2013_0621City of Coppell The following form must be completed for each assembly tested. A signed and dated original must be submitted to the public water supplier for record keeping purposes: BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT Name of PWS: PWS I.D. #: 500 Southwestern * P. O. Box 94786 * Coppell, Texas 75019 972- 304 -3509 * Recorder: 972-304,3518 * Fax: 972 - 304 -3514 Name of Business Jim Nottinger 0 Residential ❑ Commercial Address of Assembly: 305 Pepperwood Street ❑ Domestic 9 Irrigation ❑ Fireline The backflow prevention assembly detailed below has been tested and maintained as required by TCEQ (Formerly TNRCC) regulations and is certified to be operating within acceptable parameters. TYPE OF ASSEMBLY ❑ Reduced Pressure Principle ❑ Reduced Pressure Principle- Detector Double Check Valve ❑ Double Check - Detector ❑ Pressure Vacuum Breaker ❑ Spill Resistant Pressure Vacuum Breaker Manufacturer: V 1S Size: Model Number: 35v Serial Number: A 23'74)(a2 Located At: front yard on irrigation Is the assembly installed in accordance with manufacturer recommendations and/or local codes? �� Remarks: The above is certified to be true at the time of testing. Tester signature: _,f�Q Test gauge used: Make /Model Apollo 40- 200 -TK5U SN:_01111194 Calibration Date:_6/10/2013 Firm Name: .01 Accuracy Backflow Certified Tester (print): Terry Sitgreaves Firm Address: 9990 Barton Circle, Frisco TX 75035 Cert. Tester No. BP0014573 Exp. Date 6112/15 Firm Phone #: 972.699.7156 Test Date &—Z-(-1) *TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS * *USE ONLY MANUFACTURER'S REPLACEMENT PARTS Reduced Pressure Principle Assembly Pressure Vacuum Breaker Double Check Valve Assembly Air Inlet Check Valve 15 check 2 nd check Relief Valve Opened at psid Held at psid Initial Test Held at 2155 psid Held at "U psid Opened at_psid Did not open ❑ Leaked ❑ Closed Tight PD Closed Tight 0' Did not open ❑ Leaked ❑ Leaked ❑ Repairs and Materials Used Test after Held at psid Held at psid Opened at _psid Opened at _psid Held at psid Repair I Closed Tight ❑ Remarks: The above is certified to be true at the time of testing. Tester signature: _,f�Q Test gauge used: Make /Model Apollo 40- 200 -TK5U SN:_01111194 Calibration Date:_6/10/2013 Firm Name: .01 Accuracy Backflow Certified Tester (print): Terry Sitgreaves Firm Address: 9990 Barton Circle, Frisco TX 75035 Cert. Tester No. BP0014573 Exp. Date 6112/15 Firm Phone #: 972.699.7156 Test Date &—Z-(-1) *TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS * *USE ONLY MANUFACTURER'S REPLACEMENT PARTS