Loading...
Gateway BP(2.5)-LR140128 (2). L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Client: Duke Realty Report No.: 466259 14241 Dallas Parkway Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/20/2014 Report Date: 01/28/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density Gauge Serial No: 36438 Current: 639 Current: 2341 Test Mode: DT Previous: 707 Previous: 2311 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 464630 Dark Brown / Clay 27.6 90.7 Optimum +4 95 min FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (% max) Paving 1 100' west, 25' south of northwest fire hydrant, 3' 6" 464630 29.0 116.2 90.1 99 below grade Paving 2 10' east, 25' south of northwest fire hydrant, 2.5' 6" 464630 30.6 115.3 88.3 97 below grade Paving 3 180' west, 25' south of northwest fire hydrant, 6" 464630 29.5 115.6 89.3 99 2.5' below grade Paving 4 320' north, 25' east of west entrance, 2' below 6" 464630 28.4 115.2 89.7 99 grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 1 of 2 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Pacheco Koch Consulting Engineers Attn: Mr. Clayton Strolle 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec Cooper Excavation Attn: Mr. Ric Linnebur 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Report No.: 466259 Project No.: 1318601 Date of Service: 01/20/2014 Report Date: 01/28/2014 Technician: Rick Smith Started: 05:OOpm Finished: 06:45pm Rone Engineering K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 2 of 2 . L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Client: Duke Realty Report No.: 466321 14241 Dallas Parkway Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/18/2014 Report Date: 01/28/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density Gauge Serial No: 36438 Current: 707 Current: 2311 Test Mode: DT Previous: 714 Previous: 2299 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 464630 Dark Brown / Clay 27.6 90.7 Minimum +4 92 -96 Test No Buidling Pad 1 Gridline C.4/12 Buidling Pad 2 Gridline C.1/12 Buidling Pad 3 Gridline C.7/12 Test Location FIELD DENSITY TESTS Probe M/D Depth No. 6" 464630 6" 464630 6" 464630 Moisture Wet Density Dry Density Density % (pcf) (pcf) (% max) 34.9 114.8 85.1 94 31.9 113.2 85.8 95 31.6 113.7 86.4 95 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 1 of 2 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Pacheco Koch Consulting Engineers Attn: Mr. Clayton Strolle 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec Cooper Excavation Attn: Mr. Ric Linnebur 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Report No.: 466321 Project No.: 1318601 Date of Service: 01/18/2014 Report Date: 01/28/2014 Technician: Rick Smith Rone Engineering See Report 466320 for technician time K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 2 of 2 . L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Client: Duke Realty Report No.: 466411 14241 Dallas Parkway Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/22/2014 Report Date: 01/28/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density Gauge Serial No: 36438 Current: 717 Current: 2306 Test Mode: DT Previous: 706 Previous: 2275 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 463863 Reddish Brown / Clayey Sand 13.5 114.9 -2/ +2 95 min Test No Test Location Building Pad Select 1 Gridline A.5/18.5, 1st lift Building Pad Select 2 Gridline A.5/16.5, 1st lift Building Pad Select 3 Gridline A.5/14.5, 1st lift Building Pad Select 4 Gridline B.8/14.5, 1st lift Building Pad Select 5 Gridline B.8/16.5, 1st lift Building Pad Select 6 Gridline B.8/18.5, 1st lift FIELD DENSITY TESTS Probe M/D Depth No. 6" 463863 6" 463863 6" 463863 6" 463863 6" 463863 6" 463863 Moisture Wet Density Dry Density Density % (pcf) (pcf) (% max) 11.6 125.6 112.5 98 11.8 123.6 110.6 96 12.6 123.6 109.8 96 15.5 129.1 111.8 97 11.5 125.3 112.4 98 13.2 132.6 117.1 102 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 1 of 2 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Pacheco Koch Consulting Engineers Attn: Mr. Clayton Strolle 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec Cooper Excavation Attn: Mr. Ric Linnebur 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Report No.: 466411 Project No.: 1318601 Date of Service: 01/22/2014 Report Date: 01/28/2014 Technician: Rick Smith Started: 04:OOpm Finished: 05:45pm Rone Engineering K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 2 of 2 . L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Client: Duke Realty Report No.: 466524 14241 Dallas Parkway Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/23/2014 Report Date: 01/28/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density Gauge Serial No: 36438 Current: 697 Current: 2293 Test Mode: DT Previous: 717 Previous: 2306 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 464630 Dark Brown / Clay 27.6 90.7 Minimum +4 92 -96 Test No Test Location Building Pad 1 Gridline E/12, 2' below grade Building Pad 2 Gridline E/9.5, 2' below grade Building Pad 3 Gridline E /7, 2' below grade Building Pad 4 Gridline E/5.5, 2' below grade Building Pad 5 Gridline E /3, 2' below grade Building Pad 6 Gridline E/1.5, 2' below grade FIELD DENSITY TESTS Probe M/D Depth No. 6" 464630 6" 464630 6" 464630 6" 464630 6" 464630 6" 464630 Moisture Wet Density Dry Density Density % (pcf) (pcf) (% max) 32.8 113.0 85.1 94 32.3 112.6 85.1 94 31.9 114.5 86.8 96 31.8 112.2 85.1 94 34.2 114.1 85.0 94 32.3 112.7 85.2 94 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 1 of 2 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Pacheco Koch Consulting Engineers Attn: Mr. Clayton Strolle 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec Cooper Excavation Attn: Mr. Ric Linnebur 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Report No.: 466524 Project No.: 1318601 Date of Service: 01/23/2014 Report Date: 01/28/2014 Technician: Rick Smith Started: 03:30pm Finished: 05:15pm Rone Engineering K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 2 of 2 . L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Client: Duke Realty Report No.: 466412 14241 Dallas Parkway Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/22/2014 Report Date: 01/28/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density Gauge Serial No: 36438 Current: 717 Current: 2306 Test Mode: DT Previous: 706 Previous: 2275 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 464630 Dark Brown / Clay 27.6 90.7 Minimum +4 92 -96 FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (% max) Building Pad 1 Gridline F.5/7.5, 2' below grade 6" 464630 32.2 112.5 85.1 94 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 1 of 2 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Pacheco Koch Consulting Engineers Attn: Mr. Clayton Strolle 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec Cooper Excavation Attn: Mr. Ric Linnebur 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Report No.: 466412 Project No.: 1318601 Date of Service: 01/22/2014 Report Date: 01/28/2014 Technician: Rick Smith Rone Engineering See Report 466411 for technician time K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 2 of 2 . L= FFF 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Client: Duke Realty Report No.: 466259 14241 Dallas Parkway Project No.: 1318601 Dallas, TX 75254 Date of Service: 01/20/2014 Report Date: 01/28/2014 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density Gauge Serial No: 36438 Current: 639 Current: 2341 Test Mode: DT Previous: 707 Previous: 2311 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 464630 Dark Brown / Clay 27.6 90.7 Optimum +4 95 min FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (% max) Paving 1 100' west, 25' south of northwest fire hydrant, 3' 6" 464630 29.0 116.2 90.1 99 below grade Paving 2 10' east, 25' south of northwest fire hydrant, 2.5' 6" 464630 30.6 115.3 88.3 97 below grade Paving 3 180' west, 25' south of northwest fire hydrant, 6" 464630 29.5 115.6 89.3 99 2.5' below grade Paving 4 320' north, 25' east of west entrance, 2' below 6" 464630 28.4 115.2 89.7 99 grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 1 of 2 . L= FFF Client: Duke Realty 14241 Dallas Parkway Dallas, TX 75254 Project: BMSC - Naterra 1250 S. Freeport Parkway Coppell, Texas Services: Perform In -Place Density Testing Report Distribution: Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce (1 -ec copy) 1 -ec Rone Engineering Project Managers Attn: Mr. Scott Watson, CET 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Redi -Mix Concrete Attn: Redi Mix 1 -ec BMSC Naterra Attn: Mr. Ralph Novak 1 -ec Pacheco Koch Consulting Engineers Attn: Mr. Clayton Strolle 1 -ec Engineering Analyst Attn: Mr. Steve Burns 1 -ec Cooper Excavation Attn: Mr. Ric Linnebur 1 -ec AECC, Inc. Attn: Attn: Wesley White 1 -ec Beauty Manufacturing Solutions Corp. Attn: Mr. Ralph Novak 1 -ec Duke Realty Attn: Mr. Rob VanDame 1 -ec Duke Realty Attn: Mr. Bruce Dillon 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In -Place Density Testing Report No.: 466259 Project No.: 1318601 Date of Service: 01/20/2014 Report Date: 01/28/2014 Technician: Rick Smith Started: 05:OOpm Finished: 06:45pm Rone Engineering K. Scott Watson, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (HJ /S W) Page 2 of 2