Loading...
Gateway BP(2.5)-LR140210. L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: Duke Realty Report No.: 466908 Cylinder Maximum 14241 Dallas Parkway Project No.: 1318601 Strength Fracture Dallas, TX 75254 (psi) Type 1 1 02/07/2014 7 6.00 28.27 102,320 3,620 Type 2 Date of Service: 01/31/2014 Report Date: 02/10/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring PROJECT DATA Contractor: Mix Design I.D.: 80K11521 Measured Concrete Supplier: Redi -Mix Placement Date: 01/31/2014 Slump Plant: P136 Weather Conditions: Clear (inches) Specification Requirements Time Sampled: 11:50am Batch time: 10:52am 6.25 Strength: 3,500 psi @ 28 days Temperature - Air: 50 °F Concrete: 60 °F Slump (in.): 5" - 7" Truck No: 1007 Ticket No: 25795529 Air ( %): NA Air Content: NA Unit Weight (pcf): NA Test Method: ASTM C -172 Overall Placement Location: ASTM C -31 (except 10.1.2) Piers 47, 48, 49, 50, 51, 42, 43, 44, 45, 46, 41, 118 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 Sample Location: ASTM C -1231 Pier 51 N=110]:i9101a9 *1K Concrete Compressive Cylinder 6" x 12" 28 Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in 2) (lbs) (psi) Type 1 1 02/07/2014 7 6.00 28.27 102,320 3,620 Type 2 2 02/28/2014 28 3 02/28/2014 28 4 03/28/2014 56 FIXI X11 r :::I R I d .:l 17-1 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /SW) Page 1 of 2 n e Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 NII��N Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: Duke Realty Report No.: 466908 14241 Dallas Parkway Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/31/2014 Report Date: 02/10/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon Technician: Rick Smith Rone Engineering See Report 466907 for technician time K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /SW) Page 2 of 2