Excavation Attn: Mr. Ric Linnebur 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Report No.: 467030 Project No.: 1318601 Date of Service: 01/31/2014 Report Date: 02/05/2014 Technician: Rick Smith Rone Engineering See Report 466909 for technician time K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (SW/SW) Page 2 of 2