Loading...
Connell Skaggs-CS 870402POWELL&POWELL Engineers and Consultants RECEIVED APl) W. J. Powell P.E. -- 1925-1967 W. Llewellyn Powell P.E. Richard L. Powell P.E. J. Michael Milllcan P.E. Michael D. McKenzle April 2, 1987 P&P No. 3354-87-1-2 Connell Skaggs Addition Lots 1, 2 & 3 Ms. Shohre Daneshmand City of Coppell 255 Parkway Blvd. Coppell, TX. Dear Ms. Daneshmand: This letter is in response to your concerns expressed at the DRC Meeting on March 24 regarding Powell & Powell's proposed "sheet flow" drainage across the refer,need site. In reply we respectfully offer the following comm ,fits for your consideration: 1. During a 100 year storm event, the depth of flow at the center of the drainage I~ath' (q=70 CFSe) will be approximately 0.7 feet deep with a velocity of 4.4 feet per se,end. In contrast, based on the city subdivision ordinance, the City of Coppell would allow a maJor arterial street to be designed at a 5% grsde to convey 60 'CFS with a depth of flow at the gutter of 0.5 feet and a veloeity of 10.9 feet per second. It is our opinion that the proposed drainage condition on our site is much safer than the condition which would be allowed on the arterial street. 2. The contributing drainage area of the site runoff is relatively small (14 acres), and therefore the design storm event will begin and pass quickly (20 minutes±). 3. We feel that our design, which will allow the site runoff to be conveyed in a wide, slow moving manner, will cause much less erosion in the existing swale along the west property line than if the on-site runoff were to be collected into a storm sewer system and discharged at a concentrated point in the unprotected swale. 4. Upon the development of Lot 3 and the construction of a box culvert, extending south to north near the west property line of the site, the sheet flow will be collected in a series of combination curb-grate inlets which in turn will discharge directly into the top of the future box. Enclosed for your review are the following items: A nomograph for flow in triangular gutters (City of Fort Worth Drainage Manual) indicating the flow rate, depth and velocity of flow for a major arterial street on a 5% slope with one lane remaining open. 2. Calculations for the depth and velocity of flow in the front and rear of the site for the 100, 50, 25, and 10-year storm events. 3. Sections at the center of the proposed drainage path showing the relationship of existing, proposed and future grades in the area of the existing south/north swale. 3354b/0320 3988 North Central Expressway, Suite 1130 / Dallas, Texas 75204 / (214) 5224660 We trust that this information adequately responds overland drainage across the site. If you have any information, please contact James Koch of this office. to your concerns regarding the questions, or need any further Very sincerely, JMM:ck enclosure POWELL & POWELL J. Michael Millican Mr. Kevin White - Connell Development Co. Mr. Bill Stapp - Connell Development Co. Mr. Richard Watson - American Stores Properties, Inc. Ms. Ann Gunning -Powell & Powell 3354b/0320 POWELL & ,Pp'"~LL ENGINEERS & COI~.,aLTANTS 3988 N, Central Expwy. Suite 1130 DALLAS, TEXAS 75204 (214) 522-4660 SHEET NO. ~ CALCULATED BY ~ CHECKED BY OF DATE SCALE RECEIVED APR 0 2,1987 I"l, '1' 4- [(... 5, ~fi 3.~o PR00UCI'204-! ~lnc., Grot:on. Ma.~. 01471 POWELL & P.~,..LL ENGINEERS & COho0LTANTS 3988 N. Central Expwy. Suite 1130 DALLAS, TEXAS 75204 (214) 522-4660 SHEET NO, CALCULATED BY CHECKED BY SCALE OF DATE DATE ..... o. 5 ~. t~ 0/1 r3 -IOOOO 9000 8OO0 7000 &ODD 5000 4OO0 3000_ 20OO ~000 9O0 8OO 70o j 600 _~ 500 ~> 400 300 200 I00 '90 ~- 80 ~ 70 '-40 20 I0 RECEIVED APR 0 2 1987 I1 IS ROUGHNESS COEFFICIENT IN MANNING FORMUL& ~PROP~IATE TOMATERIAL IN BOTTOM OF CHANNEL ~ IS RECIPROCAL OF CROSS SLO~'E N[.E,E.c[ mR m ,,OCEED,NGS ,,AG ,,GE ,so. .01l ~/8,1~00 y.o. zz v 20 INSTRUCTIONS ~CT Z/n ~&TtO wrrH SLOP[ (S~ · NO CONNECT DISCHARGE(~.) WITH DEP*~ H(ye~ THESE TWO LINES MUST INTERSECT AT PIVOT LINE FOR COMPLETE SOCUTION. F0~ SH&LL0W V- ID 7 z S ~ .S S ~ .o? 05 C~ ol C) Sa'~Ja~ O CHANNEL AS SHOWN USE NOMOGR APH WITH T TO DETERMINE DISCHARGE qelN yoFOe TOTAL mS- -'-~------X-----J ' CHARGE IN ENTIRE SECTION O THEN USE HOMOGRAPH TO DETERMINE QblN SECTION b FOR DEPTH JO .08 .O5 .OI 0 _, - .008 - .oo7 co : .oo6 uJ .005 bJ - r'~ .OO4 0 ,003 ,002 -.OOI ~'~ TO DETERMINE DIS- ~ y' CHARGE IN COMPOSITE SECTION FOLLOW ~- ~i INSTRUCTION 3. TO O~TAIN DISCHARGE IN SECTION O &T ASSUM[O ~ ~ ' - - ' DEPTH ~ OBTAIN OkFOR SLO~ ~aTIO E k &ND DEPTH yl THEN ~, (DEVELOPED BY U.S. BUREAU OF PUBLIC ROaOS -2.0 -80 - .70 -- .60 - .40 '-.ao .20 . .10 · .03 .02 .01 NOMOGRAPH FOR.FLOW IN TRIANGULAR GUTTERS III-6 IFIGURE ]]]:-I