Loading...
Coppell BC3-LR010313CONCRETE COMPRESSIVE S'It~.NGTH TEST Report Number: 94001487.0024 Service Date: March 5, 2001 Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Client:  tl[report Date: ~~~ - Project: Project Number: ENGINEERING, lNG 8~1 ~nter F~., Su~e ~100 Dallas, Texas 75247 (214) 6~-1010 Mamh 13, 2001 Charles Schwab 217 Wrangler Coppell, Texas 94001487 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 11:51am Supplier: TXI Truck No: 650 Mix I.D. No.: 9741 Plant: 31 Field Test Data Ticket No: 2034158 Sample Information Sample Time: 12:40pm Technician: Chris Theriot Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Pump Sample Locations: See placement location Placement Location: Columns & pier caps @ south cooling tower Test Result Specification Test Method Slump, inches: 3.50 3-5' ASTM C-143 Air Content, %: N/A ASTM C-172 Concrete Temperature,° F: 54 ASTM C-39 Ambient Temperature, o F: 49 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 1 6.00 03/12/2001 7 136,700 4,830 1 2 6.00 03/1 2/2001 7 134,490 4,760 Average 4,800 1 3 04/02/2001 28 1 4 04/02/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Chris Theriot Report Distribution: (1) Constructors & Associates (1) City of Coppell - Constr. Insp. (1) City of Coppell - Bldg. Insp. Reviewed by: HBC En~ Eric J. Cleveland, P.E. _ Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 . CONCRETE COMPRESSIVE ST/""~NGTH TEST Report Number: 94001487.0012 Service Date: February 12, 2001 Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Project Number: 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 March 13, 2001 Charles Schwab 217 Wrangler Coppell, Texas 94001487 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 1:12pm Supplier: TXI Truck No: 35 Mix I.D. No.: 46 Plant: 31 Ticket No: 2825814 Sample Information Sample Time: 2:08pm Technician: Gerry Graham Weather Conditions: Mild, cloudy Accumulative Yards: 10 Placement Method: Direct discharge Sample Locations: 4, 6, 15 and 25 Placement Location: Piers Field Test Data Test Result Specification Test Method Slump, inches: 5.25 5-7 ASTM C-143 Air Content, %: N/A ASTM C-172 Concrete Temperature,° F: 65 ASTM C-39 Ambient Temperature, o F: 45 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 1 6.00 02/19/2001 7 83,220 2,940 1 2 6.00 02/19/2001 7 79,810 2,820 Average 2,880 1 3 6.00 03/12/2001 28 166,700 5,900 1 4 6.00 03/12/2001 28 163,560 5,780 Average 5,840 Services - Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive strength samples. Technician: Gerry Graham Report Distribution: (1) Constructors & Associates (1) City of Coppell - Constr. Insp. (1) City of Coppell - Bldg. Insp. Reviewed by: Eric J. Cleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1