Coppell BC3-LR010316CONCRETE COMPRESSIVE ST/I"~GTH TEST Report Number: 94001487.0026 Service Date: March 7, 2001 Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Project Number: ENGINEERING, INC.. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 March 16, 2001 Charles Schwab 217 Wrangler Coppell, Texas 94001487 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 1:38pm Supplier: TXI Truck No: 650 Mix I.D. No.: 46 Plant: 31 Ticket No: 2836782 Sample Information Sample Time: Technician: Weather Conditions: Accumulative Yards: Placement Method: Sample Locations: Placement Location: 2:30pm Jessie Tipton Clear, warm 10 Direct discharge See placement location Pier caps W & S of building Sample location: First pier cap on south side from E bldg. line Field Test Data Test Result Specification Test Method Slump, inches: 4.50 5.0 Max ASTM C-143 Air Content, %: N/A ASTM C-172 Concrete Temperature, O F: 70 ASTM C-39 Ambient Temperature, o F: 58 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 1 6.00 03/14/2001 7 97,570 3,450 1 2 6.00 03/14/2001 7 106,790 3,780 Average 3,620 1 3 04/04/2001 28 1 4 04/04/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jessie Tipton Report Distribution: (1) Oonstructors & Associates (1) City of Coppell - Constr. Insp. Reviewed by: (1) City of Coppell - Bldg. Insp. J~;;;lev~land, P.E. Senior Projet~ Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CONCRETE COMPRESSIVE STt~IGTH TEST Report Number: 94001487.0028 Service Date: March 8, 2001 Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Project Number: 89Ol Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 March 16, 2001 Charles Schwab 217 Wrangler Coppell, Texas 94001487 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:56am Supplier: TXI Truck No: 826 Mix I.D. No.: 8272 Plant: 31 Ticket No: 2837491 Sample Information Sample Time: 10:40am Technician: Albert Garcia Weather Conditions: Cloudy Accumulative Yards: 8 Placement Method: Direct discharge Sample Locations: From wall: 10' S Placement Location: Cyclone foundation Field Test Data Test Result Specification Test Method Slump, inches: 5.00 5 Max. ASTM C-143 Air Content, %: ASTM C-172 Concrete Temperature, o F: 66 ASTM C-39 Ambient Temperature, o F: 60 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 I 6.00 03/15/2001 7 85,870 3,040 1 2 6.00 03/15/2001 7 84,790 3,000 Average 3,020 1 3 04/05/2001 28 1 4 04/05/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Albert Garcia Report Distribution: (1) Constructors & Associates (1) City of Coppell - Constr. Insp. (1) City of Coppell- Bldg. Insp. Reviewed by: Eric J. C~evel,3nd, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of I o,~w~,~,~,,~