Gateway BP(2.5)-LR140129 (2). L= FFF
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Client: Duke Realty
Report No.: 466258
14241 Dallas Parkway
Project No.: 1318601
Dallas, TX 75254
P136
Specification Requirements
Date of Service: 01/20/2014
Strength:
Report Date: 01/29/2014
Project: BMSC - Naterra
5" - 7"
1250 S. Freeport Parkway
N/A
Coppell, Texas
ASTM C -172
Services: Obtain samples of fresh concrete at the placement
locations, perform required testing, cast compressive strength samples and bring
PROJECT DATA
Contractor:
80K11521
Concrete Supplier:
Redi Mix
Plant:
P136
Specification Requirements
Slump
Strength:
3,500 psi @ 28 days
Slump (in.):
5" - 7"
Air ( %):
N/A
Test Method:
ASTM C -172
68 °F
ASTM C -31 (except 10.1.2)
ASTM C -143
1130
ASTM C -231
ASTM C -1064
NA
ASTM C -138
ASTM C -1231
Mix Design I.D.:
80K11521
Cylinder Maximum
Measured
Placement Date:
01/20/2014
Set No. Tested (days) (in) (in 2) (lbs)
Slump
Weather Conditions: Clear
3,790 Type 2
(inches)
Time Sampled:
01:45pm
Batch time: 12:46pm
5.75
Temperature - Air:
68 °F
Concrete: 60 °F
Truck No:
1130
Ticket No: 25789427
Air Content:
NA
Unit Weight (pcf): NA
Overall Placement Location:
Piers: #299, #293, #294, #304, #305, #306, #307, and #308
Sample Location:
#304
N=110]:i9101a9 *1K
Concrete Compressive Cylinder 6" x 12"
28
Cylinder Maximum
Compressive
Marked Date Age Diameter Area Load
Strength Fracture
Set No. Tested (days) (in) (in 2) (lbs)
(psi) Type
1 1 01/27/2014 7 6.00 28.27 107,070
3,790 Type 2
2 02/17/2014
28
3 02/17/2014
28
4 03/17/2014
56
FIXI X11 r :::I R I d .:l 17-1
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(S B/S W)
Page 1 of 2
n e Engineering 8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
NII��N Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Client: Duke Realty Report No.: 466258
14241 Dallas Parkway Project No.: 1318601
Dallas, TX 75254
Date of Service: 01/20/2014
Report Date: 01/29/2014
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
Report Distribution:
Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce
(1 -ec copy)
1 -ec Rone Engineering Project Managers
Attn: Mr. Scott Watson, CET
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Engineering Analyst Attn: Mr. Steve Burns
1 -ec BMSC Naterra Attn: Mr. Ralph Novak
1 -ec Beauty Manufacturing Solutions Corp.
Attn: Mr. Ralph Novak
1 -ec Redi -Mix Concrete Attn: Redi Mix
1 -ec AECC, Inc. Attn: Attn: Wesley White
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Duke Realty Attn: Mr. Bruce Dillon
Technician: Rick Smith Rone Engineering
K. Scott Watson, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(S B/S W)
Page 2 of 2
. L= FFF
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Client: Duke Realty
Report No.: 466158
14241 Dallas Parkway
Project No.: 1318601
Dallas, TX 75254
P236
Specification Requirements
Date of Service: 01/17/2014
Strength:
Report Date: 01/29/2014
Project: BMSC - Naterra
5" - 7"
1250 S. Freeport Parkway
NA
Coppell, Texas
ASTM C -172
Services: Obtain samples of fresh concrete at the placement
locations, perform required testing, cast compressive strength samples and bring
PROJECT DATA
Contractor:
Measured
Concrete Supplier:
Redi -Mix
Plant:
P236
Specification Requirements
5.0
Strength:
3,500 psi @ 28 days
Slump (in.):
5" - 7"
Air ( %):
NA
Test Method:
ASTM C -172
ASTM C -31 (except 10.1.2)
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -1231
Mix Design I.D.: 80K11521
Placement Date: 01/17/2014
Weather Conditions: Clear
Time Sampled: 11:30am
Temperature - Air: 48 °F
Truck No: 1192
Air Content: NA
Overall Placement Location:
Pier #'s 297, 298, 300, 301, 302, 303
Sample Location:
Pier #298
N=110]:i9101a9 *1K
Concrete Compressive Cylinder 6" x 12"
Measured
Cylinder Maximum
Slump
Marked Date Age Diameter Area Load
(inches)
Batch time: 10:12am
5.0
Concrete: 50 °F
3,960 Type 2
Ticket No: 25788148
Unit Weight (pcf): NA
Concrete Compressive Cylinder 6" x 12"
28
Cylinder Maximum
Compressive
Marked Date Age Diameter Area Load
Strength Fracture
Set No. Tested (days) (in) (in 2) (lbs)
(psi) Type
1 1 01/24/2014 7 6.00 28.27 111,980
3,960 Type 2
2 02/14/2014
28
3 02/14/2014
28
4 03/14/2014
56
FIXI X11 r :::I R I d .:l 17-1
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM /SW)
Page 1 of 2
n e Engineering 8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
NII��N Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Client: Duke Realty Report No.: 466158
14241 Dallas Parkway Project No.: 1318601
Dallas, TX 75254
Date of Service: 01/17/2014
Report Date: 01/29/2014
Project: BMSC - Naterra
1250 S. Freeport Parkway
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
Report Distribution:
Orig: Duke Realty (Dallas, TX) Attn: Mr. Brian Pierce
(1 -ec copy)
1 -ec Rone Engineering Project Managers
Attn: Mr. Scott Watson, CET
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Engineering Analyst Attn: Mr. Steve Burns
1 -ec BMSC Naterra Attn: Mr. Ralph Novak
1 -ec Beauty Manufacturing Solutions Corp.
Attn: Mr. Ralph Novak
1 -ec Redi -Mix Concrete Attn: Redi Mix
1 -ec AECC, Inc. Attn: Attn: Wesley White
1 -ec Duke Realty Attn: Mr. Rob VanDame
1 -ec Duke Realty Attn: Mr. Bruce Dillon
Technician: Rick Smith Rone Engineering
K. Scott Watson, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM /SW)
Page 2 of 2