Loading...
Coppell BC3-LR010323CONCRETE COMPRESSIVE S~NGTH TEST Report Number: 94001487.0020 Service Date: February 20, 2001 Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Project Number: 8~1 Ca~nter F~., Sure ~1~ Dallas, Texas 75247 (214) 630-1010 March 23, 2001 Charles Schwab 217 Wrangler Coppell, Texas 94001487 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 1:28pm Supplier: TXI Truck No: 561 Mix I.D. No.: 46 Plant: 31 Ticket No: 2828601 Sample Information Sample Time: 2:30pm Technician: Mike Shields Weather Conditions: Sunny, dry Accumulative Yards: 8 Placement Method: Direct discharge Sample Locations: Pier #9 Placement Location: Piers Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, 0 F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification Test Method 4.50 75 70 4-5 ASTM C-143 N/A ASTM C-172 ASTM C-39 Set Specimen Diameter Date No. ID (inches) Tested 1 I 6.00 02/27/2001 1 2 6.00 02/27/2001 1 3 6.00 03/20/2001 1 4 6.00 03/20/2001 Services - Age at Maximum Test Load (days) (lbs) Compressive Strength (psi) 7 113,930 4,030 7 111,940 3,960 Average 4,000 28 145,870 5,160 28 138,270 4,890 Average 5,030 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Mike Shields Report Distribution: (1) Constructors & Associates (1) City of Coppell - Constr. Insp. (1) City of Coppell - Bldg. Insp. Reviewed by: ¢E~J. Cleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, Or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. =-u.w~,-r,,-- Page I of 1 CONCRETE COMPRESSIVE S~NGTH TEST Report Number: 94001487.0021 Service Date: February 20, 2001 Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Project Number: 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 March 23, 2001 Charles Schwab 217 Wrangler Coppell, Texas 94001487 Material Information Specified Strength: 5000 psi @ 28 Days Batch Time: 11:28am Supplier: TXI Truck No: 541 Mix I.D. No.: 153 Plant: 31 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, 0 F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 2828376 Sample Information Sample Time: 12:25pm Technician: Mike Shields Weather Conditions: Sunny, dry Accumulative Yards: 10 Placement Method: Direct discharge Sample Locations: NE corner of pad Placement Location: West generator pad Result Specification Test Method 7.50 72 68 6-9 ASTM C-143 N/A ASTM 0-172 ASTM C-39 Set Specimen Diameter Date No. ID (inches) Tested 1 1 6.00 02/27/2001 1 2 6.00 02/27/2001 1 3 6.00 03/20/2001 1 4 6.00 03/20/2001 Services - Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 126,600 4,480 7 120,940 4,280 Average 4,380 28 159,730 5,650 28 169,000 5,980 Average 5,820 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Mike Shields Report Distribution: (1) Constructors & Associates (1) City of Coppell- Constr. Insp. (1) City of Coppell - Bldg. Insp. Reviewed by: Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1