Coppell BC3-LR010212FIELD DENSITY TESTING 8901 Carpenter Rwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Service Date: Project Number: Report Number: February 12, 2001 Charles Schwab 217 Wrangler Coppell, Texas February 2, 2001 94001487 94001487.0004 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. ASTM D-698 2. ASTM D-698 Brown sandy clay Gray sandy clay & reddish tan clayey sand 11.5 120.0 16.0 107.5 -2~2% 95% -1~3% 95% Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) Cooling Tower Pad 24 12' W of Transformer, 12' S of Building, S 1st 1 6 end of Building 25 21' W of Transformer, 9' S of Building, S 2nd 1 6 end of Building 26 24' W of Transformer, 6' S of Building, S 2nd 1 6 end of Building 27 33' W of Transformer, 15' S of Building, S 1st 1 6 end of Building 28 36' E of Transformer, 6' S of Building, S Final 2 6 end of Building Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 12.5 120.3 100 12.3 118.2 99 12.8 118.7 99 13.3 116.5 97 19.0 103.0 96 Comments: Test results on this report meet project specification, Services - Pedorm in-place density and moisture content tests to determine degree of compaction and material moisture condition. Gauge ID: 31787 Field Test Method:ASTM D2922, ASTM D3017 Field Results Reported To: Contractor Technician: Roy Montgomery Report Distribution: (1) Constructors & Associates (1) Oity of Coppell - Oonstr. Insp. (1) City of Coppell - Bldg. Insp. Reviewed by: ~'~J~ '""' {-~ric ~. Cle((e?nd, P.E. Senior ProjeCt Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FIELD DENSITY TESTING Client: Constructors & Associates Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Report Date: Project: Service Date: Project Number: Report Number: d~on ENGINEERING, INC 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 February 12, 2001 Charles Schwab 217 Wrangler Coppell, Texas January 31, 2001 94001487 94001487.0003 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 014870001 ASTM D-698 Gray sandy clay & reddish tan clayey sand 16.0 107.5 -1/+3% 95% Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) Cooling Tower Pad 18 10' S of Building, 21' E of W, S end of EG 1 6 26.2 * 95.7 89 * Building 19 12' S of Building, 33' E of W, S end of EG 1 6 28.0 * 95.9 89 * Building 20 9' S of Building, 45' E of W, S end of EG 1 6 25.8 * 96.3 90 * Building 21 Retest of #18 EG 1 6 19.0 102.7 96 22 Retest of #19 EG 1 6 18.8 102.3 95 23 Retest of #20 EG 1 6 18.5 103.0 96 Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. EG = existing grade Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Gauge ID: 31787 Field Test Method:ASTM D2922, ASTM D3017 Field Results Reported To: Contractor Technician: Roy Montgomery Report Distribution: (1) Constructors & Associates (1) City of Coppell - Constr. Insp. (1) City of Coppell - Bldg. Insp. Reviewed ~ering, Inc. by: "-"",/../" / ~ (~rio ,J. Oleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.