CONCRETE COMPRESSIVE STRENGTH TEST REPORT
CLIENT: City of Coppell
816 South Coppell Road
Coppell!, Texas 75019
PROJECT: Southern Belle Drive Reconstruction
PROJECT NO.:
DC 1315060
REPORT NO:
C5
INSPECTION DATE:
2 -15 -14
REPORT DATE:
2 -24 -14
Page I of I
PROPERTIES OF FRESH CONCRETE SAMPLING DATA
Specification
Field
Date Sampled
2 -15 -14
Requirement
Measure
Time Sampled
1 1:18 AM
Date
Age
Diameter
Yards Batched
Maximum
Air Temp. (F7 >50
Air Temp. (F °)
54
Time Batched
10:35 AM
Concrete Temp. (F' <95
Concrete Temp. (F'
59
Truck No.
8025
Slump (in.) <4
Slump (in.)
7*
Ticket No.
2103628
Air Content by Vol. ( %) 3 -6%
Air Content by Vol. ( %)
6.5*
Yards Placed
10
Water /Cement Ratio -
Water /Cement Ratio
-
Cylinders Molded
4
Supplier: TXI /141
68,860
2440
Specified Strength @ 28 days:
3600 psi
Mix ID, 8272
3 -15 -14
28
Nominal Cylinder Size (in.):
6 x 12
Mix Data Sup. By:
Applicable ASTM Test Standards:
C31. C39, C 138, C 143,
Cylinders Made By: HVJ Associates, Inc.
28
6.00
28.27
0172. C173, C1064, C232
COMPRESSIVE STRENGTH TEST RESULTS
LOCATION: Sidewalk on North bound lane side, at STA 1 +00
* Test results meet project specifications, except those marked.
Remarks: Notified Derrick Thomas of test results
compression machine HVJ- 08030000048
Technician: Eric Vincent
Aaron Pulpaneck, Labo " Quality Manager
Texas Firm
Our letters and tepf4ts are for the exchuske use of the client 71ie use of our name must receive our prior written approval. Our letters and reports appl) only to the material(s)
tested and /or inspected and are not necessarily indicative of the qualities of apparently identical or similar material(-.) This report ma) ° not be reproduced, except in full„ without
ohe r nment of l M A�gnr;aree 1w
Results
Set Cyl.
Date
Age
Diameter
Area
Maximum
Compressive
Type of
Meet
No. No.
Tested
(Days)
(in.)
in 2'
Load (Ibs)
Strength (psi)
Fracture
Sec,
1 256
2 -22 -14
7
600
28.27
80,800
2860
3
N/A
1 257
2 -22 -14
7
6.00
28.27
68,860
2440
5
N/A
1 258
3 -15 -14
28
600
28.27
1 259
3 -15 -14
28
6.00
28.27
* Test results meet project specifications, except those marked.
Remarks: Notified Derrick Thomas of test results
compression machine HVJ- 08030000048
Technician: Eric Vincent
Aaron Pulpaneck, Labo " Quality Manager