The following form must be completed for each assembly tested. A signed and dated original must be
submitted to the public water supplier for record keeping purposes:
BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT
Name of PWS: PWS I.D. #:
500 Southwestern * P. O. Box 94786 * Coppell, Texas 75019
972- 304 -3509 * Recorder: 972-304,3518 * Fax: 972 - 304 -3514
Name of Business Jim Nottinger 0 Residential ❑ Commercial
Address of Assembly: 305 Pepperwood Street ❑ Domestic 9 Irrigation ❑ Fireline
The backflow prevention assembly detailed below has been tested and maintained as required by TCEQ (Formerly
TNRCC) regulations and is certified to be operating within acceptable parameters.
TYPE OF ASSEMBLY
❑ Reduced Pressure Principle ❑ Reduced Pressure Principle- Detector
Double Check Valve ❑ Double Check - Detector
❑ Pressure Vacuum Breaker ❑ Spill Resistant Pressure Vacuum Breaker
Manufacturer: V 1S Size:
Model Number: 35v Serial Number: A 23'74)(a2
Located At: front yard on irrigation
Is the assembly installed in accordance with manufacturer recommendations and/or local codes? ��
Remarks:
The above is certified to be true at the time of testing. Tester signature: _,f�Q
Test gauge used: Make /Model Apollo 40- 200 -TK5U SN:_01111194 Calibration Date:_6/10/2013
Firm Name: .01 Accuracy Backflow Certified Tester (print): Terry Sitgreaves
Firm Address: 9990 Barton Circle, Frisco TX 75035 Cert. Tester No. BP0014573 Exp. Date 6112/15
Firm Phone #: 972.699.7156 Test Date &—Z-(-1)
*TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS
* *USE ONLY MANUFACTURER'S REPLACEMENT PARTS
Reduced Pressure Principle Assembly
Pressure Vacuum Breaker
Double Check Valve Assembly
Air Inlet
Check Valve
15 check
2 nd check
Relief Valve
Opened at psid
Held at psid
Initial Test
Held at 2155 psid
Held at "U psid
Opened at_psid
Did not open ❑
Leaked ❑
Closed Tight PD
Closed Tight 0'
Did not open ❑
Leaked ❑
Leaked ❑
Repairs and
Materials
Used
Test after
Held at psid
Held at psid
Opened at _psid
Opened at _psid
Held at psid
Repair
I Closed Tight ❑
Remarks:
The above is certified to be true at the time of testing. Tester signature: _,f�Q
Test gauge used: Make /Model Apollo 40- 200 -TK5U SN:_01111194 Calibration Date:_6/10/2013
Firm Name: .01 Accuracy Backflow Certified Tester (print): Terry Sitgreaves
Firm Address: 9990 Barton Circle, Frisco TX 75035 Cert. Tester No. BP0014573 Exp. Date 6112/15
Firm Phone #: 972.699.7156 Test Date &—Z-(-1)
*TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS
* *USE ONLY MANUFACTURER'S REPLACEMENT PARTS