Coppell BC3-LR010213REPORT OF REINFORCING S'~.L INSPECTION Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Service Date: Project Number: Report Number: 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 February 13, 2001 Charles Schwab 217 Wrangler Coppell, Texas February 6, 2001 94001487 94001487.0007 Services: Reinforcing steel inspection. On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for reinforcing steel inspection. Reinforcing steel inspection for this date was cancelled due to the contractor was not ready and was rescheduled for 02/07/01. Technician: Roy Montgomery Report Distribution: HBC~-~Engineering' Inc. (1) Constructors & Associates Reviewed by: ,~/'"'~, (1) City of Coppell - Constr. Insp. (1) City of Coppell - Bldg. Insp. P.E.. Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 ~,,,,~ FIELD DENSITY TESTING EN(.ilNEEItlNG, [NC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Service Date: Project Number: Report Number: February 13, 2001 Charles Schwab 217 Wrangler Coppell, Texas February 5, 2001 94001487 94001487.0005 Material Information Material Laboratory No. Test Method Descri,ption and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) ASTM D-698 Brown sandy clay 11.5 120.0 -2/+2% 95% Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) Cooling Tower Pad 29 12' W of Transformer, 6' S of Building Final 1 6 30 21' W of Transformer, 9' S of Building Final 1 6 31 18' E of Tranformer, 12' S of Building 1 st 1 6 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 13.3 117.8 98 12.1 116.8 97 12.7 115.7 96 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Gauge ID: 31787 Field Test Method:ASTM D2922, ASTM D3017 Field Results Reported To: Contractor Technician: Roy Montgomery Report Distribution: (1) Constructors & Associates (1) City of Coppell - Constr. Insp. (1) City of Coppell - Bldg. Insp. Reviewed bY: ~~C.~~~' ~~~ . -- Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated ~bove and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of 1 o,.sos,~*,c.,.,,w