Loading...
Coppell BC3-LR010129LABORATORY COMPACTIO"~.HARACTERISTICS OF SOIL Date: Client: Constructors & Associates iect: Attn: Mike Donnelly 3333 Welborn St Suite 200 Dallas TX 75219 Material Information Contractor: Constructors & Assoc. Source of Material: On-site Proposed Use: Subgrade Service Date Project Numl Report Sample Sampled By: Sample Location: Sample Description: Laboratory Test Data Test Procedure: Test Method: Sample Preparation: Rammer Type: Maximum Dry Unit Weight, pcf: Optimum Water Content, %: 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 2001 Wrangler )eli, Texas January 23,2001 94OO1487 Ethem, P.G., A. Bulent NW corner of existing building Gray sandy clay & reddish tan clayey sand Result Specifications ASTM D-698 Liquid Limit: 38 ASTM D-698 Plastic Limit: 20 ASTM D-698 Plasticity Index: 18 ASTM D-698 % Passing #200: 107.5 % Passing #40: 16.0 Moisture Density Relations Zero Air Voids Curve for assumed specific gravity 2.65 / \ / \ Services- Moisture-Density Relations Report Distribution: (1) Constructors & Associates (1) City of Coppell - constr. Insp. (1) City of Coppell - Bldg. insp. Reviewed by:~ Eric J. Cleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessanly Indicative of the properties of other apparently sim#ar or identical materials. Page I of 1 ~