Coppell BC3-LR010510CONCRETE COMPRESSIVE STR~GTH TEST Report Number: 94001487.0038 Service Date: March 30, 2001 Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Project Number: 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 May 10, 2001 Charles Schwab 217 Wrangler Coppell, Texas 94001487 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 3:00pm Supplier: TXI Truck No: 210 Mix I.D. No.: 153 Plant: 41 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 4.7 Concrete Temperature,O F: 72 Ambient Temperature, o F: 66 Ticket No: 8265907 Sample Information sample Time: 4:00pm Technician: Jessie Tipton Weather Conditions: Partly cloudy, cool Accumulative Yards: 20 Placement Method: Pump Sample Locations: SW corner of column Placement Location: 4 Columns @ SW corner of bldg. Specification Test Method 5 Max ASTM C-143 3-6 ASTM C-172 ASTM C-39 Plastic Unit Weight, pcf: ~r t I ~ Laboratory Test Data ~, ~ Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) j/~, Tested (days) (lbs) (psi) 1 1 e.o0 ~/~ 04/06/2001 7 128,190 4,530 1 2 6.00 ~¢#~J 04/06/2001 7 128,620 4,550 / Average 4,540 1 3 6.00 ~,i~=ZI~ 28 141,030 4,990 1 4 6.00 04/27/200~,~8 139,460 4,930 Average 4,960 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Field Results Reported To: Supt. w/Const. Assoc. Technician: Jessie Tipton Report Distribution: (1) Constructors & Associates (1) City of Coppell - Constr. Insp. (1) City of Coppell - Bldg. Insp. Reviewed by: Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of I CONCRETE COMPRESSIVE ST~GTH TEST Report Number: 94001487.0039 Service Date: April 4, 2001 Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Project Number: 8901 carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 May 10, 2001 Charles Schwab 217 Wrangler Coppell, Texas 94001487 Material Information Specified Strength: 5000 psi @ 28 Days Batch Time: 1:25pm Supplier: TXI Truck No: 922 Mix I.D. No.: 153 Plant: 41 Ticket No: 2855004 Sample Information Sample Time: 2:52pm Technician: Eddie Elrod Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Sample Locations: F.9/0.1 Placement Location: Columns for screen wall W side F.5/0.1,0.5, 0.9, F.9/0.1 Field Test Data Test Result Specification Test Method Slump, inches: 5.25 5.0 Max ASTM C-143 Air Content, %: N/A ASTM C-172 Concrete Temperature,O F: 87 ASTM C-39 Ambient Temperature, o F: 82 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) I 1 6.00 04/11/2001 7 110,930 3,920 I 2 6.00 04/11/2001 7 109,180 3,860 Average 3,890 1 3 6.00 05/02/2001 28 144,000 5,090 1 4 6.00 05/02/2001 28 144,450 5,110 Average 5,100 Services - Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive strength samples. Technician: Eddie Elrod Report Distribution: (1) Constructors & Associates (1) City of Coppell - Constr. Insp. (1) City of Coppell - Bldg. Insp. Reviewed by: Eric J. Cleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of 1