Gateway BP(2.5)-LR140128 (2). L= FFF
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Client: Duke Realty
Report No.: 466259
14241 Dallas Parkway
Project No.: 1318601
Dallas, TX 75254
Date of Service: 01/20/2014
Report Date: 01/28/2014
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
PROJECT DATA
Contractor:
Standard Counts
Test Method: ASTM D -6938 Gauge: Troxler 3430
Moisture Density
Gauge Serial No: 36438
Current: 639 Current: 2341
Test Mode: DT
Previous: 707 Previous: 2311
MOISTURE DENSITY RELATIONS
Maximum
Moisture
Density Project Requirements
M/D No. Description %
(pcf) Moisture Density
464630 Dark Brown / Clay 27.6
90.7 Optimum +4 95 min
FIELD DENSITY TESTS
Test Probe M/D Moisture Wet Density Dry Density Density
No Test Location Depth No.
% (pcf) (pcf) (% max)
Paving
1 100' west, 25' south of northwest fire hydrant, 3' 6" 464630
29.0 116.2 90.1 99
below grade
Paving
2 10' east, 25' south of northwest fire hydrant, 2.5' 6" 464630
30.6 115.3 88.3 97
below grade
Paving
3 180' west, 25' south of northwest fire hydrant, 6" 464630
29.5 115.6 89.3 99
2.5' below grade
Paving
4 320' north, 25' east of west entrance, 2' below 6" 464630
28.4 115.2 89.7 99
grade
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 1 of 2
. L= FFF
Client: Duke Realty
14241 Dallas Parkway
Dallas, TX 75254
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
Report Distribution:
Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce
(1 -ec copy)
1 -ec Rone Engineering Project Managers
Attn: Mr. Scott Watson, CET
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Redi -Mix Concrete Attn: Redi Mix
1 -ec BMSC Naterra Attn: Mr. Ralph Novak
1 -ec Pacheco Koch Consulting Engineers
Attn: Mr. Clayton Strolle
1 -ec Engineering Analyst Attn: Mr. Steve Burns
1 -ec Cooper Excavation Attn: Mr. Ric Linnebur
1 -ec AECC, Inc. Attn: Attn: Wesley White
1 -ec Beauty Manufacturing Solutions Corp.
Attn: Mr. Ralph Novak
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Duke Realty Attn: Mr. Bruce Dillon
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Report No.: 466259
Project No.: 1318601
Date of Service: 01/20/2014
Report Date: 01/28/2014
Technician: Rick Smith Started: 05:OOpm Finished: 06:45pm Rone Engineering
K. Scott Watson, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 2 of 2
. L= FFF
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Client: Duke Realty Report No.: 466321
14241 Dallas Parkway Project No.: 1318601
Dallas, TX 75254
Date of Service: 01/18/2014
Report Date: 01/28/2014
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
PROJECT DATA
Contractor: Standard Counts
Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density
Gauge Serial No: 36438 Current: 707 Current: 2311
Test Mode: DT Previous: 714 Previous: 2299
MOISTURE DENSITY RELATIONS
Maximum
Moisture Density Project Requirements
M/D No. Description % (pcf) Moisture Density
464630 Dark Brown / Clay 27.6 90.7 Minimum +4 92 -96
Test
No
Buidling Pad
1 Gridline C.4/12
Buidling Pad
2 Gridline C.1/12
Buidling Pad
3 Gridline C.7/12
Test Location
FIELD DENSITY TESTS
Probe
M/D
Depth
No.
6"
464630
6"
464630
6"
464630
Moisture
Wet Density
Dry Density
Density
%
(pcf)
(pcf)
(% max)
34.9
114.8
85.1
94
31.9
113.2
85.8
95
31.6
113.7
86.4
95
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 1 of 2
. L= FFF
Client: Duke Realty
14241 Dallas Parkway
Dallas, TX 75254
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
Report Distribution:
Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce
(1 -ec copy)
1 -ec Rone Engineering Project Managers
Attn: Mr. Scott Watson, CET
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Redi -Mix Concrete Attn: Redi Mix
1 -ec BMSC Naterra Attn: Mr. Ralph Novak
1 -ec Pacheco Koch Consulting Engineers
Attn: Mr. Clayton Strolle
1 -ec Engineering Analyst Attn: Mr. Steve Burns
1 -ec Cooper Excavation Attn: Mr. Ric Linnebur
1 -ec AECC, Inc. Attn: Attn: Wesley White
1 -ec Beauty Manufacturing Solutions Corp.
Attn: Mr. Ralph Novak
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Duke Realty Attn: Mr. Bruce Dillon
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Report No.: 466321
Project No.: 1318601
Date of Service: 01/18/2014
Report Date: 01/28/2014
Technician: Rick Smith Rone Engineering
See Report 466320 for technician time
K. Scott Watson, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 2 of 2
. L= FFF
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Client: Duke Realty Report No.: 466411
14241 Dallas Parkway Project No.: 1318601
Dallas, TX 75254
Date of Service: 01/22/2014
Report Date: 01/28/2014
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
PROJECT DATA
Contractor: Standard Counts
Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density
Gauge Serial No: 36438 Current: 717 Current: 2306
Test Mode: DT Previous: 706 Previous: 2275
MOISTURE DENSITY RELATIONS
Maximum
Moisture Density Project Requirements
M/D No. Description % (pcf) Moisture Density
463863 Reddish Brown / Clayey Sand 13.5 114.9 -2/ +2 95 min
Test
No
Test Location
Building Pad Select
1 Gridline A.5/18.5, 1st lift
Building Pad Select
2 Gridline A.5/16.5, 1st lift
Building Pad Select
3 Gridline A.5/14.5, 1st lift
Building Pad Select
4 Gridline B.8/14.5, 1st lift
Building Pad Select
5 Gridline B.8/16.5, 1st lift
Building Pad Select
6 Gridline B.8/18.5, 1st lift
FIELD DENSITY TESTS
Probe
M/D
Depth
No.
6"
463863
6"
463863
6"
463863
6"
463863
6"
463863
6"
463863
Moisture
Wet Density
Dry Density
Density
%
(pcf)
(pcf)
(% max)
11.6
125.6
112.5
98
11.8
123.6
110.6
96
12.6
123.6
109.8
96
15.5
129.1
111.8
97
11.5
125.3
112.4
98
13.2
132.6
117.1
102
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 1 of 2
. L= FFF
Client: Duke Realty
14241 Dallas Parkway
Dallas, TX 75254
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
Report Distribution:
Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce
(1 -ec copy)
1 -ec Rone Engineering Project Managers
Attn: Mr. Scott Watson, CET
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Redi -Mix Concrete Attn: Redi Mix
1 -ec BMSC Naterra Attn: Mr. Ralph Novak
1 -ec Pacheco Koch Consulting Engineers
Attn: Mr. Clayton Strolle
1 -ec Engineering Analyst Attn: Mr. Steve Burns
1 -ec Cooper Excavation Attn: Mr. Ric Linnebur
1 -ec AECC, Inc. Attn: Attn: Wesley White
1 -ec Beauty Manufacturing Solutions Corp.
Attn: Mr. Ralph Novak
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Duke Realty Attn: Mr. Bruce Dillon
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Report No.: 466411
Project No.: 1318601
Date of Service: 01/22/2014
Report Date: 01/28/2014
Technician: Rick Smith Started: 04:OOpm Finished: 05:45pm Rone Engineering
K. Scott Watson, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 2 of 2
. L= FFF
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Client: Duke Realty Report No.: 466524
14241 Dallas Parkway Project No.: 1318601
Dallas, TX 75254
Date of Service: 01/23/2014
Report Date: 01/28/2014
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
PROJECT DATA
Contractor: Standard Counts
Test Method: ASTM D -6938 Gauge: Troxler 3430 Moisture Density
Gauge Serial No: 36438 Current: 697 Current: 2293
Test Mode: DT Previous: 717 Previous: 2306
MOISTURE DENSITY RELATIONS
Maximum
Moisture Density Project Requirements
M/D No. Description % (pcf) Moisture Density
464630 Dark Brown / Clay 27.6 90.7 Minimum +4 92 -96
Test
No
Test Location
Building Pad
1 Gridline E/12, 2' below grade
Building Pad
2 Gridline E/9.5, 2' below grade
Building Pad
3 Gridline E /7, 2' below grade
Building Pad
4 Gridline E/5.5, 2' below grade
Building Pad
5 Gridline E /3, 2' below grade
Building Pad
6 Gridline E/1.5, 2' below grade
FIELD DENSITY TESTS
Probe
M/D
Depth
No.
6"
464630
6"
464630
6"
464630
6"
464630
6"
464630
6"
464630
Moisture
Wet Density
Dry Density
Density
%
(pcf)
(pcf)
(% max)
32.8
113.0
85.1
94
32.3
112.6
85.1
94
31.9
114.5
86.8
96
31.8
112.2
85.1
94
34.2
114.1
85.0
94
32.3
112.7
85.2
94
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 1 of 2
. L= FFF
Client: Duke Realty
14241 Dallas Parkway
Dallas, TX 75254
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
Report Distribution:
Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce
(1 -ec copy)
1 -ec Rone Engineering Project Managers
Attn: Mr. Scott Watson, CET
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Redi -Mix Concrete Attn: Redi Mix
1 -ec BMSC Naterra Attn: Mr. Ralph Novak
1 -ec Pacheco Koch Consulting Engineers
Attn: Mr. Clayton Strolle
1 -ec Engineering Analyst Attn: Mr. Steve Burns
1 -ec Cooper Excavation Attn: Mr. Ric Linnebur
1 -ec AECC, Inc. Attn: Attn: Wesley White
1 -ec Beauty Manufacturing Solutions Corp.
Attn: Mr. Ralph Novak
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Duke Realty Attn: Mr. Bruce Dillon
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Report No.: 466524
Project No.: 1318601
Date of Service: 01/23/2014
Report Date: 01/28/2014
Technician: Rick Smith Started: 03:30pm Finished: 05:15pm Rone Engineering
K. Scott Watson, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 2 of 2
. L= FFF
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Client: Duke Realty
Report No.: 466412
14241 Dallas Parkway
Project No.: 1318601
Dallas, TX 75254
Date of Service: 01/22/2014
Report Date: 01/28/2014
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
PROJECT DATA
Contractor:
Standard Counts
Test Method: ASTM D -6938
Gauge: Troxler 3430
Moisture Density
Gauge Serial No: 36438
Current: 717 Current: 2306
Test Mode: DT
Previous: 706 Previous: 2275
MOISTURE DENSITY RELATIONS
Maximum
Moisture
Density Project Requirements
M/D No. Description %
(pcf) Moisture Density
464630 Dark Brown / Clay
27.6
90.7 Minimum +4 92 -96
FIELD DENSITY TESTS
Test
Probe M/D Moisture Wet Density Dry Density Density
No Test Location
Depth No.
% (pcf) (pcf) (% max)
Building Pad
1 Gridline F.5/7.5, 2' below grade
6" 464630
32.2 112.5 85.1 94
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 1 of 2
. L= FFF
Client: Duke Realty
14241 Dallas Parkway
Dallas, TX 75254
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
Report Distribution:
Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce
(1 -ec copy)
1 -ec Rone Engineering Project Managers
Attn: Mr. Scott Watson, CET
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Redi -Mix Concrete Attn: Redi Mix
1 -ec BMSC Naterra Attn: Mr. Ralph Novak
1 -ec Pacheco Koch Consulting Engineers
Attn: Mr. Clayton Strolle
1 -ec Engineering Analyst Attn: Mr. Steve Burns
1 -ec Cooper Excavation Attn: Mr. Ric Linnebur
1 -ec AECC, Inc. Attn: Attn: Wesley White
1 -ec Beauty Manufacturing Solutions Corp.
Attn: Mr. Ralph Novak
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Duke Realty Attn: Mr. Bruce Dillon
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Report No.: 466412
Project No.: 1318601
Date of Service: 01/22/2014
Report Date: 01/28/2014
Technician: Rick Smith Rone Engineering
See Report 466411 for technician time
K. Scott Watson, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 2 of 2
. L= FFF
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Client: Duke Realty
Report No.: 466259
14241 Dallas Parkway
Project No.: 1318601
Dallas, TX 75254
Date of Service: 01/20/2014
Report Date: 01/28/2014
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
PROJECT DATA
Contractor:
Standard Counts
Test Method: ASTM D -6938 Gauge: Troxler 3430
Moisture Density
Gauge Serial No: 36438
Current: 639 Current: 2341
Test Mode: DT
Previous: 707 Previous: 2311
MOISTURE DENSITY RELATIONS
Maximum
Moisture
Density Project Requirements
M/D No. Description %
(pcf) Moisture Density
464630 Dark Brown / Clay 27.6
90.7 Optimum +4 95 min
FIELD DENSITY TESTS
Test Probe M/D Moisture Wet Density Dry Density Density
No Test Location Depth No.
% (pcf) (pcf) (% max)
Paving
1 100' west, 25' south of northwest fire hydrant, 3' 6" 464630
29.0 116.2 90.1 99
below grade
Paving
2 10' east, 25' south of northwest fire hydrant, 2.5' 6" 464630
30.6 115.3 88.3 97
below grade
Paving
3 180' west, 25' south of northwest fire hydrant, 6" 464630
29.5 115.6 89.3 99
2.5' below grade
Paving
4 320' north, 25' east of west entrance, 2' below 6" 464630
28.4 115.2 89.7 99
grade
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 1 of 2
. L= FFF
Client: Duke Realty
14241 Dallas Parkway
Dallas, TX 75254
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Perform In -Place Density Testing
Report Distribution:
Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce
(1 -ec copy)
1 -ec Rone Engineering Project Managers
Attn: Mr. Scott Watson, CET
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Redi -Mix Concrete Attn: Redi Mix
1 -ec BMSC Naterra Attn: Mr. Ralph Novak
1 -ec Pacheco Koch Consulting Engineers
Attn: Mr. Clayton Strolle
1 -ec Engineering Analyst Attn: Mr. Steve Burns
1 -ec Cooper Excavation Attn: Mr. Ric Linnebur
1 -ec AECC, Inc. Attn: Attn: Wesley White
1 -ec Beauty Manufacturing Solutions Corp.
Attn: Mr. Ralph Novak
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Duke Realty Attn: Mr. Bruce Dillon
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of In -Place Density Testing
Report No.: 466259
Project No.: 1318601
Date of Service: 01/20/2014
Report Date: 01/28/2014
Technician: Rick Smith Started: 05:OOpm Finished: 06:45pm Rone Engineering
K. Scott Watson, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(HJ /S W)
Page 2 of 2