Loading...
Gateway BP(2.5)-LR140128. L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Drilled Pier Inspection Report of Inspection D rille r: Auger D rillin g 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Drilled Pier Inspection Report No.: 466557 Project No.: 1318601 Date of Service: 01/24/2014 Report Date: 01/28/2014 Pier Identification #215 #216 #217 #218 #219 Pier Diameter (in) 24 24 24 24 24 Depth of Pier From Surface (ft) 38.20 37.20 37.40 37.80 39.70 Depth of Bearing Stratum From Surface (ft) 29.00 28.00 28.60 29.00 30.60 Required Penetration (ft) 8.00 8.00 8.00 8.00 8.00 Actual Penetration (ft)* 9.20 9.20 8.80 8.80 9.10 Condition of Bottom (wet /dry) D ry D ry D ry D ry D ry Plumb Within Tolerance (yes /no) Yes Yes Yes Yes Yes Casing Diameter (in) /Casing Length (ft) 26 /29 26 /28 26 /28 26 /29 26 /30.6 NumberofBars /Reinforcing Bar Size 6 / #6 6 / #6 6 / #6 6 / #6 6 / #6 Length of Reinforcing Steel (ft) 38.30 37.00 37.50 38.00 39.80 Time Drilling was Completed (am /pm) 10:30 AM 12:00 PM 2:00 PM 3:00 PM 4:00 PM Time Concrete was Placed (am /pm) 2:00 PM 2:20 PM 2:45 PM 3:25 PM N/A Depth of Pier From Top of Concrete (ft) 38.80 37.70 38.00 38.40 40.30 E levatio n : S u rface (ft) ** 97.40 97.50 97.40 97.40 97.40 Elevation: Top of Pier (ft) ** 98.00 98.00 98.00 98.00 98.00 Elevation: Bottom of Pier (ft) ** 59.20 60.30 60.00 59.60 57.70 Elevation: Top of Bearing Stratum (ft.) ** 68.40 69.50 68.80 68.40 66.80 Bearing Stratum (description) Gray Shale Note: See Report# 466558 for Compressive Strength Test Specimens. *Additional Penetration not requested unless noted. * *Elevation by others LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (S W/S W) Page 1 of 3 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Drilled Pier Inspection D rille r: Auger D rillin g 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Drilled Pier Inspection Report No.: 466557 Project No.: 1318601 Date of Service: 01/24/2014 Report Date: 01/28/2014 Pier Identification #220 Pier Diameter (in) 24 Depth of Pier From Surface (ft) 39.00 Depth of Bearing Stratum From Surface (ft) 30.00 Required Penetration (ft) 8.00 Actual Penetration (ft)* 9.00 Condition of Bottom (wet /dry) Dry Plumb Within Tolerance (yes /no) Yes Casing Diameter(in) /Casing Length (ft) 26/30 NumberofBars /Reinforcing Bar Size 6 / #6 Length of Reinforcing Steel (ft) 39.20 Time Drilling was Completed (am /pm) 4:45 PM Time Concrete was Placed (am /pm) 5:40 PM Depth of Pier From Top of Concrete (ft) 39.70 E le v a do n: Surface (ft) ** 97.30 Elevation: Top of Pier (ft) ** 98.00 E le v a do n: Bottom of Pier (ft) ** 58.30 Elevation: Top of Bearing Stratum (ft.) ** 67.30 Bearing Stratum (description) Gray Shale Note: See Report# 466558 for Compressive Strength Test Specimens. * Additional Penetration not requested unless noted. * *Elevation by others LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (S W/S W) Page 2 of 3 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Drilled Pier Inspection Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Drilled Pier Inspection Report No.: 466557 Project No.: 1318601 Date of Service: 01/24/2014 Report Date: 01/28/2014 Technician: Rick Smith Started: 07:15am Finished: 06:30pm Rone Engineering K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (SW/SW) Page 3 of 3