CF-Fire Station 2-CS 961203December 3, 1996
Phillips Swager Associates
Mr. Richard Schoelerman
Boyd Construction
1110 W. Harris, Suite 126
Arlington, TX 76017
Re: Notice to Proceed
Coppell Fire Stations Nos. 2 and 3
PSA Project No. 4110.00
Dear Mr. Schoelerman:
At our November 27, 1996 meeting at the Station No. 2 jobsite with the City
Inspectors, Lee Stone informed me that your plumbing subcontractor drilled 8"
core holes through three grade beams for a 4" waste lateral. PSA took
measurements to locate these holes and based on our calculations the 2 -//8 bottom
reinforcing has been cut through. This being the case, these beams should be
removed and installed per the contract documents.
In the future, per Concrete Note No. 6, no openings shall be permitted through
beams unless shown on the structural drawings or reviewed by the structural
engineer.
If you have any questions regarding this matter, please do not hesitate to call.
Sincerely,
PHILLIPS SWAGER ASSOCIATES
Dirk M. Dalhausser, AIA
Associate
jls\lrs2-y5
pc: Chief Jimmy Godwin/C.F.D.
G~~,~d~L~nstmction
Greg Schon/PSA
Dec-02 96 ,('l-41A tMBF~ I-I~,~,INEERS INC / , q ~,~j ~/~.o r-.,..,~_
- P~inc~pals.
Gary P Ten Eyc~ PE
Jerry L. Barnett, P E
Joseph T. Pill.
Wan Y. Ts~, P.E.
~N EYCK. MERRI~' BARNE~ PI~
CONSULTING F N~ ,,NEERS
December 2, 1996
Mr. Dzrk Dalhausser, AIA
Phillips Swager Associates, Inc.
12404 Park Central Drive
Suite 240
Dallas, Texas 75251
Refer Coppell Fire Stations 2 and 3
TMBP Job ~96-097
Dear Dirk:
Per your fax dated I1/27/96 regarding 8" diameter Gore holes
through grade beams at three locations, we concur the bottom
reinforcing steel in the beams has probably been cut based on your
field measurements. These beams should be removed and installed
per contract documents.
If you have any questions regarding the above please do not
hesitate to contact me.
Sincerely,
TEN EYCK.MERRITT.BARNETT.PITT
Consulting Engineers, Inc.
Jerry L. Barnett., P.E.
Vice President
2301 NORTr4
SUI'TE ,405
DALLAS, TE XA~- Associate
(214) 87~ 230; Douglas
FAX (2141 87'
METAL STU~$
2-~ CONT. TOP
O.C. ~,.~.
I-~4 CO~T. [
SEE SPECS. --
:TED --
,L ~ ~ ~-~-
"'~. C~T. DOT. ~ ~'~;
~" C~T~
~'-2" ~
01