Loading...
2013_0709City of Coppell The following form must be completed for each assembly tested. A signed and dated original must be submitted to the public water supplier for record keeping purposes: BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT Name of PWS: PWS I.D. #: 500 Southwestern * P. O. Box 94786 * Coppell, Texas 75019 972 - 304 -3509 * Recorder: 972-304-3518 * Fax: 972 - 304 -3514 Name of Business Douglas Buol 9 Residential ❑ Commercial Address of Assembly: 826 Chalfont Place ❑ Domestic 9 Irrigation ❑ Fireline The backflow prevention assembly detailed below has been tested and maintained as required by TCEQ (Formerly TNRCC) regulations and is certified to be operating within acceptable parameters. TYPE OF ASSEMBLY ❑ Reduced Pressure Principle ❑ Reduced Pressure Principle- Detector 0 Double Check Valve ❑ Double Check - Detector ❑ Pressure Vacuum Breaker ❑ Spill Resistant Pressure Vacuum Breaker f Ir Manufacturer: k6L-c Size: Model Number: 5�Sb Serial Number: 40 135`�_f Located At: ✓� Is the assembly installed in accordance with manufacturer recommendations and /or local codes? c, S Remarks: The above is certified to be true at the time of testing. Tester signature: Test gauge used: Make /Model Apollo 40- 200 -TK5U SN:_01111194 Calibration Date:_6/10/2013 Firm Name: .01 Accuracy Backflow Certified Tester (print): Terry Sitgreaves Firm Address: 9990 Barton Circle, Frisco TX 75035 Cert. Tester No. BP0014573 Exp. Date 6/12/15 Firm Phone #: 972.699.7156 Test Date -7 -9 "13 *TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS * *USE ONLY MANUFACTURER'S REPLACEMENT PARTS Reduced Pressure Principle Assembl Pressure Vacuum Breaker Double Check Valve Assembly Air Inlet Check Valve 1S check 2" check Relief Valve Opened at _psid Held at Psid Initial Test Held at3 =Q psid Held at psid Opened at _psid Did not open ❑ Leaked ❑ Closed Tight ff Closed Tight W Did not open ❑ Leaked ❑ Leaked ❑ Repairs and Materials Used Test after Held at psid Held at psid Opened at _psid Opened at _psid Held at psid Repair Closed Tight ❑ Remarks: The above is certified to be true at the time of testing. Tester signature: Test gauge used: Make /Model Apollo 40- 200 -TK5U SN:_01111194 Calibration Date:_6/10/2013 Firm Name: .01 Accuracy Backflow Certified Tester (print): Terry Sitgreaves Firm Address: 9990 Barton Circle, Frisco TX 75035 Cert. Tester No. BP0014573 Exp. Date 6/12/15 Firm Phone #: 972.699.7156 Test Date -7 -9 "13 *TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS * *USE ONLY MANUFACTURER'S REPLACEMENT PARTS